Revolutions in arthroscopic wrist surgeries

2021 ◽  
pp. 175319342110308
Author(s):  
Toshiyasu Nakamura ◽  
Pak Cheong Ho ◽  
Andrea Atzei ◽  
Fernando Corella ◽  
Jan-Ragnar Haugstvedt

Recent technical and technological developments in wrist arthroscopic surgery allow for advanced treatments of difficult wrist disorders. In this review, world leaders of wrist arthroscopy describe bone graft for scaphoid nonunion, transosseous repair for triangular fibrocartilage fovea avulsion, palmaris longus reconstruction of the triangular fibrocartilage, and arthroscopic reconstruction of the scapholunate and lunotriquetral ligaments.

Author(s):  
Francisco J. Lucas ◽  
Vicente Carratalá ◽  
Ignacio Miranda ◽  
Cristobal Martinez-Andrade

Abstract Background Advances in wrist arthroscopy and the emergence of novel surgical techniques have created a need for new portals to the wrist. The aim of this study was to define and verify the safety of the volar distal radioulnar (VDRU) portal. Description of the Technique The VDRU portal is located ∼5 to 10 mm proximal to the proximal wrist crease, just on the ulnar edge of flexor carpi ulnaris tendon and radial to the dorsal cutaneous branch of the ulnar nerve. The ulnar styloid marks the distal point of the portal. Methods An anatomical study was performed on 12 upper extremity specimens of 6 human cadavers. Iatrogenic injuries of neurovascular structures potentially at risk were assessed, and the distance from the portal to these structures was measured. Results No iatrogenic injuries of the structures at risk occurred. Mean distances from the VDRU portal to the ulnar neurovascular bundle, the radial branch of the dorsal sensory branches of the ulnar nerve (DSBUN), and the ulnar branch of the DSBUN were 9.29 ± 0.26 mm, 8.08 ± 0.25 mm, and 10.58 ± 0.23 mm, respectively. There were no differences between left and right wrists. The distances from the VDRU portal to the ulnar neurovascular bundle and the ulnar branch of the DSBUN were significantly shorter in women; this distance was not less than 7 mm in any case. Conclusions The VDRU portal is safe, reproducible, and facilitates the implementation of various techniques related to triangular fibrocartilage complex pathology.


Injury ◽  
2015 ◽  
Vol 46 ◽  
pp. S47-S52 ◽  
Author(s):  
Taçkın Özalp ◽  
Çağlar Öz ◽  
Gürler Kale ◽  
Serkan Erkan

2016 ◽  
Vol 41 (5) ◽  
pp. 516-520 ◽  
Author(s):  
K. Kasapinova ◽  
V. Kamiloski

Our purpose was to determine the correlation of initial radiographic parameters of a distal radius fracture with an injury of the triangular fibrocartilage complex. In a prospective study, 85 patients with surgically treated distal radius fractures were included. Wrist arthroscopy was used to identify and classify triangular fibrocartilage complex lesions. The initial radial length and angulation, dorsal angulation, ulnar variance and distal radioulnar distance were measured. Wrist arthroscopy identified a triangular fibrocartilage complex lesion in 45 patients. Statistical analysis did not identify a correlation with any single radiographic parameter of the distal radius fractures with the associated triangular fibrocartilage complex injuries. The initial radiograph of a distal radius fracture does not predict a triangular fibrocartilage complex injury. Level of evidence: III


2018 ◽  
Vol 07 (05) ◽  
pp. 375-381 ◽  
Author(s):  
Peter Tang ◽  
Keiji Fujio ◽  
Robert Strauch ◽  
Melvin Rosenwasser ◽  
Taiichi Matsumoto

Background Transosseous repair of foveal detachment of the triangular fibrocartilage complex (TFCC) is effective for distal radioulnar joint stabilization. However, studies of the optimal foveal and TFCC suture positions are scant. Purpose The purpose of this study was to clarify the optimal TFCC suture position and bone tunnels for transosseous foveal repair. Materials and Methods Seven cadavers were utilized. The TFCC was incised at the foveal insertion and sutured at six locations (TFCCs 1–6) using inelastic sutures. Six osseous tunnels were created in the fovea (foveae 1–6). Fovea 2 is located at the center of the circle formed by the ulnar head overlooking the distal end of the ulna (theoretical center of rotation); fovea 5 is located 2 mm ulnar to fovea 2. TFCC 5 is at the ulnar apex of the TFCC disc; TFCC 4 is 2 mm dorsal to TFCC 5. TFCC 1 to 6 sutures were then placed through each of the six osseous tunnels, resulting in 36 combinations, which were individually tested. The forearm was placed in five positions between supination and pronation, and the degree of suture displacement was measured. The position with the least displacement indicated the isometric point of the TFCC and fovea. Results The mean distance of suture displacement was 2.4 ± 1.6 mm. Fovea 2, combined with any TFCC location, (0.7 ± 0.6 mm) and fovea group 5, combined with TFCC 4 location (0.8 ± 0.8) or with TFCC 5 location (0.9 ± 0.6) had statistically shorter suture displacements than any other fovea groups. Conclusion For TFCC transosseous repair, osseous tunnel position was more important than TFCC suture location.


2016 ◽  
Vol 24 (3) ◽  
pp. 159-163
Author(s):  
ANTONIO TUFI NEDER FILHO ◽  
EDUARDO TRALDI FRANCESCHINI ◽  
ARLINDO GOMES PARDINI JÚNIOR ◽  
MARCELO RIBERTO ◽  
NILTON MAZZER

2016 ◽  
Vol 41 (7) ◽  
pp. 732-738 ◽  
Author(s):  
J. K. Andersson ◽  
P. Axelsson ◽  
J. Strömberg ◽  
J. Karlsson ◽  
J. Fridén

A total of 20 patients scheduled for wrist arthroscopy, all with clinical signs of rupture to the triangular fibrocartilage complex and distal radioulnar joint instability, were tested pre-operatively by an independent observer for strength of forearm rotation. During surgery, the intra-articular pathology was documented by photography and also subsequently individually analysed by another independent hand surgeon. Arthroscopy revealed a type 1-B injury to the triangular fibrocartilage complex in 18 of 20 patients. Inter-rater reliability between the operating surgeon and the independent reviewer showed absolute agreement in all but one patient (95%) in terms of the injury to the triangular fibrocartilage complex and its classification. The average pre-operative torque strength was 71% of the strength of the non-injured contralateral side in pronation and supination. Distal radioulnar joint instability with an arthroscopically verified injury to the triangular fibrocartilage complex is associated with a significant loss of both pronation and supination torque. Level of evidence: Case series, Level IV.


2021 ◽  
Vol 49 (02) ◽  
pp. e97-e104
Author(s):  
Ignacio Miranda ◽  
Francisco J. Lucas ◽  
Vicente Carratalá ◽  
Joan Ferràs-Tarragó ◽  
Francisco J. Miranda

Abstract Introduction Peripheral injuries of the triangular fibrocartilage complex (TFCC) can produce pain and instability of the distal radioulnar joint (DRUJ). There are several techniques for the reconstruction of the TFCC. The aim of the present paper was to summarize the tendon plasties of the DRUJ ligaments for the anatomic reconstruction of TFCC, to analyze the surgical techniques, and to evaluate their outcomes. Methods In order to perform a systematic review, we searched in the literature the terms DRUJ instability OR chronic distal radioulnar joint instability OR distal radioulnar tendon plasty. Results In total, 11 articles with level of evidence IV (case series) were retrieved. Most studies achieved good results, with recovery of wrist stability, improvement of the pain, and increase in grip strength in the functionality tests. In the historical evolution of the published series, wrist surgeons tried to perform a more anatomical plasty, with a more stable fixation and less invasive techniques. Conclusion The Adams procedure continues to be a valid and reproducible technique for the treatment of chronic DRUJ instability. If wrist arthroscopy and implants are available and surgeons have been technically trained, the authors recommend an arthroscopy-assisted technique, or, if possible, an all-arthroscopic TFCC reconstruction with implant fixation of the plasty in its anatomical points of insertion. Comparative studies between open and arthroscopic TFCC reconstruction techniques are needed.