The biomechanical performance of locking plate fixation with intramedullary fibular strut graft augmentation in the treatment of unstable fractures of the proximal humerus

2011 ◽  
Vol 93-B (7) ◽  
pp. 937-941 ◽  
Author(s):  
J.-H. Bae ◽  
J.-K. Oh ◽  
C.-S. Chon ◽  
C.-W. Oh ◽  
J.-H. Hwang ◽  
...  
2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Fu Wang ◽  
Yan Wang ◽  
Jinye Dong ◽  
Yu He ◽  
Lianxin Li ◽  
...  

Abstract Background and hypothesis The typical anterolateral approach is widely used to treat proximal humerus fractures with lateral locking fixation. However, lateral fixation cannot completely avoid medial reduction loss and varus deformity especially in the cases of an unstable medial column. We present a novel medial surgical approach and technique together with a minimally invasive lateral locking plate to fix proximal humerus fractures with an unstable medial column. Materials and methods We performed an anatomical study and reported 8 cases of proximal humerus fractures with unstable medial columns treated with plate fixation through a minimally invasive anterolateral approach and medial approach. All surgeries were performed by the same single surgeon. Patients were followed clinically and radiographically at 1, 3, 6, and 12 months postoperatively. Results There was a safe region located at the medial part of the proximal humerus just beneath the articular surface. An anatomical medial locking proximal humerus plate could be placed in the medial column and did not affect the axillary nerve, blood supply of the humeral head, or stability of the shoulder joint. Successful fracture healing was achieved in all 8 cases. The function and range of motion of the shoulder joint were satisfactory 24 months postoperatively, with an average Constant score (CS) of 82.8. No reduction loss (≥ 10° in any direction), screw cutout, nonunion, or deep infection occurred. Conclusions The combined application of medial anatomical locking plate fixation and minimally invasive lateral locking plate fixation is effective in maintaining operative reduction and preventing varus collapse and implant failure in proximal humerus fractures with an unstable medial column.


Injury ◽  
2011 ◽  
Vol 42 (4) ◽  
pp. 408-413 ◽  
Author(s):  
Robert C. Sproul ◽  
Jaicharan J. Iyengar ◽  
Zlatko Devcic ◽  
Brian T. Feeley

2019 ◽  
Author(s):  
Xueliang Cui ◽  
Hui chen ◽  
Binbin Ma ◽  
Wenbin Fan ◽  
He Li

Abstract Purpose: The purpose of this study was to determine if fibular strut allograft influence reduction and clinical outcomes after locking plate fixation of comminuted proximal humeral fractures (PHFs). Methods: A retrospective review was performed on sixty 3- and 4-part PHFs treated with either locking plate only or locking plate with a fibular allograft. Fracture reduction was quantitatively determined by humeral head height (HHH) and neck-shaft angle (NSA). Loss of anatomic fixation was defined if the varus malalignment of neck-shaft angle (NSA) was more than 5°or if the change of humeral head height (HHH) was more than 3 mm. Clinical outcome was evaluated by Constant-Murley score (CMS) and American Shoulder and Elbow Surgeons (ASES) score. Result: The average radiological changes were higher in the locking compression plate (LCP) group than in the locking plate with fibular allograft (FA) group ( HHH of 4.16mm versus 1.18mm [p﹤0.001] and NSA of 9.94° versus 3.12° [p﹤0.001 ]). Final average outcome scores were lower in LCP group than in FA group ( CMS of 73.00 versus 78.96 [p = 0.024] and ASES score of 72.80 versus 78.64 [p = 0.022]). FA group showed better forward elevation (P=0.010) and abduction (P=0.002), but no significant differences were observed for shoulder external rotation or internal rotation. Conclusion: For comminuted proximal humerus fractures in elderly patients with severe osteoporosis, locking plate fixation with a fibular strut allograft showed satisfactory radiological and clinical outcomes. Key words: proximal humeral fractures; locking compression plate; fibular allograft


Author(s):  
Christoph J. Laux ◽  
Florian Grubhofer ◽  
Clément M. L. Werner ◽  
Hans-Peter Simmen ◽  
Georg Osterhoff

2008 ◽  
Vol 9 (1) ◽  
Author(s):  
Chlodwig Kirchhoff ◽  
Volker Braunstein ◽  
Sonja Kirchhoff ◽  
Christoph M Sprecher ◽  
Ben Ockert ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document