Interposition Technique for Pulmonary Valve Replacement

2021 ◽  
Vol 12 (3) ◽  
pp. 411-413
Author(s):  
Lok Sinha ◽  
Josue Chery ◽  
Richard A. Jonas ◽  
Pranava Sinha

Background: Stented bioprosthesis implant at surgical pulmonary valve replacement (PVR) ideally should be 25 to 27 mm to facilitate future percutaneous PVR. This often requires accommodating 35 to 37 mm diameter sewing ring in the pulmonary position and requires anterior patch augmentation of the right ventricular outflow tract (RVOT). We present a novel “interposition” technique of PVR that allows upsizing the valve without RVOT patch augmentation. Methods: Using standard cardiopulmonary bypass, the main pulmonary artery (MPA) is dissected and transected at an appropriate level. The remnants of pulmonary valve leaflets are excised. The valve stent posts are telescoped into distal MPA, the MPA continuity is restored by end-to-end anastomosis of the proximal and distal MPA, with the interposed prosthetic valve sewing ring in the suture line between the two edges of the MPA with the bulk of the sewing ring extravascular. Result: A total of seven patients (tetralogy of Fallot, three; congenital pulmonary stenosis, four; age range: 15-33 years) underwent the procedure. No patient required RVOT patch augmentation, all patients were extubated in the operating room and were fast-tracked to recovery. Our proposed technique of PVR has the following advantages: accommodate larger size valve, eliminates risk of a paravalvar leak, coronary compression, and anterior tilting of the prosthesis. Conclusion: The valve interposition technique avoids the need for RVOT patch, allows implantation of an adequate sized prosthetic valve, maintains native geometry of the pulmonary artery without the risk of tilting of the prosthesis, and eliminates the risk of paravalvular regurgitation and left coronary compression.

Circulation ◽  
2018 ◽  
Vol 138 (Suppl_1) ◽  
Author(s):  
Veronica Toro Arana ◽  
Frandics Chan ◽  
Nicole Shiavone ◽  
Doff McElhinney ◽  
Sushma Reddy ◽  
...  

Introduction: Patients with Tetralogy of Fallot who had pulmonary valve replacement (PVR) are at risk for prosthetic valve failure that requires repeated valve replacement. Hypothesis: We hypothesize that the pre-operative geometry of the right ventricular outflow tract (RVOT) and the central pulmonary arteries is a predictor of future prosthetic valve dysfunction. Methods: In a retrospective study, using pre-operative cardiac MRI, we measured morphologic parameters including bifurcation angles, length, major and minor diameters, area, and circumference in various locations along the RVOT, pulmonary trunk (PT) and branch pulmonary arteries (BPAs) in 48 patients with Tetralogy of Fallot before they underwent PVR. Physiologic data was collected from their imaging reports (age, weight, height, body surface area (BSA), ventricular volumes and ejection fractions, valvular regurgitant fractions). All measurements were normalized by the patients’ BSA. Post-operative pulmonary valve function was assessed using Echocardiograms performed at an average of 5.5 years after the surgery. Valve dysfunction was defined as pulmonary regurgitation and/or pulmonary stenosis of at least moderate intensity. All geometric and physiologic parameters were compared between the group of patients who developed pulmonary valve dysfunction and those who did not, using a two-tailed Student t-test. Results: Patients who developed valve dysfunction had (1) greater RVOT circumference (p=0.038), (2) a more acute bifurcation angle between the PT and the Left Pulmonary Artery (p=0.016), and (3) smaller cross-sectional area at the distal BPAs (p=0.031, p=0.026). Conclusions: A dilated RVOT leading to flow vortices may increase the shear stress experienced by the valve, a sharp bifurcation angle disrupts flow patterns, adding dynamic load to the valve, and stenosis in the distal BPAs lead to increased resistance and an increased volume load to the valve - all promoting valve degeneration. Our findings are consistent with physiologic expectations and will be further explored using computational fluid dynamic simulations to elucidate how the parameters identified impact the hemodynamics around the pulmonary valve. A deeper understanding of the hemodynamic implications may ultimately reduce the incidence of valve degeneration by helping surgeons identify patients who are at high risk for valve dysfunction and guiding them to reconstruct the RVOT in specific configurations.


2021 ◽  
Vol 12 (5) ◽  
pp. 643-648
Author(s):  
Ignacio Lugones ◽  
Jesús Damsky Barbosa ◽  
Guillermo Schvartz ◽  
Judith Ackerman ◽  
Verónica Laudani ◽  
...  

Transcatheter pulmonary valve replacement has become an attractive alternative to surgical approach in patients with dysfunctional right ventricular outflow tract. However, in certain cases, an unfavorable anatomy might complicate optimal valve deployment and stability. Several techniques have been described to reshape the landing zone and allow proper implantation of the transcatheter valve. Among them, the hybrid approach has gained attention as an interesting method for off-pump pulmonary valve replacement in patients with dilated right ventricular outflow tract. But to date, there is no standardized method to resize and reshape the landing zone for the stented valve. Here, we describe a reproducible method based on simple geometric rules to allow adequate remodeling of the main pulmonary artery to the desired dimensions in a single attempt, followed by perventricular implantation of a Venus P-valve.


2014 ◽  
Vol 9 (1) ◽  
pp. 54-55
Author(s):  
Rezwanul Haque Bulbul ◽  
Omar Sadeque Khan ◽  
Mohammad Samir Azam Sunny ◽  
Swadesh Ranjan Sarker ◽  
Mostafa Nuruzzaman

Pulmonary valve replacement for pulmonary regurgitation is a common practise. Pulmonary stenosis relief or after release of right ventricular outflow tract obstruction, progressive pulmonary regurgitation leading to biventricular failure is a big problem. If early pulmonary valve replacement done by homograft or tissue valve then we can overcome this problem. In our case report we have done pulmonary valve replacement by Edward life science Tissue valve for calcified pulmonary valve. And our patient showed a good response after valve replacement. DOI: http://dx.doi.org/10.3329/uhj.v9i1.19514 University Heart Journal Vol. 9, No. 1, January 2013; 54-55


Sign in / Sign up

Export Citation Format

Share Document