An all-glass microfluidic flow cytometer

2021 ◽  
Author(s):  
Jiayu Li ◽  
Yuhan Cui ◽  
Zewen Wei ◽  
Tianfeng Zhou ◽  
Qin Li
CLEO: 2014 ◽  
2014 ◽  
Author(s):  
Kevin M. Dean ◽  
Lloyd M. Davis ◽  
Jennifer L. Lubbeck ◽  
Premashis Manna ◽  
Amy E. Palmer ◽  
...  

Lab on a Chip ◽  
2012 ◽  
Vol 12 (23) ◽  
pp. 5057 ◽  
Author(s):  
Joerg Martini ◽  
Michael I. Recht ◽  
Malte Huck ◽  
Marshall W. Bern ◽  
Noble M. Johnson ◽  
...  

2017 ◽  
Vol 20 (1) ◽  
Author(s):  
Koen de Wijs ◽  
Chengxun Liu ◽  
Bivragh Majeed ◽  
Karolien Jans ◽  
John M. O’Callaghan ◽  
...  

2010 ◽  
Vol 25 (6) ◽  
pp. 1509-1515 ◽  
Author(s):  
Segyeong Joo ◽  
Kee Hyun Kim ◽  
Hee Chan Kim ◽  
Taek Dong Chung

Lab on a Chip ◽  
2020 ◽  
Vol 20 (3) ◽  
pp. 655-664
Author(s):  
Yan Wang ◽  
Nima Sayyadi ◽  
Xianlin Zheng ◽  
Travis A. Woods ◽  
Robert C. Leif ◽  
...  

Time-resolved luminescence detection using long-lived probes with lifetimes in the microsecond region have shown great potential in ultrasensitive and multiplexed bioanalysis.


Author(s):  
Pouya Asrar ◽  
Nastaran Hashemi

We have shown the design and fabrication of a microfluidic flow cytometer. The microfluidic flow cytometer has been used to characterize microspheres of different sizes. The device is consisted of a microchannel, electronics, and integrated optics. The microchannel has three inlets. Two inlets are used to introduce sheath flows and one middle inlet is assigned as sample inlet. The sample flow is hydrodynamically focused at the center of the microchannel by two side streams (sheath flows). Also arrays of four chevron grooves compress the sample flow from the top and bottom of the microchannel. The core flow contains microspheres at a certain concentration. Detection of the microspheres at the interrogation region of the channel is performed by integrated optics and electronics. The scattered light emitted from the microspheres is collected by a multi-plex photo diode (MPPC). The results are recorded using data acquisition (DAQ) unit. The MPPCs employed in the setup is the new generation of photon counter devices with an excellent detection limit, a compact size, and capability of recording data at high gain compared to previous generation of photodetectors such as photomultipliers or avalanche photon diodes. The flow cytometer was sensitive enough to collect data from 3 μm microspheres using such mentioned sensitive photon counting unit. We have also used COMSOL Multiphysics software to investigate velocity and pressure distribution as well as concentration distribution along the microchannel. The average voltage collected by MPPC was 1.9 V for 10.2 μm and 1.6 V for 3.2 μm microsphere.


2018 ◽  
Vol 269 ◽  
pp. 382-387 ◽  
Author(s):  
Abdullah Bayram ◽  
Murat Serhatlioglu ◽  
Bulend Ortac ◽  
Serafettin Demic ◽  
Caglar Elbuken ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document