scholarly journals Novel Technique for the Treatment of Type Ia Endoleak After Endovascular Abdominal Aortic Aneurysm Repair

2021 ◽  
pp. 152660282110104
Author(s):  
Piotr M. Kasprzak ◽  
Karin Pfister ◽  
Waclaw Kuczmik ◽  
Wilma Schierling ◽  
Georgios Sachsamanis ◽  
...  

Purpose Open surgical repair of type Ia endoleak after endovascular aortic aneurysm repair/sealing (EVAR/EVAS) is associated with significant perioperative mortality and morbidity. Current endovascular redo techniques face limitations, especially when the infrarenal landing zone is inadequate and the previous endograft is rigid and features a short or no main body. We present a novel concept for the treatment of type Ia endoleak using a custom-made branched device. Technique The 5-branch-device (Cook Medical, Bloomington, IN, USA) consists of a nitinol skeleton with branches, covered with a low-profile polyester fabric loaded in an 18F sheath. The device features a minimum of 2 proximal sealing stents and includes branches for renovisceral vessels as well as an additional 8 mm branch for the contralateral iliac limb. Implantation and sealing in the renovisceral vessels is carried out in standard fashion, using transfemoral and transaxillary access. Distal sealing is achieved by tapering the branched component into the ipsilateral iliac limb and using a bridging balloon-expandable or self-expandable stent-graft through the additional branch to the preexisting contralateral iliac limb. Conclusion Treatment of type Ia endoleak with a new custom-made device enables sufficient proximal seal while minimizing suprarenal aortic coverage and facilitates adequate component overlap. The low profile branched design accommodates implantation through the preexisting endograft and catheterization of target vessels.

Vascular ◽  
2007 ◽  
Vol 15 (3) ◽  
pp. 167-171 ◽  
Author(s):  
Chris Klonaris ◽  
Sotiris Georgopoulos ◽  
Fotis Markatis ◽  
Athanasios Katsargyris ◽  
Chris Tsigris ◽  
...  

We report the successful endovascular repair of a ruptured abdominal aortic aneurysm (AAA) in a multimorbid patient 8 months after endovascular abdominal aortic aneurysm repair (EVAR). A 74-year-old man with a history of EVAR 8 months earlier presented with hypotension, severe back pain, and tenderness on abdominal palpation. A contrast-enhanced computed tomographic scan showed a large retroperitoneal hematoma and confirmed the diagnosis of secondary abdominal aortic rupture. Because the patient had severe comorbidities, the endovascular method was chosen for further management. Two stent grafts were placed appropriately to eliminate a type 1a and a type 3 endoleak owing to modular separation of the left iliac graft limb from the main body stent graft. An additional self-expanding stent was deployed in the solitary right renal artery to open its origin, which was partially overlapped by the proximal cuff. The patient was discharged on the tenth postoperative day and is alive and well 1 year postoperatively. This case indicates that endovascular repair is feasible not only in cases of primarily ruptured AAAs but also in secondarily ruptured AAAs after failure of EVAR.


2015 ◽  
Vol 61 (1) ◽  
pp. 275-279 ◽  
Author(s):  
Adam Q. Howard ◽  
Sidhartha Sinha ◽  
Anthony Edwards ◽  
Ijaz Ahmad ◽  
Christopher M. Backhouse ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document