Fuzzy-DE approach for the optimal placement of FACTS devices to relief congestion in a power system

Author(s):  
Biplab Bhattacharyya ◽  
Vikash Kumar Gupta ◽  
Sanjay Kumar
Author(s):  
Naraina Avudayappan ◽  
S.N. Deepa

Purpose The loading and power variations in the power system, especially for the peak hours have abundant concussion on the loading patterns of the open access transmission system. During such unconditional state of loading the transmission line parameters and the line voltages show a substandard profile, which depicts exaction of congestion management of the power line in such events. The purpose of this paper is to present an uncomplicated and economical model for congestion management using flexible AC transmission system (FACTS) devices. Design/methodology/approach The approach desires a two-step procedure, first by optimal placement of thyristor controlled series capacitor (TCSC) and static VAR compensator (SVC) as FACTS devices in the network; second tuning the control parameters to their optimized values. The optimal location and tuning of TCSC and SVC represents a hectic optimization problem, due to its multi-objective and constrained nature. Hence, a reassuring heuristic optimization algorithm inspired by behavior of cat and firefly is employed to find the optimal placement and tuning of TCSC and SVC. Findings The effectiveness of the proposed model is tested through simulation on standard IEEE 14-bus system. The proposed approach proves to be better than the earlier existing approaches in the literature. Research limitations/implications With the completed simulation and results, it is proved that the proposed scheme has reduced the congestion in line, thereby increasing the voltage stability along with improved loading capability for the congested lines. Practical implications The usefulness of the proposed scheme is justified with the computed results, giving convenience for implementation to any practical transmission network. Originality/value This paper fulfills an identified need to study exaction of congestion management of the power line.


Author(s):  
Mahmood Khalid Zarkani ◽  
Ahmed Sahib Tukkee ◽  
Mohammed Jasim Alali

<p>The rapid and enormous growths of the power electronics industries have made the flexible AC transmission system (FACTS) devices efficient and viable for utility application to increase power system operation controllability as well as flexibility. This research work presents the application of an evolutionary algorithm namely differential evolution (DE) approach to optimize the location and size of three main types of FACTS devices in order to minimize the power system losses as well as improving the network voltage profile. The utilized system has been reactively loaded beginning from the base to 150% and the system performance is analyzed with and without FACTS devices in order to confirm its importance within the power system. Thyristor controlled series capacitor (TCSC), unified power flow controller (UPFC) and static var compensator (SVC) are used in this research work to monitor the active and reactive power of the carried out system. The adopted algorithm has been examined on IEEE 30-bus test system. The obtained research findings are given with appropriate discussion and considered as quite encouraging that will be valuable in electrical grid restructuring.</p>


2015 ◽  
Vol 4 (1) ◽  
pp. 68-84 ◽  
Author(s):  
B. Venkateswara Rao ◽  
G.V. Nagesh Kumar

Modern electric power utilities are facing many challenges due to increasing power demand but the growth of power generation and transmission has been limited due to limited resources, environmental restrictions and right-of-way problems. These problems can be minimized by installing Flexible Alternating Current Transmission System (FACTS) devices in modern electric utilities to optimize the existing transmission system. Most effective use of the FACTS devices depend on the fact, how these devices are placed in the power system, i.e. the location and size. An optimal location and size of FACTS devices allows controlling its power flows and thus enhances the stability and reliability of the power systems. In this paper, Firefly Algorithm (FA) and BAT Algorithm (BAT) have been applied and compared to determine the optimal location and size of Static VAR Compensator (SVC) in a power system to improve voltage stability subjected to minimize the active power losses, fuel cost, branching loading and voltage deviation. The effectiveness of the proposed algorithms and improvement of power system stability has been demonstrated on IEEE 57 bus system using fast voltage stability index. The results obtained with variation of parameters of Firefly and BAT Algorithms has been studied and compared with Genetic Algorithm. The results are presented and analyzed.


2014 ◽  
Vol 984-985 ◽  
pp. 1286-1294
Author(s):  
R. Arun Prasath ◽  
M. Vimalraj ◽  
M. Riyas Ahamed ◽  
K. Srinivasa Rao

This paper presents a graphical user interface (GUI) uses Particle Swarm Optimization (PSO), which is used to find the optimal locations and sizing parameters of multi type Flexible AC transmission systems (FACTS) devices in complex power systems. The GUI toolbox, offers user to choose a power system network, PSO settings and the type and number of FACTS devices for the selected network. In this paper, three different FACTS devices are implemented: SVC, TCSC and TCPST. FACTS devices are used to increase the system loadability, by reducing power flow on overloaded lines, transmission line losses, improving system stability and security. With this can make the transmission system more energy-efficient. PSO used here for optimally allocating and sizing the multiple type FACTS in a standardized power network (IEEE 30 bus system) in order to improve voltage profile, minimizing power system total losses and maximizing system loadability with respect to the size of FACTS.


Sign in / Sign up

Export Citation Format

Share Document