Application of Novel Electrical Aging Markers for Irradiated Low Voltage Nuclear Power Plant Power Cables

Author(s):  
Ehtasham Mustafa ◽  
Ramy S.A. Afia ◽  
Zoltan Adam Tamus
Author(s):  
Ehtasham Mustafa ◽  
Ramy S. A. Afia ◽  
Zoltán Ádám Tamus

Abstract This paper discusses the effect of thermal stress on the electrical properties, conduction and polarization, of low-voltage CSPE/XLPE-based power cables used in a nuclear power plant. The cables were subjected to an accelerated thermal stress at 120°C for an equivalent service period of 20, 40, 60 and 80 years. The capacitance, tanδ, resistivity at different frequencies and extended voltage response were the methods used for the investigation. A significant variation in the values of tanδ at low frequency, i.e., at 100 Hz, was observed. For the extended voltage response measurement, the decay voltage slope increased, showing the increase in the conduction particles inside the insulation material. While the decrease in return voltage slope showed that the slow polarization processes occurring at very low frequencies were decreased with aging. A strong correlation between the tanδ and decay voltage slope was also observed, which increased as the insulation aging increased. The results showed that the methods could be used for the in situ measurement of conduction and polarization phenomenon in the low-voltage cables, and hence helping in the assessment of the condition of cable insulation.


2014 ◽  
Author(s):  
Gregory Von White, II ◽  
John Lee. Schroeder ◽  
Patricia Sue. Sawyer ◽  
Derek Wichhart ◽  
Guillermo Adrian Mata ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document