Co-analysis of pancreatic cyst fluid carcinoembryonic antigen and glucose with novel cut-off levels better distinguishes between mucinous and non-mucinous neoplastic pancreatic cystic lesions

Author(s):  
Burcu Barutcuoglu ◽  
Nevin Oruc ◽  
Güneş Ak ◽  
Serdar Kucukokudan ◽  
Ahmet Aydın ◽  
...  

Background Pancreatic cyst fluid analysis plays an important role in distinguishing between mucinous and non-mucinous cyst lesions. We aimed to compare the diagnostic performances of cyst fluid carcinoembryonic antigen (CEA), CA 19-9, and glucose in differentiating mucinous from non-mucinous neoplastic pancreatic cystic lesions (PCLs) and determine the best cut-off levels. Methods Patients’ data were evaluated retrospectively. 102 patients’ PCLs were grouped as non-neoplastic ( n = 25), non-mucinous neoplastic ( n = 20), mucinous neoplastic ( n = 47) and pancreatic adenocarcinomas with cystic degeneration ( n = 10); and CEA, CA 19-9, and glucose levels were compared. Receiver-operating characteristic analysis was performed, and the ideal cut-off values were determined. Results Cyst fluid CEA and CA 19-9, levels were significantly higher ( P < 0.001, P < 0.001, respectively) and glucose levels were significantly lower ( P = 0.001) in mucinous than in non-mucinous neoplastic PCLs. Area under curve with 95% confidence interval of CEA, glucose and CEA and glucose test combination was 0.939 (95% CI = 0.885–0.993, P = 0.001), 0.809 (95% CI = 0.695–0.924, P < 0.001) and 0.937 (95% CI = 0.879–0.995), respectively. CEA cut-offs to rule-in and rule-out mucinous neoplastic were 135.1 ng/mL (sensitivity = 62%, specificity = 94.7%) and 6.12 ng/mL (sensitivity = 94.1%, specificity = 80.4%), respectively. Glucose cut-off of 2.8 mmol/L was chosen both to rule-in and rule-out mucinous neoplastic PCLs (sensitivity = 78%, specificity = 80%). Co-analysis of CEA and glucose to distinguish mucinous from non-mucinous neoplastic PCLs had sensitivity = 87.8%, specificity = 93.3%, and diagnostic accuracy = 89.3%. Conclusions We concluded that co-analysis of cyst fluid CEA (cut-off = 135.1 ng/mL) and glucose (cut-off = 2.8 mmol/L) at novel cut-offs had the best testing performance to rule-in mucinous neoplastic PCLs. To rule-out mucinous PCLs co-analysis of CEA (cut-off = 6.12 ng/mL) and glucose (cut-off = 2.8 mmol/L) added value to prediction.

2017 ◽  
Vol 85 (5) ◽  
pp. AB329-AB330
Author(s):  
Farhoud Khosravi ◽  
Mankanwal Sachdev ◽  
Ahmed Abdulameer ◽  
Ali Alshati ◽  
Sara Jackson ◽  
...  

The Analyst ◽  
2016 ◽  
Vol 141 (14) ◽  
pp. 4424-4431 ◽  
Author(s):  
Yingjie Yu ◽  
Qi Zhang ◽  
Jonathan Buscaglia ◽  
Chung-Chueh Chang ◽  
Ying Liu ◽  
...  

In this study, a real time potentiometric biosensor based on the 3D surface molecular imprinting was developed for CEA detection.


2016 ◽  
Vol 29 (1) ◽  
pp. 111-117 ◽  
Author(s):  
Abdurrahman Kadayifci ◽  
Mustafa Atar ◽  
Jessica L. Wang ◽  
David G. Forcione ◽  
Brenna W. Casey ◽  
...  

2009 ◽  
Vol 69 (6) ◽  
pp. 1106-1110 ◽  
Author(s):  
Mandeep S. Sawhney ◽  
Shiva Devarajan ◽  
Paul O'Farrel ◽  
Marcelo S. Cury ◽  
Rabi Kundu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document