scholarly journals An In Vitro Model of Aortic Stenosis for the Assessment of Transcatheter Aortic Valve Implantation

2014 ◽  
Vol 136 (5) ◽  
Author(s):  
Hoda Maleki ◽  
Shahrokh Shahriari ◽  
Michel Labrosse ◽  
Philippe Pibarot ◽  
Lyes Kadem

A significant number of elderly patients with severe symptomatic aortic stenosis are denied surgical aortic valve replacement (SAVR) because of high operative risk. Transcatheter aortic valve implantation (TAVI) has emerged as a valid alternative to SAVR in these patients. One of the main characteristics of TAVI, when compared to SAVR, is that the diseased native aortic valve remains in place. For hemodynamic testing of new percutaneous valves and clinical training, one should rely on animal models. However, the development of an appropriate animal model of severe aortic stenosis is not straightforward. This work aims at developing and testing an elastic model of the ascending aorta including a severe aortic stenosis. The physical model was built based on a previous silicone model and tested experimentally in this study. Experimental results showed that the error between the computer-aided design (CAD) file and the physical elastic model was <5%, the compliance of the ascending aorta was 1.15 ml/mm Hg, the effective orifice area (EOA) of the stenotic valve was 0.86 cm2, the peak jet velocity was 4.9 m/s and mean transvalvular pressure gradient was 50 mm Hg, consistent with as severe. An EDWARDS-SAPIEN 26 mm valve was then implanted in the model leading to a significant increase in EOA (2.22 cm2) and a significant decrease in both peak jet velocity (1.29 m/s) and mean transvalvular pressure gradient (3.1 mm Hg). This model can be useful for preliminary in vitro testing of percutaneous valves before more extensive animal and in vivo tests.

Author(s):  
Akiko Masumoto ◽  
Takeshi Kitai ◽  
Mitsuhiko Ota ◽  
Kitae Kim ◽  
Natsuhiko Ehara ◽  
...  

Abstract Background Increasing number of symptomatic patients with severe aortic stenosis is treated with transcatheter aortic valve implantation (TAVI). Stroke is one of the most serious complications of TAVI, and the majority of cerebral events in patients undergoing TAVI have an embolic origin. Case summary A 90-year-old female underwent trans-femoral TAVI for symptomatic severe aortic stenosis. Just before the implantation of the transcatheter heart valve (THV), transoesophageal echocardiography (TOE) showed a mobile, high-echoic mass attached to the THV, which gradually enlarged to 26 mm, then spontaneously detached from the THV and flowed up the ascending aorta, disappearing from the TOE field of. After the procedure, the patient presented with ischaemic stroke. The patient’s stroke was thought to have resulted from the embolism migrating to the distal cerebral arteries. Discussion The detailed images acquired with TOE during TAVI enabled the prompt identification of the unusual intracardiac mass.


Sign in / Sign up

Export Citation Format

Share Document