scholarly journals Scanning laser polarimetry and spectral domain optical coherence tomography for the detection of retinal changes in Parkinson's disease

2015 ◽  
Vol 93 (8) ◽  
pp. e672-e677 ◽  
Author(s):  
Birthe Stemplewitz ◽  
Matthias Keserü ◽  
Diana Bittersohl ◽  
Carsten Buhmann ◽  
Christos Skevas ◽  
...  
2010 ◽  
Vol 54 (6) ◽  
pp. 544-549 ◽  
Author(s):  
Suhwan Lee ◽  
Kyung Rim Sung ◽  
Jung Woo Cho ◽  
Mi Hyun Cheon ◽  
Sung Yong Kang ◽  
...  

Author(s):  
Mael Lever ◽  
Christian Halfwassen ◽  
Jan Darius Unterlauft ◽  
Nikolaos E. Bechrakis ◽  
Anke Manthey ◽  
...  

Abstract Purpose A central diagnostic tool in adult glaucoma is the peripapillary retinal nerve fibre layer (pRNFL) thickness. It can be assessed by scanning laser polarimetry (SLP) or optical coherence tomography (OCT). However, studies investigating the relevance of pRNFL measurements in children are rare. This study aims to compare the glaucoma diagnosing ability of SLP and OCT pRNFL thickness measurements in a paediatric population. Methods This retrospective study included 105 children (glaucoma: 22 (21.0%); healthy glaucoma suspects: 83 (79.0%)) aged 4–18 years, examined with SLP (GDxPro/ECC, Carl Zeiss Meditec) and spectral-domain OCT (SPECTRALIS®, Heidelberg Engineering). The thickness of pRNFL sectors was compared between diseased and healthy participants. Areas under the receiver-operating characteristic curves (AUC) and logistic regression results were used to compare the glaucoma discriminative capacity between SLP and OCT measurements. Results Using OCT, pRNFL thickness was decreased in the superior, nasal, and inferior quadrants of glaucoma patients compared to healthy controls (P < 0.001, each). With SLP, such a difference was only observed in the inferior quadrant (P = 0.011). A correlation between glaucoma diagnosis and OCT-measured pRNFL thickness was found in all quadrants (P < 0.001) other than the temporal. With SLP, a correlation was found for the total average thickness (P = 0.037) and inferior quadrant (P = 0.0019). Finally, the AUCs of OCT measurements were markedly higher than those of SLP (e.g., inferior quadrant: OCT 0.83, SLP 0.68). Conclusion pRNFL thickness measurements using both OCT and SLP, correlate notably with the presence of glaucoma. In general, the diagnostic performance of pRNFL thickness measurements seems higher for OCT than for SLP. Thus, pRNFL thickness measurements could provide important information, complementing conventional clinical and functional parameters in the diagnostic process of paediatric glaucoma.


Sign in / Sign up

Export Citation Format

Share Document