scholarly journals Field distribution of a flux-concentration type linear induction motor

2001 ◽  
Vol 37 (4) ◽  
pp. 2841-2843 ◽  
Author(s):  
D. Roy ◽  
A. Fujiyoshi ◽  
S. Yamada ◽  
M. Iwahara
2000 ◽  
Vol 36 (5) ◽  
pp. 3555-3557 ◽  
Author(s):  
D. Roy ◽  
D. Saruhashi ◽  
S. Yamada ◽  
M. Iwahara

2000 ◽  
Vol 24 (4−2) ◽  
pp. 963-966
Author(s):  
D. Roy ◽  
D. Saruhashi ◽  
T. Maeda ◽  
S. Yamada ◽  
M. Iwahara

2013 ◽  
Vol 416-417 ◽  
pp. 408-417
Author(s):  
Jin Rao ◽  
Jin Xu ◽  
De Zhi Liu ◽  
Xi Dang Yang ◽  
Wei Ming Ma

For segment-powered linear induction motor (LIM), there is major asymmetry among the mutual inductance of stator windings. Based on magnetic motive force theory, this paper derived the magnetic motive force distribution of single-phase winding of the segment-powered linear induction motor, and confirmed the characteristics of magnetic motive force distribution of the segment-powered linear induction motor. Based on the magnetic motive force distribution of single-phase winding, the analytic expressions of air-gap field distribution of the segment-powered linear motor were derived, and the finite element simulation results verified the analytic results.