Computational Fluid Dynamics to Assess Hemodynamic Forces in Abdominal Aortic Aneurysm

2021 ◽  
pp. 153857442110686
Author(s):  
Maurizio Domanin ◽  
Christian Vergara ◽  
Daniele Bissacco ◽  
Santi Trimarchi
2021 ◽  
pp. 153857442110129
Author(s):  
Mauricio Gonzalez-Urquijo ◽  
Raul Garza de Zamacona ◽  
Ana Karen Martinez Mendoza ◽  
Miranda Zamora Iribarren ◽  
Erika Garza Ibarra ◽  
...  

Background: Besides biological factors, abdominal aortic aneurysm rupture is also caused by mechanical parameters, which are constantly affecting the wall’s tissue due to their abnormal values. The ability to evaluate these parameters could vastly improve the clinical treatment of patients with abdominal aortic aneurysms. The objective of this study was to develop and demonstrate a methodology to analyze the fluid dynamics that cause the wall stress distribution in abdominal aortic aneurysms, using accurate 3D geometry and a realistic, nonlinear, elastic biomechanical model using a computer-aided software. Methods: The geometry of the abdominal aortic aneurysm; was constructed on a 3D scale using computer-aided software SolidWorks (Dassault Systems SolidWorksCorp., Waltham MA). Due to the complex nature of the abdominal aortic aneurysm geometry, the physiological forces and constraints acting on the abdominal aortic aneurysm wall were measured by using a simulation setup using boundary conditions and initial conditions for different studies such as finite element analysis or computational fluid dynamics. Results: The flow pattern showed an increase velocity at the angular neck, followed by a stagnated flow inside the aneurysm sack. Furthermore, the wall shear stress analysis showed to focalized points of higher stress, the top and bottom of the aneurysm sack, where the flow collides against the wall. An increase of the viscosity showed no significant velocity changed but results in a slight increase in overall pressure and wall shear stress. Conclusions: Conducting computational fluid dynamics modeling of the abdominal aortic aneurysm using computer-aided software SolidWorks (Dassault Systems SolidWorksCorp., Waltham MA) proves to be an insightful approach for the clinical setting. The careful consideration of the biomechanics of the abdominal aortic aneurysm may lead to an improved, case-specific prediction of the abdominal aortic aneurysm rupture potential, which could significantly improve the clinical management of these patients.


2014 ◽  
Vol 136 (3) ◽  
Author(s):  
Chia-Yuan Chen ◽  
Raúl Antón ◽  
Ming-yang Hung ◽  
Prahlad Menon ◽  
Ender A. Finol ◽  
...  

The pathology of the human abdominal aortic aneurysm (AAA) and its relationship to the later complication of intraluminal thrombus (ILT) formation remains unclear. The hemodynamics in the diseased abdominal aorta are hypothesized to be a key contributor to the formation and growth of ILT. The objective of this investigation is to establish a reliable 3D flow visualization method with corresponding validation tests with high confidence in order to provide insight into the basic hemodynamic features for a better understanding of hemodynamics in AAA pathology and seek potential treatment for AAA diseases. A stereoscopic particle image velocity (PIV) experiment was conducted using transparent patient-specific experimental AAA models (with and without ILT) at three axial planes. Results show that before ILT formation, a 3D vortex was generated in the AAA phantom. This geometry-related vortex was not observed after the formation of ILT, indicating its possible role in the subsequent appearance of ILT in this patient. It may indicate that a longer residence time of recirculated blood flow in the aortic lumen due to this vortex caused sufficient shear-induced platelet activation to develop ILT and maintain uniform flow conditions. Additionally, two computational fluid dynamics (CFD) modeling codes (Fluent and an in-house cardiovascular CFD code) were compared with the two-dimensional, three-component velocity stereoscopic PIV data. Results showed that correlation coefficients of the out-of-plane velocity data between PIV and both CFD methods are greater than 0.85, demonstrating good quantitative agreement. The stereoscopic PIV study can be utilized as test case templates for ongoing efforts in cardiovascular CFD solver development. Likewise, it is envisaged that the patient-specific data may provide a benchmark for further studying hemodynamics of actual AAA, ILT, and their convolution effects under physiological conditions for clinical applications.


2014 ◽  
Vol 63 (12) ◽  
pp. A1213
Author(s):  
Thao Phuong Nghiem ◽  
Ramiro Moreno ◽  
Minh Hoang Tran ◽  
Anne Negre Salvayre ◽  
Hervé Rousseau

Sign in / Sign up

Export Citation Format

Share Document