Secondary Relining With Focal Flaring of Novel-Generation Balloon-Expandable Covered Stents for Endovascular Treatment of Significant Diameter Mismatch in the Aorto-Iliac Territory

Vascular ◽  
2020 ◽  
pp. 170853812094505
Author(s):  
Mario D’Oria ◽  
Filippo Griselli ◽  
Davide Mastrorilli ◽  
Filippo Gorgatti ◽  
Silvia Bassini ◽  
...  

Objectives The aim of this study was to report on the safety and feasibility of secondary relining with focal flaring of novel-generation balloon-expandable covered stents for endovascular treatment of significant diameter mismatch in the aorto-iliac territory. Significant diameter mismatch was defined as >20% difference in the nominal diameter between the intended proximal and distal landing zones. Methods Patient A was an 84-year-old man with prior abdominal aortic aneurysm open repair with a straight 20 mm Dacron tube. He presented with a right common iliac artery aneurysm (Ø88 mm) with contained rupture. The Gore Viabahn endoprosthesis (9 mm × 5 cm) was inserted proximally about 15 mm above the occluded ostium of the internal iliac artery. Subsequently, the BeGraft Aortic® (16 mm × 48 mm) was inserted proximally up to the common iliac artery origin; its proximal portion was flared to 22 mm. Patient B was a 77-year-old man with prior endovascular abdominal aortic aneurysm repair with a Medtronic Endurant stent-graft. He presented with occlusion of the right limb of the aortic endoprosthesis and thrombosis that extended down to the level of the superficial femoral artery. After mechanical thrombectomy, two Gore Viabahn endoprosthesis (first one, 8 mm × 10 cm; second one, 10 mm × 15 cm) were inserted into the right iliac limb. Subsequently, the BeGraft Aortic® (12mm × 39mm) was inserted proximally up to the gate of the aortic stent-graft; its proximal portion was flared to 16 mm. Results Technical success and clinical success were achieved in both patients. Imaging follow-up (6 months for Patient A, 12 months for Patient B) showed correct placement of all stent-grafts without any graft-related adverse event. The patients remained free from new reinterventions or recurrent symptoms. Patient A died 8 months after the index procedure from acute respiratory failure after community acquired pneumonia. Conclusion Secondary relining with focal flaring of novel-generation balloon-expandable covered stents for endovascular treatment of significant diameter mismatch in the aorto-iliac territory is safe and feasible. Although mid-term results seem to be effective, longer follow-up is warranted to establish durability of the technique.

Vascular ◽  
2016 ◽  
Vol 25 (2) ◽  
pp. 190-195 ◽  
Author(s):  
Steven MM van Sterkenburg ◽  
Leo H van den Ham ◽  
Luuk Smeets ◽  
Jan-Willem Lardenoije ◽  
Michel MPJ Reijnen

Introduction Concomitant abdominal aortic aneurysm formation and aortoiliac occlusive disease is a challenging combination, often requiring open reconstructive surgery. In this study, we have assessed a single center experience of the Nellix EndoVascular Aneurysm Sealing System in the treatment of an abdominal aortic aneurysm in conjunction with iliac artery occlusive disease. Methods Retrospectively case files of patients treated with Nellix EndoVascular Aneurysm Sealing System in a single center were reviewed. The primary endpoints of the study were the technical success of Nellix EndoVascular Aneurysm Sealing System in patients with coincidental iliac artery occlusive disease and the successful exclusion of the aneurysm during follow-up. Results Of the 96 patients that were treated with Nellix EndoVascular Aneurysm Sealing System, five were identified that had an abdominal aortic aneurysm in conjunction with iliac artery occlusive disease. Treated patients had either unilateral (n = 4) or bilateral (n = 1) common iliac artery occlusive disease varying from 70% stenosis to complete occlusions. The lesion length varied from 5 to 50 mm and in two cases it involved an occluded bare metal stent. The indication for surgery was the abdominal aortic aneurysm in all patients, including three also suffering from claudication. In all patients the iliac artery occlusive disease was pretreated with balloon-expandable covered stents. Technical success was achieved in all five patients. After a median follow-up of nine months all stents were patent with no signs of endoleak and stable aneurysm diameters. All patients were free of intermittent claudication or ischemic wounds. Conclusion Nellix EndoVascular Aneurysm Sealing System seems feasible and safe in patients with a combination of abdominal aortic aneurysm and iliac artery occlusive disease.


Vascular ◽  
2020 ◽  
pp. 170853812097591
Author(s):  
Mian Wang ◽  
Luis M Bartolozzi ◽  
Vincent Riambau

Introduction To report total endovascular treatment for a rare case of Crawford extent IV thoraco-abdominal aortic aneurysm (TAAA) using custom-designed branched device in a patient with Behçet’s disease. Methods A 50 years’ old man with history of BD was accidentally diagnosed Crawford extent IV TAAA during computed tomography follow-up after left nephrectomy of renal carcinoma. The aneurysm extended from descending aorta to right common iliac artery with a maximum diameter of 6.2 cm. Results The endovascular procedure wassuccessfully performed using custom-designed branched component to cannulate visceral arteries, bifurcated endograft and iliac legs to exclude the aneurysm sac in abdominal aorta and an iliac branched device to preserve the right internal iliac artery. The patient was discharged without any complication. Computed tomography angiogram at one month after endovascular repair demonstrated total exclusion of the aneurysm, patent visceral branches and right internal iliac artery. No complication occurred to six-month follow-up. Conclusion Endovascular treatment of stable TAAA in patients with Behc?et's disease using custom-designed branched device is feasible, microinvasive and safe. The long-term efficacy needs to be observed.


2017 ◽  
Vol 52 (2) ◽  
pp. 135-137 ◽  
Author(s):  
Geert Maleux ◽  
Sabrina Houthoofd ◽  
Lien Poorteman ◽  
Inge Fourneau

We report on a 54-year-old man who presented with an atypical, proximal, intraoperative endoleak after endovascular aortic repair with an Ovation endograft for a 65-mm-diameter abdominal aortic aneurysm. The endografting was complicated by inadvertent bilateral iliac limb insertion into the right gate without cannulation of the left gate. The endoleak was treated by brachial approach: Through the open left gate, the outflow inferior mesenteric artery was coil embolized and the inflow left gate was closed with an Amplatzer plug. Follow-up computed tomography over 3 years showed absence of any endoleak and a stable diameter of the excluded abdominal aortic aneurysm.


VASA ◽  
2009 ◽  
Vol 38 (1) ◽  
pp. 91-93 ◽  
Author(s):  
Borioni ◽  
De Luca ◽  
Maspes ◽  
Sciuto ◽  
Garofalo

The purpose of this report is to describe the endovascular exclusion of an internal iliac artery (IIA) aneurysm in emergency setting, long after abdominal aortic aneurysm surgical repair. An 85-year-old male presented with a contained rupture of a huge IIA aneurysm, ten years after aortoiliac bifurcated grafting. Because of poor clinical conditions an emergency endovascular treatment was planned. A stent-graft was positioned from the proximal right branch of the bifurcated surgical prosthesis to the distal external iliac artery, covering the hypogastric aneurysm neck. One month after the procedure, CT scan demonstrated the complete exclusion of the aneurysm. Endovascular treatment of IIA aneurysms is an excellent option to reduce perioperative morbidity and mortality in high risk patients, particularly in an emergency setting.


2009 ◽  
Vol 137 (1-2) ◽  
pp. 10-17 ◽  
Author(s):  
Lazar Davidovic ◽  
Momcilo Colic ◽  
Igor Koncar ◽  
Dejan Markovic ◽  
Dusan Kostic ◽  
...  

Introduction. Endovascular aneurysm repair (EVAR) has been introduced into clinical practice at the beginning of the 90's of the last century. Because of economic, political and social problems during the last 25 years, the introduction of this procedure in Serbia was not possible. Objective. The aim of this study was to present preliminary experiences and results of the Clinic for Vascular Surgery of the Serbian Clinical Centre in Belgrade in endovascular treatment of thoracic and abdominal aortic aneurysms. Methods. The procedure was performed in 33 patients (3 female and 30 male), aged from 42 to 83 years. Ten patients had a descending thoracic aorta aneurysm (three atherosclerotic, four traumatic - three chronic and one acute as a part of polytrauma, one dissected, two penetrated atherosclerotic ulcers), while 23 patients had the abdominal aortic aneurysm, one ruptured and two isolated iliac artery aneurysms. The indications for EVAR were isthmic aneurismal localisation, aged over 80 years and associated comorbidity (cardiac, pulmonary and cerebrovasular diseases, previous thoracotomy or multiple laparotomies associated with abdominal infection, idiopatic thrombocitopaenia). All of these patients had three or more risk factors. The diagnosis was established using duplex ultrasonography, angiography and MSCT. In the case of thoracic aneurysm, a Medtronic-Valiant? endovascular stent graft was implanted, while for the abdominal aortic aneurysm Medtronic-Talent? endovascular stent grafts with delivery systems were used. In three patients, following EVAR a surgical repair of the femoral artery aneurysm was performed, and in another three patients femoro-femoral cross over bypass followed implantation of aortouniiliac stent graft. Results. During procedure and follow-up period (mean 1.6 years), there were: one death, one conversion, one endoleak type 1, six patients with endoleak type 2 that disappeared during the follow-up period, one early graft thrombosis. No other complications, including aneurysm expansion, collapse, deformity and migration of the endovascular stent grafts, were registered. Conclusion. According to all medical and economic aspects, we recommend EVAR to treat acute traumatic thoracic aortic aneurysm, as well as in elderly and high-risk patients with abdominal or thoracic aneurysms, when open surgery is related to a significantly higher mortality and morbidity.


Ensho ◽  
2000 ◽  
Vol 20 (5) ◽  
pp. 619-623
Author(s):  
Hiroaki Inamura ◽  
Motohiro Kurosawa ◽  
Jun-ichiro Morioka ◽  
Rieko Nakagami ◽  
Yutaka Mizushima ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document