Quality assurance for a treatment planning system in scanned ion beam therapy

2000 ◽  
Vol 27 (7) ◽  
pp. 1588-1600 ◽  
Author(s):  
O. Jäkel ◽  
G. H. Hartmann ◽  
C. P. Karger ◽  
P. Heeg ◽  
J. Rassow
2013 ◽  
Vol 40 (5) ◽  
pp. 051722 ◽  
Author(s):  
D. Richter ◽  
A. Schwarzkopf ◽  
J. Trautmann ◽  
M. Krämer ◽  
M. Durante ◽  
...  

2013 ◽  
Vol 4 (1) ◽  
pp. 43-49
Author(s):  
M Jahangir Alam ◽  
Syed Md Akram Hussain ◽  
Kamila Afroj ◽  
Shyam Kishore Shrivastava

A three dimensional treatment planning system has been installed in the Oncology Center, Bangladesh. This system is based on the Anisotropic Analytical Algorithm (AAA). The aim of this study is to verify the validity of photon dose distribution which is calculated by this treatment planning system by comparing it with measured photon beam data in real water phantom. To do this verification, a quality assurance program, consisting of six tests, was performed. In this program, both the calculated output factors and dose at different conditions were compared with the measurement. As a result of that comparison, we found that the calculated output factor was in excellent agreement with the measured factors. Doses at depths beyond the depth of maximum dose calculated on-axis or off-axis in both the fields or penumbra region were found in good agreement with the measured dose under all conditions of energy, SSD and field size, for open and wedged fields. In the build up region, calculated and measured doses only agree (with a difference 2.0%) for field sizes > 5 × 5 cm2 up to 25 × 25 cm2. For smaller fields, the difference was higher than 2.0% because of the difficulty in dosimetry in that region. Dose calculation using treatment planning system based on the Anisotropic Analytical Algorithm (AAA) is accurate enough for clinical use except when calculating dose at depths above maximum dose for small field size.DOI: http://dx.doi.org/10.3329/bjmp.v4i1.14686 Bangladesh Journal of Medical Physics Vol.4 No.1 2011 43-49


2018 ◽  
Vol 17 (4) ◽  
pp. 441-446 ◽  
Author(s):  
Jalil ur Rehman ◽  
Muhammad Isa ◽  
Nisar Ahmad ◽  
H. M. Noor ul Huda Khan Asghar ◽  
Zaheer A. Gilani ◽  
...  

AbstractBackgroundAccurate three-dimensional dosimetry is essential in modern radiotherapy techniques such as volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). In this research work, the PRESAGE® dosimeter was used as quality assurance (QA) tool for VMAT planning for head and neck (H&N) cancer.Material and methodComputer tomography (CT) scans of an Image Radiation Oncology Core (IROC) H&N anthropomorphic phantom with both IROC standard insert and PRESAGE® insert were acquired separately. Both CT scans were imported into the Pinnacle (9.4 version) TPS for treatment planning, where the structures [planning target volume (PTV), organs at risk) and thermoluminescent detectors (TLDs) were manually contoured and used to optimise a VMAT plan. Treatment planning was done using VMAT (dual arc: 182°–178°, 178°–182°). Beam profile comparisons and gamma analysis were used to quantify agreement with film, PRESAGE® measurement and treatment planning system (TPS) calculated dose distribution.ResultsThe average ratio of TLD measured to calculated doses at the four PTV locations in the H&N phantom were between 0·95 to 0·99 for all three VMAT deliveries. Dose profiles were taken along the left–right, the anterior–posterior and superior–inferior axes, and good agreement was found between the PRESAGE® and Pinnacle profile. The mean value of gamma results for three VMAT deliveries in axial and sagittal planes were found to be 94·24 and 93·16% when compared with film and Pinnacle, respectively. The average values comparing the PRESAGE® results and dose values calculated on Pinnacle were observed to be 95·29 and 94·38% in the said planes, respectively, using a 5%/3 mm gamma criteria.ConclusionThe PRESAGE® dose measurements and calculated dose of pinnacle show reasonable agreement in both axial and sagittal planes for complex dual arc VMAT treatment plans. In general, the PRESAGE® dosimeter is found to be a feasible QA tool of VMAT plan for H&N cancer treatment.


Brachytherapy ◽  
2016 ◽  
Vol 15 (2) ◽  
pp. 252-262 ◽  
Author(s):  
Vasiliki Peppa ◽  
Evaggelos Pantelis ◽  
Eleftherios Pappas ◽  
Vasileios Lahanas ◽  
Constantinos Loukas ◽  
...  