Voltage Sag Study for a Practical Industrial Distribution Network

Author(s):  
Yan Li ◽  
Chengxiong Mao ◽  
Buhan Zhang ◽  
Jie Zeng
2012 ◽  
Vol 2012 ◽  
pp. 1-11 ◽  
Author(s):  
M. S. Ballal ◽  
H. M. Suryawanshi ◽  
T. Venkateswara Reddy

The basic power quality problems in the distribution network are voltage sag (dip), voltage flickering, and the service interruptions. STATCOM is a Flexible AC Transmission Systems (FACTS) technology device which can independently control the flow of reactive power. This paper presents the simulation and analysis of a STATCOM for voltage dip and voltage flickering mitigation. Simulations are carried out in MATLAB/Simulink to validate the performance of the STATCOM. A comparison between the six-pulse inverter and the five-level diode-clamped inverter is carried out for the performance of 66/11 KV distribution system.


2019 ◽  
Vol 8 (2S11) ◽  
pp. 3374-3379

This project work presents a proposed D-STATCOM system, Which is implemented in the distribution network. In the present scenario, the customer or consumer should be supplied with a quality power. The power quality issues like voltage sag, swell, lightning surges etc, can be reduced by using several advanced techniques. Among all these power quality issues voltage sag is considered and has been compensated in this project work by using D-STATCOM. The major advantage of D-STATCOM is that instead of installing the compensating device in the transmission and distribution line, the D-STATCOM unit is implemented at the consumers premises to maintain stable voltage for the connected electrical equipment’s and also to provide safe operation of the electrical equipment’s by extending their life time. The software ie., implemented by using MATLAB Simulink and the results are also verified experimentally by a hardware unit


2013 ◽  
Vol 391 ◽  
pp. 607-610 ◽  
Author(s):  
Yu Liu ◽  
Jin Hao Wang ◽  
Chao Ying Yang

To realize voltage sag source localization in distribution network, the paper proposes a function fitting method based on the least squares. Establish a voltage distance function in response to fault distance changes by the line voltage. According to the voltage distance function, combine with the bus voltage after fault to find out likely fault section and distance. Through the sorting algorithm to sort all possible results, weaken the effect of pseudo fault point on the judgment result. Finally the simulation verifies the effectiveness of the method.


Sign in / Sign up

Export Citation Format

Share Document