Duplex Ultrasound Surveillance After Uncomplicated Endovascular Abdominal Aortic Aneurysm Repair

2017 ◽  
Vol 51 (5) ◽  
pp. 295-300 ◽  
Author(s):  
Jacob S. Schaeffer ◽  
Irina Shakhnovich ◽  
Kyle N. Sieck ◽  
Kara J. Kallies ◽  
Clark A. Davis ◽  
...  

Objectives: Health-care costs and risks of radiation and intravenous contrast exposure challenge computed tomography angiography (CTA) as the standard surveillance method after endovascular abdominal aortic aneurysm repair (EVAR). We reviewed our experience using Duplex ultrasound scan (DUS) as an initial and subsequent surveillance technique after uncomplicated EVAR. Methods: The medical records of patients who underwent EVAR from 2004 to 2014 with at least 1 postoperative imaging study were retrospectively reviewed. Duplex ultrasound scan was the primary modality, with CTA reserved for patients with suspicious findings. Results: Mean follow-up was 3.2 years for 266 patients. Fifty-seven endoleaks (7 type I, 50 type II) were detected in 51 patients (19%). Nineteen (33%) endoleaks were identified and monitored by DUS alone. Nine (16%) endoleaks were identified on CTA without prior DUS. Twenty-two (39%) endoleaks were identified on DUS and confirmed by CTA; 6 of these patients had a secondary intervention. When compared to subsequent CTA, there were 7 discordant results: 4 false-negative and 3 false-positive endoleaks on DUS. Two of these patients with discordant results required intervention. Follow-up CTA was not obtained for the other 2 patients due to severe comorbidities including renal disease. One of these patients eventually developed abdominal aortic aneurysm rupture and death. Among 88 patients with both DUS and CTA, positive predictive value and negative predictive value for DUS were 0.88 and 0.94, respectively. Sac size on DUS compared to CTA resulted in an interclass correlation coefficient of r = .84. Conclusions: In our experience, DUS was safe and effective for initial and follow-up surveillance after uncomplicated EVAR.

2016 ◽  
Vol 49 (4) ◽  
pp. 229-233 ◽  
Author(s):  
Alex Aparecido Cantador ◽  
Daniel Emílio Dalledone Siqueira ◽  
Octavio Barcellos Jacobsen ◽  
Jamal Baracat ◽  
Ines Minniti Rodrigues Pereira ◽  
...  

Abstract Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation.


Vascular ◽  
2016 ◽  
Vol 25 (3) ◽  
pp. 234-241 ◽  
Author(s):  
Guus W van Lammeren ◽  
Çağdaş Ünlü ◽  
Sjoerd Verschoor ◽  
Eric P van Dongen ◽  
Jan Wille ◽  
...  

Objectives Endovascular treatment of pararenal abdominal aortic aneurysm has gained terrain over the past decade, despite the substantial need for reinterventions during follow-up. However, open repair is still a well-established treatment option. With the current study we report the results of a consecutive series of elective primary open pararenal abdominal aortic aneurysm repair in a tertiary vascular referral centre, combined with an overview of current literature and pooled data analysis of perioperative mortality of open and endovascular pararenal abdominal aortic aneurysm repair. Methods A retrospective analysis of a prospective database of all elective open pararenal abdominal aortic aneurysm repairs in the St. Antonius Hospital between 2005 and 2014 was performed. Primary endpoint was 30-day mortality. Secondary endpoints were 30-day morbidity, new onset dialysis, reintervention free survival, and overall survival during follow-up. Results Between 2005 and 2014, 214 consecutive patients underwent elective open pararenal abdominal aortic aneurysm repair. Mean age was 69.8 (±7.1) years, 82.7% (177/214) were men, and mean abdominal aortic aneurysm diameter was 62 (±11) mm. Thirty-day mortality was 3.4%. Thirty-day morbidity was 27.1%, which predominantly consisted of pneumonia (18.7% (40/214)), cardiac events (3.3% (7/214)), and new onset dialysis (2.8% (6/214)). Estimated five-year overall survival rate was 74.2%. 0.9% (2/214) of patients required abdominal aortic aneurysm-related reintervention, and an additional 2.3% (5/214) required surgical repair of an incisional hernia. Pooled analysis of literature revealed a 30-day mortality of 3.0% for open pararenal repair and 1.9% for fenestrated endovascular repair. Conclusion Open pararenal abdominal aortic aneurysm repair in the era of increasing endovascular options results in acceptable perioperative morbidity and mortality rates. Mid-term reintervention rate is low compared to fenestrated endovascular aneurysm repair. Expertise with open repair still remains essential for treatment of pararenal abdominal aortic aneurysms in the near future, especially for those patients that are declined for endovascular treatment.


Radiology ◽  
2009 ◽  
Vol 253 (1) ◽  
pp. 253-262 ◽  
Author(s):  
Thorsten A. Bley ◽  
Peter J. Chase ◽  
Scott B. Reeder ◽  
Christopher J. François ◽  
Kazuhiko Shinki ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document