scholarly journals Diagnostic yield of colon capsule endoscopy for Crohn’s disease lesions in the whole gastrointestinal tract

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Keisaku Yamada ◽  
Masanao Nakamura ◽  
Takeshi Yamamura ◽  
Keiko Maeda ◽  
Tsunaki Sawada ◽  
...  

Abstract Background Crohn’s disease (CD) can involve the upper gastrointestinal (GI) tract as well as the small and large bowel. PillCam colon capsule endoscopy (PCCE-2) enables observation of the whole GI tract, but its diagnostic yield for CD lesions in the whole GI tract remains unknown. Aim To elucidate the diagnostic yield of PCCE-2 in patients with CD. Methods Patients with CD who underwent PCCE-2 and double-balloon endoscopy (DBE) using oral and anal approaches were evaluated for CD lesions in the whole GI tract. We divided the small bowel into three segments (jejunum, ileum, and terminal ileum), and the large bowel into four segments (right colon, transverse colon, left colon, rectum). Detection of ulcer scars, erosion, ulcers, bamboo joint-like appearance, and notch-like appearance was assessed in each segment. The diagnostic yield of PCCE-2 was analyzed based on the DBE results as the gold standard. Results Of the total 124 segments, the sensitivities of PCCE-2 for ulcer scars, erosion, and ulcers were 83.3%, 93.8%, and 88.5%, respectively, and the specificities were 76.0%, 78.3%, and 81.6%, respectively. For the 60 small bowel segments, the sensitivities were 84.2%, 95.5%, and 90.0%, respectively, and the specificities were 63.4%, 86.8%, and 87.5%, respectively. For the 64 large bowel segments, the sensitivities were 80.0%, 90.0%, and 83.3%, respectively, and the specificities were 84.7%, 72.2%, and 77.6%, respectively. Conclusion PCCE-2 provides a high diagnostic yield for lesions in the whole GI tract of patients with CD. Thus, we recommend its use as a pan-enteric tool in clinical settings.

2020 ◽  
Author(s):  
Keisaku Yamada ◽  
Masanao Nakamura ◽  
Takeshi Yamamura ◽  
Keiko Maeda ◽  
Tsunaki Sawada ◽  
...  

Abstract BACKGROUNDCrohn’s disease (CD) can involve the upper gastrointestinal (GI) tract as well as the small and large bowel. PillCam colon capsule endoscopy (PCCE-2) enables to observe the whole GI tract, but its diagnostic yield for CD lesions in the whole GI tract remains unknown. AIMTo elucidate the diagnostic yield of PCCE-2 in patients with CD.METHODSPatients with CD who underwent PCCE-2 and double-balloon endoscopy (DBE) using oral and anal approaches were evaluated for CD lesions in the whole GI tract. We divided the small bowel into three segments (jejunum, ileum, and terminal ileum), and the large bowel into four segments (right colon, transverse colon, left colon, rectum). Detection of ulcer scars, erosion, ulcers, bamboo joint-like appearance, and notch-like appearance was assessed in each segment. The diagnostic yield of PCCE-2 was analyzed based on the DBE results as the gold standard.RESULTSOf the total 124 segments, the sensitivities of PCCE-2 for ulcer scars, erosion, and ulcers were 83.3%, 93.8%, and 88.5%, respectively, and the specificities were 76.0%, 78.3%, and 81.6%, respectively. For the 60 small bowel segments, the sensitivities were 84.2%, 95.5%, and 90.0%, respectively, and the specificities were 63.4%, 86.8%, and 87.5%, respectively. For the 64 large bowel segments, the sensitivities were 80.0%, 90.0%, and 83.3%, respectively, and the specificities were 84.7%, 72.2%, and 77.6%, respectively.CONCLUSIONPCCE-2 provides a high diagnostic yield for lesions in the whole GI tract of patients with CD. Thus, we recommend its use as a pan-enteric tool in clinical settings.


2015 ◽  
Vol 81 (5) ◽  
pp. AB172
Author(s):  
Salvatore Oliva ◽  
Fortunata Civitelli ◽  
Emanuele Casciani ◽  
Francesca Maccioni ◽  
Giovanni Di Nardo ◽  
...  

2016 ◽  
Vol 83 (5) ◽  
pp. 975-983 ◽  
Author(s):  
Salvatore Oliva ◽  
Salvatore Cucchiara ◽  
Fortunata Civitelli ◽  
Emanuele Casciani ◽  
Giovanni Di Nardo ◽  
...  

2015 ◽  
Vol 148 (4) ◽  
pp. S-827
Author(s):  
Begoña Gonzalez Suarez ◽  
Cristina Rodriguez de Miguel ◽  
Cristina Romero ◽  
Ingrid Ordás ◽  
Aranzazu Jauregui-Amezaga ◽  
...  

2017 ◽  
Vol 85 (5) ◽  
pp. AB283
Author(s):  
Salvatore Oliva ◽  
Salvatore Cucchiara ◽  
Fortunata Civitelli ◽  
Marina Aloi ◽  
Franca Viola ◽  
...  

Diagnostics ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 2240
Author(s):  
Soo-Young Na ◽  
Yun-Jeong Lim

Capsule endoscopy (CE) has proven to be a valuable diagnostic modality for small bowel diseases over the past 20 years, particularly Crohn’s disease (CD), which can affect the entire gastrointestinal tract from the mouth to the anus. CE is not only used for the diagnosis of patients with suspected small bowel CD, but can also be used to assess disease activity, treat-to-target, and postoperative recurrence in patients with established small bowel CD. As CE can detect even mildly non-specific small bowel lesions, a high diagnostic yield is not necessarily indicative of high diagnostic accuracy. Moreover, the cost effectiveness of CE as a third diagnostic test employed usually after ileocolonoscopy and MR or CT enterography is an important consideration. Recently, new developments in colon capsule endoscopy (CCE) have increased the utility of CE in patients with ulcerative colitis (UC) and pan-enteric CD. Although deflation of the colon during the examination and the inability to evaluate dysplasia-associated lesion or mass results in an inherent risk of overestimation or underestimation, the convenience of CCE examination and the risk of flare-up after colonoscopy suggest that CCE could be used more actively in patients with UC.


Sign in / Sign up

Export Citation Format

Share Document