REMATCH and Beyond: The Cost of Treating Heart Failure Using an Implantable Left Ventricular Assist Device

2006 ◽  
Vol 10 (3) ◽  
pp. 253-255 ◽  
Author(s):  
Walter P. Dembitsky
SLEEP ◽  
2021 ◽  
Vol 44 (Supplement_2) ◽  
pp. A324-A325
Author(s):  
Pratibha Anne ◽  
Rupa Koothirezhi ◽  
Ugorji Okorie ◽  
Minh Tam Ho ◽  
Brittany Monceaux ◽  
...  

Abstract Introduction Central sleep apnea is commonly seen in patients with heart failure. Here we present a case demonstrating shifting of predominant apneic events from central to obstructive type after placement of left ventricular assist device (LVAD) in end stage heart failure patient. Report of case(s) Case Presentation: 66 year-old African American male has past medical history of chronic congestive heart failure diabetes, hypertension, paroxysmal atrial fibrillation, anemia, hypothyroidism, chronic kidney disease and sleep apnea. Prior to his LVAD placement, his left ventricular ejection fraction (EF) was <10%. Patient was diagnosed with central sleep apnea with AHI of 58 (with 92% of apneic events being central events), oxygen nadir of 74%. Subsequently, patient had LVAD placed for symptomatic heart failure and repeat polysomnogram repeated at six month demonstrated an improved AHI of 45.8 with predominantly obstructive and mixed apneic events, with only 12.5% being central events. Conclusion This case report highlights not only the improvement of the sleep apnea in CHF treated with LVAD but also shows the shift of apneic events from predominantly central to obstructive type post LVAD. Support (if any) 1. Henein MY, Westaby S, Poole-Wilson PA, Cowie MR, Simonds AK. Resolution of central sleep apnoea following implantation of a left ventricular assist device. Int J Cardiol. 2010 Feb 4;138(3):317–9. PMID: 18752859. 2. Köhnlein T, Welte T, Tan LB, Elliott MW. Central sleep apnoea syndrome in patients with chronic heart disease: a critical review of the current literature. Thorax. 2002 Jun;57(6):547–54. PMID: 12037232 3. Monda C, Scala O, Paolillo S, Savarese G, Cecere M, D’Amore C, Parente A, Musella F, Mosca S, Filardi PP. Apnee notturne e scompenso cardiaco: fisiopatologia, diagnosi e terapia [Sleep apnea and heart failure: pathophysiology, diagnosis and therapy]. G Ital Cardiol (Rome). 2010 Nov;11(11):815–22. Italian. PMID: 21348318.


2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Selim Bozkurt ◽  
Koray K. Safak

Dilated cardiomyopathy is the most common type of the heart failure which can be characterized by impaired ventricular contractility. Mechanical circulatory support devices were introduced into practice for the heart failure patients to bridge the time between the decision to transplant and the actual transplantation which is not sufficient due to the state of donor organ supply. In this study, the hemodynamic response of a cardiovascular system that includes a dilated cardiomyopathic heart under support of a newly developed continuous flow left ventricular assist device—Heart Turcica Axial—was evaluated employing computer simulations. For the evaluation, a numerical model which describes the pressure-flow rate relations of Heart Turcica Axial, a cardiovascular system model describing the healthy and pathological hemodynamics, and a baroreflex model regulating the heart rate were used. Heart Turcica Axial was operated between 8000 rpm and 11000 rpm speeds with 1000 rpm increments for assessing the pump performance and response of the cardiovascular system. The results also give an insight about the range of the possible operating speeds of Heart Turcica Axial in a clinical application. Based on the findings, operating speed of Heart Turcica Axial should be between 10000 rpm and 11000 rpm.


Sign in / Sign up

Export Citation Format

Share Document