The influence of the form error and rough datum surface position on the accuracy of manufacturing of the “box-type product”

2021 ◽  
Vol 2021 (12) ◽  
pp. 37-43
Author(s):  
Aleksandr Yamnikov ◽  
Evgeniy Danilenko
Keyword(s):  

The influence of the form error and rough datum surface position on the accuracy of manufacturing parts of reduced rigidity is considered. A sketch diagram of the allocation of technological zones is presented. A new method for allocating technological zones is proposed.

Author(s):  
Hidetaka Fujii ◽  
Takashi Onishi ◽  
Chinhu Lin ◽  
Moriaki Sakakura ◽  
Kazuhito Ohashi

Abstract In the case of traverse grinding of a slender workpiece, the ground workpiece is easily deformed by the normal grinding force due to its low stiffness. To reduce the form error caused by the elastic deformation of the workpiece, a steady rest is widely used. Generally, a steady rest is set to push the ground area of the workpiece. However, the stepped shape error is generated at the contact point where a steady rest pushed the workpiece because the pushing force of a steady rest is decreased after the material of the contact point is removed. In this study, to reduce the stepped shape error of the ground workpiece, we proposed a new method to set a steady rest. In this method, the steady rest was set to push the area where was not ground. In addition, the traverse speed of the workpiece was adjusted to keep the elastic deformation of the workpiece constant. The suitable method to control the traverse speed was estimated by using a beam model that could simulate the elastic deformation of the workpiece during the grinding process. It was confirmed that the new method could improve the form accuracy of a slender workpiece through grinding experiments.


Author(s):  
C. C. Clawson ◽  
L. W. Anderson ◽  
R. A. Good

Investigations which require electron microscope examination of a few specific areas of non-homogeneous tissues make random sampling of small blocks an inefficient and unrewarding procedure. Therefore, several investigators have devised methods which allow obtaining sample blocks for electron microscopy from region of tissue previously identified by light microscopy of present here techniques which make possible: 1) sampling tissue for electron microscopy from selected areas previously identified by light microscopy of relatively large pieces of tissue; 2) dehydration and embedding large numbers of individually identified blocks while keeping each one separate; 3) a new method of maintaining specific orientation of blocks during embedding; 4) special light microscopic staining or fluorescent procedures and electron microscopy on immediately adjacent small areas of tissue.


1960 ◽  
Vol 23 ◽  
pp. 227-232 ◽  
Author(s):  
P WEST ◽  
G LYLES
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document