scholarly journals Knee Scores of Patients with Non‐Lateral Compartmental Knee Osteoarthritis Undergoing Mobile, Fixed‐Bearing Unicompartmental Knee and Total Knee Arthroplasties: A Randomized Controlled Trial

2021 ◽  
Author(s):  
Li‐ping Wu ◽  
Hermann O Mayr ◽  
Xing Zhang ◽  
Yuan‐qiao Huang ◽  
Yuan‐zhuang Chen ◽  
...  
2020 ◽  
Vol 102-B (11) ◽  
pp. 1511-1518
Author(s):  
Matthew S. Banger ◽  
William D. Johnston ◽  
Nima Razii ◽  
James Doonan ◽  
Philip J. Rowe ◽  
...  

Aims The aim of this study was to compare robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) in order to determine the changes in the anatomy of the knee and alignment of the lower limb following surgery. Methods An analysis of 38 patients who underwent TKA and 32 who underwent bi-UKA was performed as a secondary study from a prospective, single-centre, randomized controlled trial. CT imaging was used to measure coronal, sagittal, and axial alignment of the knee preoperatively and at three months postoperatively to determine changes in anatomy that had occurred as a result of the surgery. The hip-knee-ankle angle (HKAA) was also measured to identify any differences between the two groups. Results The pre- to postoperative changes in joint anatomy were significantly less in patients undergoing bi-UKA in all three planes in both the femur and tibia, except for femoral sagittal component orientation in which there was no difference. Overall, for the six parameters of alignment (three femoral and three tibial), 47% of bi-UKAs and 24% TKAs had a change of < 2° (p = 0.045). The change in HKAA towards neutral in varus and valgus knees was significantly less in patients undergoing bi-UKA compared with those undergoing TKA (p < 0.001). Alignment was neutral in those undergoing TKA (mean 179.5° (SD 3.2°)) while those undergoing bi-UKA had mild residual varus or valgus alignment (mean 177.8° (SD 3.4°)) (p < 0.001). Conclusion Robotic-assisted, cruciate-sparing bi-UKA maintains the natural anatomy of the knee in the coronal, sagittal, and axial planes better, and may therefore preserve normal joint kinematics, compared with a mechanically aligned TKA. This includes preservation of coronal joint line obliquity. HKAA alignment was corrected towards neutral significantly less in patients undergoing bi-UKA, which may represent restoration of the pre-disease constitutional alignment (p < 0.001). Cite this article: Bone Joint J 2020;102-B(11):1511–1518.


2018 ◽  
Vol 100-B (7) ◽  
pp. 925-929 ◽  
Author(s):  
M. P. Abdel ◽  
M. E. Tibbo ◽  
M. J. Stuart ◽  
R. T. Trousdale ◽  
A. D. Hanssen ◽  
...  

Aims It has been suggested that mobile-bearing total knee arthroplasty (TKA) might lead to better outcomes by accommodating some femorotibial rotational mismatch, thereby reducing contact stresses and polyethylene wear. The aim of this study was to determine whether there is a difference between fixed- and mobile-bearing versions of a contemporary TKA with respect to durability, range of movement (ROM) and function, ten years postoperatively. Patients and Methods A total of 240 patients who were enrolled in this randomized controlled trial (RCT) underwent a primary cemented TKA with one of three tibial components (all-polyethylene fixed-bearing, modular metal-backed fixed-bearing and mobile-bearing). Patients were reviewed at a median follow-up of ten years (IQR 9.2 to 10.4). Results There was no difference in durability, as measured by survivorship free of revision for any reason, nor in mean maximal ROM at ten years (p = 0.8). There was also no difference in function, as measured by Knee Society (KS) function scores (p = 0.63) or the prevalence of patellar tilt (p = 0.12). Conclusion In this clinical RCT, the mobile-bearing design of TKA was found to be reliable and durable, but did not provide better maximum knee flexion, function or durability ten years postoperatively compared with a posterior-stabilized, fixed-bearing design incorporating either an all-polyethylene or a modular-metal-backed tibial component. Cite this article: Bone Joint J 2018;100-B:925–9.


Author(s):  
Jörg Lützner ◽  
Franziska Beyer ◽  
Cornelia Lützner ◽  
Roman Riedel ◽  
Eric Tille

Abstract Purpose If substitution of the posterior cruciate ligament in total knee arthroplasty is necessary, there are two options available: posterior stabilized (PS) design with a post-cam mechanism or anterior-lipped ultracongruent (UC) inserts. UC inserts have the advantage that no femoral box is necessary and a standard femoral component can be used. The aim of this study was to compare the range of motion (ROM) and patient-reported outcome (PRO) after UC and PS fixed-bearing TKA. Better ROM in PS TKA and no difference in PRO between both designs was hypothesized. Methods A randomized controlled trial with 127 patients receiving a fixed-bearing UC or PS design of the same knee system was performed. Nine patients died and there were four revision surgeries. 107 patients completed the 5-year follow-up. Patient-reported outcome was assessed. Patellofemoral problems were evaluated using selected applicable questions of the Oxford Knee Score (getting up from a table, kneeling, climbing stairs). Results Surgical time was 10 min shorter in the UC group (p < 0.001). After 5 years, both groups demonstrated good knee function and health-related quality of life without significant differences between the groups. Both groups demonstrated a high satisfaction score and the majority of patients would undergo this surgery again. Patellofemoral problems were recognized more frequently in the PS group (p = 0.025). Conclusion Both designs demonstrated similar good results after 5 years. Stabilization with an anterior-lipped UC insert can be considered a safe alternative to the well-established PS design if cruciate substitution is necessary. Level of evidence 1.


Sign in / Sign up

Export Citation Format

Share Document