scholarly journals When internal quality control is insufficient or inefficient: Consider patient-based real-time quality control!

Author(s):  
Huub H van Rossum
2020 ◽  
Vol 154 (Supplement_1) ◽  
pp. S91-S91
Author(s):  
J M Asinas

Abstract Introduction/Objective The management of internal quality control (IQC) in Sidra Medicine Clinical Chemistry Division has been evaluated in order to promote a more consolidated and efficient process of IQC management. The statistical data produced from Cerner QC Module are transferred to IQC review templates consisting of formulas to auto- calculate parameters such as multiple of expected QC failure frequency and desirable comparison limit between analyzers. The IQC review and documentation process using the in-house excel template requires several hours to complete, hence a faster and more efficient IQC management module is required. The main objective of this study is to improve the initial IQC management set up, work flow and review procedures and to implement Biorad Unity Real Time (URT) program to develop a more efficient IQC management system. Methods The URT software has been recently configured and implemented to consolidate and streamline IQC management. URT is built through Sidra Medicine IT Enterprise level which allows multiple users to login. IQC data are downloaded using scripts from Cerner which are filtered through Biorad Unity Connect (UC) software. Additional quality tools are also explored such as various user defined statistical reports, IQC analysis using peer reviewed total allowable error (TeA) and assignment of the most appropriate Westgard rules. Determination of sigma metrics and uncertainty of measurement is also performed using the URT application. Results The generation of any IQC report is less cumbersome and time consuming as compared with the previous process. However, some user defined formulas in the IQC templates are not found on the URT reports. The URT Levey Jennings chart are also more user friendly and directly compares the daily IQC data with Unity inter-laboratory peers enabling the production of instant and monthly reports through QCNet site when assay investigation is required and for IQC report documentation. Conclusion The combination of Cerner IQC, Unity Real-time, QCNet Inter-laboratory reports and in house IQC templates produce a high level and very detailed IQC review which effectively evaluate assay performance to assist on IQC troubleshooting and root cause analysis to be able to apply the most appropriate corrective actions.


2018 ◽  
Vol 33 (1) ◽  
pp. e22643 ◽  
Author(s):  
Huizhen Sun ◽  
Wei Wang ◽  
Haijian Zhao ◽  
Chuanbao Zhang ◽  
Falin He ◽  
...  

2021 ◽  
Vol 6 (2) ◽  
pp. 115-118
Author(s):  
Kafil Akhtar ◽  
Radhika Arora ◽  
Umrah Malik ◽  
Ankita Parashar ◽  
Murad Ahmad ◽  
...  

Quality control describes steps taken by blood and component bank to ensure that tests are performed correctly. Primary goal of quality control is transfusion of safe quality of blood. It is to ensure availability of efficient supply of blood and blood components. Internal quality control is the backbone of quality assurance program. To analyze the internal quality control of blood components in modern blood banking as an indicator of our blood bank performance. An observational cross sectional study conducted at the Blood and Component Bank, JN Medical College and Hospital from 2018 to 2020. Each blood component was arbitrarily chosen during the study on monthly basis. Selection criteria was 1.0% of total collection or minimum 4 bags per month. Packed red cells were evaluated for hemoglobin, hematocrit, RBC count; platelet concentrates for pH, yield and culture; fresh frozen plasma and cryoprecipitate were evaluated for unit volume, factor VIII and fibrinogen concentration. The mean HCT of packed red cells was 65.75+7.42%, volume was 238+26.25ml, Hb was 20.5+0.15g/dL and RBC count of 5.89x10+0.30x10. The mean platelet yield was 5.7x10, pH was ≥6.8+0.175 and volume was 82.5+13.75ml; cultures were negative and swirling was present in all the platelet units tested. Mean factor VIII and fibrinogen levels were found to be 95.25 +7.37and 307.5+41.37gm/l for FFP respectively. Mean volume, PT and APTT were 215+32.5ml, 14.15+0.325 sec and 29.50+1.5 sec respectively. The quality control of blood components ensures the timely availability of a blood component of high quality with maximum efficacy and minimal risk to potential recipients.


Sign in / Sign up

Export Citation Format

Share Document