Minimal incision bone graft and screw fixation for scaphoid nonunion with substantial bone loss

2021 ◽  
pp. 175319342110005
Author(s):  
Edward Kahhaleh ◽  
Antonia Gkotsi ◽  
Wissam El Kazzi
2011 ◽  
Vol 16 (6) ◽  
pp. 749-755 ◽  
Author(s):  
Hiroyuki Matsuki ◽  
Shigeharu Uchiyama ◽  
Hiroyuki Kato ◽  
Junichi Ishikawa ◽  
Norimasa Iwasaki ◽  
...  

2013 ◽  
Vol 30 (3) ◽  
pp. 261-263
Author(s):  
Alper Çıraklı ◽  
Ahmet Pişkin ◽  
Sevgi Çıraklı ◽  
Ali Varlı ◽  
Birol Gülman

Hand ◽  
2021 ◽  
pp. 155894472097411
Author(s):  
Luke T. Nicholson ◽  
Kristen M. Sochol ◽  
Ali Azad ◽  
Ram Kiran Alluri ◽  
J. Ryan Hill ◽  
...  

Background: Management of scaphoid nonunions with bone loss varies substantially. Commonly, internal fixation consists of a single headless compression screw. Recently, some authors have reported on the theoretical benefits of dual-screw fixation. We hypothesized that using 2 headless compression screws would impart improved stiffness over a single-screw construct. Methods: Using a cadaveric model, we compared biomechanical characteristics of a single tapered 3.5- to 3.6-mm headless compression screw with 2 tapered 2.5- to 2.8-mm headless compression screws in a scaphoid waist nonunion model. The primary outcome measurement was construct stiffness. Secondary outcome measurements included load at 1 and 2 mm of displacement, load to failure for each specimen, and qualitative assessment of mode of failure. Results: Stiffness during load to failure was not significantly different between single- and double-screw configurations ( P = .8). Load to failure demonstrated no statistically significant difference between single- and double-screw configurations. Using a qualitative assessment, the double-screw construct maintained rotational stability more than the single-screw construct ( P = .029). Conclusions: Single- and double-screw fixation constructs in a cadaveric scaphoid nonunion model demonstrate similar construct stiffness, load to failure, and load to 1- and 2-mm displacement. Modes of failure may differ between constructs and represent an area for further study. The theoretical benefit of dual-screw fixation should be weighed against the morphologic limitations to placing 2 screws in a scaphoid nonunion.


Injury ◽  
2015 ◽  
Vol 46 ◽  
pp. S47-S52 ◽  
Author(s):  
Taçkın Özalp ◽  
Çağlar Öz ◽  
Gürler Kale ◽  
Serkan Erkan

2021 ◽  
pp. 175319342110308
Author(s):  
Toshiyasu Nakamura ◽  
Pak Cheong Ho ◽  
Andrea Atzei ◽  
Fernando Corella ◽  
Jan-Ragnar Haugstvedt

Recent technical and technological developments in wrist arthroscopic surgery allow for advanced treatments of difficult wrist disorders. In this review, world leaders of wrist arthroscopy describe bone graft for scaphoid nonunion, transosseous repair for triangular fibrocartilage fovea avulsion, palmaris longus reconstruction of the triangular fibrocartilage, and arthroscopic reconstruction of the scapholunate and lunotriquetral ligaments.


Sign in / Sign up

Export Citation Format

Share Document