stent grafts
Recently Published Documents


TOTAL DOCUMENTS

1312
(FIVE YEARS 244)

H-INDEX

63
(FIVE YEARS 5)

2022 ◽  
Vol 8 ◽  
Author(s):  
Yifei Pei ◽  
Hongqiao Zhu ◽  
Yu Xiao ◽  
Jian Zhou ◽  
Zaiping Jing

Objective: To examine the feasibility, integrity, efficacy, and safety of endovascular repair of the aortic arch pathologies with the mini-cross prefenestration (MCPF) on stent grafts.Methods: First, to prove the feasibility of the MCPF, an in-vitro prefenestration experiment was conducted. Second, to examine the integrity of the MCPF stent grafts, a fatigue test was conducted. Then, the membranes and metal structures of stent grafts were examined by light microscopy and scanning electron microscopy (SEM). Third, a clinical experiment was conducted to investigate the efficacy and safety of this novel technique (ClinicalTrials.gov Identifier: NCT04544579).Results: All the 12 branch stents were successfully implanted and flared in vitro. After the fatigue test stimulating a 5-year cardiac cycle, no obvious disintegration or fracture was found in light microscopy or SEM. From December 2017 to February 2020, 26 patients with left subclavian arteries and/or left common carotid arteries involved received the novel technique. The endovascular repair with the MCPF was successfully performed on all the 26 (100%) patients. Eighteen (69.2%) patients underwent the reconstruction of the left subclavian artery (LSCA) only. The fenestrations of both the LSCA and left common carotid artery (LCCA) were conducted in 8 (30.8%) patients. Median operative time was 120 [interquartile range (IQR), 95–137.5] min and median revascularization time of the LSCA and LCCA was 30.5 (IQR, 22.8–42.0) s and 20.0 (IQR, 18.0–32.0) s separately. During the median follow-up duration of 38.9 (range, 18.8–44.2) months, one case needed an open surgery because of retrograde type A aortic dissection 3 months after implantation and no other complications or mortality occurred. The maximum aortic diameters were significantly decreased in patients with thoracic aortic dissection and thoracic aortic aneurysm (p < 0.05).Conclusion: The existing evidence demonstrated the safety, rapid branch artery revascularization, and positive aortic remodeling of the novel technique. Long-term observation is warranted to prove the durability.


2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Min-Tsun Liao ◽  
Chien-Ming Luo ◽  
Ming-Chien Hsieh ◽  
Mu-Yang Hsieh ◽  
Chih-Ching Lin ◽  
...  

AbstractThis study aimed to compare stent graft with balloon tamponade for ruptured dialysis access during percutaneous transluminal angioplasty. Patients over an 8-year period (2010–2018) were identified from a database of 11,609 procedures. The primary endpoint was target lesion primary patency at 12 months. A total of 143 patients who had rupture dialysis access were enrolled, of whom 52 were salvaged by stent grafts and 91 were salvaged by balloon tamponade. The 6-month target lesion primary patency was greater in the stent graft group than in the balloon tamponade group (66.7% vs. 29.5%, P < 0.001). The benefit of stent grafts was sustained for 12 months (52.5% vs. 9.0%, P < 0.001). The stent grafts increased the median time from the index procedure to the next intervention in the ruptured area by 171 days (260 vs. 89 days) at 12 months. There was no significant difference in the access circuit patency rates at 6 months (25.5% vs. 19.8%, P = 0.203) and 12 months (12.0% vs. 5.8%, P = 0.052). The patency results of the stent grafts remained after the multivariable adjustment analysis. Compared to balloon tamponade alone, stent grafts provided superior target lesion primary patency at 6 and 12 months. The access circuit patency rates were similar.


Author(s):  
Bidan Huang ◽  
Ya-Yen Tsai ◽  
Guang-Zhong Yang

2022 ◽  
pp. 114-125
Author(s):  
David Schechtman ◽  
Brandon W. Propper
Keyword(s):  

2022 ◽  
Vol 75 (1) ◽  
pp. e32
Author(s):  
Kyongjune B. Lee ◽  
Jesus Porras Colon ◽  
Carla K. Scott ◽  
Felipe L. Pavarino ◽  
Mirza S. Baig ◽  
...  

2021 ◽  
Vol 12 ◽  
Author(s):  
Ming Qing ◽  
Yue Qiu ◽  
Jiarong Wang ◽  
Tinghui Zheng ◽  
Ding Yuan

Objectives: Cross-limb stent grafts for endovascular aneurysm repair (EVAR) are often employed for abdominal aortic aneurysms (AAAs) with significant aortic neck angulation. Neck angulation may be coronal or sagittal; however, previous hemodynamic studies of cross-limb EVAR stent grafts (SGs) primarily utilized simplified planar neck geometries. This study examined the differences in flow patterns and hemodynamic parameters between crossed and non-crossed limb SGs at different spatial neck angulations.Methods: Ideal models consisting of 13 cross and 13 non-cross limbs were established, with coronal and sagittal angles ranging from 0 to 90°. Computational fluid dynamics (CFD) was used to capture the hemodynamic information, and the differences were compared.Results: With regards to the pressure drop index, the maximum difference caused by the configuration and angular direction was 4.6 and 8.0%, respectively, but the difference resulting from the change in aneurysm neck angle can reach 27.1%. With regards to the SAR-TAWSS index, the maximum difference caused by the configuration and angular direction was 7.8 and 9.8%, respectively, but the difference resulting from the change in aneurysm neck angle can reach 26.7%. In addition, when the aneurysm neck angle is lower than 45°, the configuration and angular direction significantly influence the OSI and helical flow intensity index. However, when the aneurysm neck angle is greater than 45°, the hemodynamic differences of each model at the same aneurysm neck angle are reduced.Conclusion: The main factor affecting the hemodynamic index was the angle of the aneurysm neck, while the configuration and angular direction had little effect on the hemodynamics. Furthermore, when the aneurysm neck was greatly angulated, the cross-limb technique did not increase the risk of thrombosis.


Sign in / Sign up

Export Citation Format

Share Document