scholarly journals Microwave-photonic Low-coherence Interferometry for Dark Zone Free Distributed Optical Fiber Sensing

2021 ◽  
Author(s):  
Xuran Zhu ◽  
Liwei Hua ◽  
Jincheng Lei ◽  
Jianan Tang ◽  
Lawrence Murdoch ◽  
...  
2017 ◽  
Vol 25 (25) ◽  
pp. 31362 ◽  
Author(s):  
Liwei Hua ◽  
Yang Song ◽  
Baokai Cheng ◽  
Wenge Zhu ◽  
Qi Zhang ◽  
...  

2019 ◽  
Vol 66 (1) ◽  
pp. 299-305 ◽  
Author(s):  
Diego Di Francesca ◽  
Angelo Infantino ◽  
Gaetano Li Vecchi ◽  
Sylvain Girard ◽  
Antonino Alessi ◽  
...  

2021 ◽  
Author(s):  
Jian Li ◽  
Xinxin Zhou ◽  
Yang Xu ◽  
Lijun Qiao ◽  
Jianzhong Zhang ◽  
...  

Sensor Review ◽  
2021 ◽  
Vol 41 (4) ◽  
pp. 350-360
Author(s):  
Xiao Fang ◽  
Yajie Zeng ◽  
Feng Xiong ◽  
Jiang Chen ◽  
Fei Cheng

Purpose Seepage of the dam is an important safety problem, which may cause internal erosion of the structure. In the field of seepage monitoring in civil engineering, the distributed optical fiber sensing technology based on the temperature tracing method has been paid more attention due to its unique advantages of high sensitivity, good stability and high resolution. The purpose of this paper is to make a review of the existing related research, so as to facilitate the later scholars to understand and further study more systematically. Design/methodology/approach In this paper, three kinds of commonly used distributed fiber temperature measurement technologies are introduced. Based on the working principle, monitoring system, theoretical analysis, experimental research and engineering application of the fiber seepage monitoring technology, the present situation of dam seepage monitoring based on distributed fiber is reviewed in detail and their advantages and disadvantages are compared. Findings The thermal monitoring technology of seepage measurement depends on the accuracy of optical fiber temperature measurement (including the accuracy of the system and the rationality of the discrimination method), the correct installation of optical fiber and the quantitative analysis of temperature data. The accuracy of the current monitoring system can basically meet the existing measurement requirements, but the correct installation of optical fiber and the calibration of temperature data need to be further studied for different discrimination methods, and this field has great research value. Originality/value At present, there are many applications and research studies of optical fiber sensing in the field of structural health monitoring, and there are also reviews of related aspects. However, there is little or no review only in the field of seepage monitoring. This paper summarizes the research and application of optical fiber sensing in the field of seepage monitoring. The possibility of the gradient method to find its new prospect with the development of monitoring systems and the improvement of temperature resolution is discussed. The idea of extending the seepage monitoring method based on distributed optical fiber thermal monitoring technology to other monitoring fields is also given in the paper.


Sign in / Sign up

Export Citation Format

Share Document