The Treatment of Patellar Fracture with Modified Tension Band Wiring, using Cannulated Screws

2004 ◽  
Vol 17 (2) ◽  
pp. 117 ◽  
Author(s):  
Chul Won Ha ◽  
Jong Il Sun
1993 ◽  
Vol 7 (3) ◽  
pp. 252-260 ◽  
Author(s):  
L K Hung ◽  
S Y Lee ◽  
K S Leung ◽  
K M Chan ◽  
Leslie A. Nicholl

Medicine ◽  
2020 ◽  
Vol 99 (12) ◽  
pp. e19576
Author(s):  
Tiecheng Yu ◽  
Zhendong Wu ◽  
Sayid Omar Mohamed ◽  
Weina Ju ◽  
Xiuxin Liu ◽  
...  

Cases Journal ◽  
2009 ◽  
Vol 2 (1) ◽  
Author(s):  
Michael T Hirschmann ◽  
Björn Wind ◽  
Christian Mauch ◽  
Gesa Ickler ◽  
Niklaus F Friederich

2018 ◽  
Vol 26 (3) ◽  
pp. 230949901878970 ◽  
Author(s):  
Chih-Wei Chang ◽  
Yen-Nien Chen ◽  
Chun-Ting Li ◽  
Yu-Hsuan Chung ◽  
Chih-Han Chang ◽  
...  

Purpose: Clinical and biomechanical studies have reported that using supportive screws and a wire instead of the common Kirschner wires for modified tension band wiring improves the stability of fractured patellae. However, the effect of screw proximity on the fixation of a fractured patella remains unclear. Therefore a numerical study was conducted to examine the effects of screw proximity on biomechanical responses in a simulated patellar fracture fixed using two parallel cannulated screws and anterior tension band wiring. Methods: A patellar model with a transverse fracture and loads simulating patellar tendon forces applied on the patella were used in the present simulation. The surgical fixation consisted of two 4.0-mm parallel partially threaded cannulated screws with a figure-of-eight tension band made using a 1.25-mm stainless steel wire. Biomechanical responses at two screw proximities, 5 and 10 mm from the leading edge of the patella, were investigated. Results: Superficial screw placement (5 mm) yielded higher stability, lower wire loads, and lower bone contact pressures than the deep placement (10 mm). The deep placement of screws exerted a higher load on the wire but a lower force on the screw than superficial placement did. Conclusion: This is the first numerical study to examine the effects of screw location on the fixation of a fractured patella using cannulated screws and tension band wiring. Considering the favorable biomechanical responses, superficial placement (5 mm below the leading edge of the patella) is recommended for screw insertion when treating a transverse fractured patella.


2012 ◽  
Vol 21 (2) ◽  
pp. 311-317 ◽  
Author(s):  
Simon Thelen ◽  
Johannes Schneppendahl ◽  
Ralf Baumgärtner ◽  
Christian Eichler ◽  
Jürgen Koebke ◽  
...  

1999 ◽  
Vol 48 (1) ◽  
pp. 110-114 ◽  
Author(s):  
Takuya Ikuta ◽  
Taisuke Kitamura ◽  
Chikahiro Takita

Sign in / Sign up

Export Citation Format

Share Document