Selective Sampling and Orientation of Non-Homogeneous Tissues

Author(s):  
C. C. Clawson ◽  
L. W. Anderson ◽  
R. A. Good

Investigations which require electron microscope examination of a few specific areas of non-homogeneous tissues make random sampling of small blocks an inefficient and unrewarding procedure. Therefore, several investigators have devised methods which allow obtaining sample blocks for electron microscopy from region of tissue previously identified by light microscopy of present here techniques which make possible: 1) sampling tissue for electron microscopy from selected areas previously identified by light microscopy of relatively large pieces of tissue; 2) dehydration and embedding large numbers of individually identified blocks while keeping each one separate; 3) a new method of maintaining specific orientation of blocks during embedding; 4) special light microscopic staining or fluorescent procedures and electron microscopy on immediately adjacent small areas of tissue.

Development ◽  
1984 ◽  
Vol 80 (1) ◽  
pp. 321-330
Author(s):  
Jonathan M. W. Slack

The development of ectoderm isolated from the animal pole of axolotl gastrulae is monitored by light microscopy, electron microscopy and analysis of newly synthesized proteins, glycoproteins and glycolipids. When control embryos are undergoing neurulation it is shown that the explants autonomously begin to express epidermal markers and do not express mesodermal markers. However the results suggest that not all the cells become epidermal and electron microscope examination shows that only the outer layer does so, the inner cells remaining undifferentiated.


Author(s):  
George Guthrie ◽  
David Veblen

The nature of a geologic fluid can often be inferred from fluid-filled cavities (generally <100 μm in size) that are trapped during the growth of a mineral. A variety of techniques enables the fluids and daughter crystals (any solid precipitated from the trapped fluid) to be identified from cavities greater than a few micrometers. Many minerals, however, contain fluid inclusions smaller than a micrometer. Though inclusions this small are difficult or impossible to study by conventional techniques, they are ideally suited for study by analytical/ transmission electron microscopy (A/TEM) and electron diffraction. We have used this technique to study fluid inclusions and daughter crystals in diamond and feldspar.Inclusion-rich samples of diamond and feldspar were ion-thinned to electron transparency and examined with a Philips 420T electron microscope (120 keV) equipped with an EDAX beryllium-windowed energy dispersive spectrometer. Thin edges of the sample were perforated in areas that appeared in light microscopy to be populated densely with inclusions. In a few cases, the perforations were bound polygonal sides to which crystals (structurally and compositionally different from the host mineral) were attached (Figure 1).


1963 ◽  
Vol 16 (4) ◽  
pp. 768 ◽  
Author(s):  
MS Buttrose

The developing aleurone layer cells of the wheat kernel have been investigated by electron microscopy and the results compared with those of light microscopy. Two weeks after flowering vacuoles appear in the cells and deposits accumulate in these until maturity when the cells are filled 'with the resulting "vacuolar units" 2-3p. in diameter, corresponding to the aleurone grains of light microscopy. The wheat aleurone grain consists of a bounding membrane (of vacuole origin) enclosing a matrix in which are embedded spherical deposits. Some of these deposits are translucent and others opaque to electrons after potassium permanganate and osmium tetroxide fixation. At all stages examined the cytoplasm of aleurone cells contained large numbers of small unidentified bodies with irregular outline and dense contents. At first they are dispersed, but towards maturity are organized as a monolayer over the surface of each aleurone grain and the inner surface of the cell walls. The apparent specificity of these structures to aleurone cells is discussed in relation to future chemical and physiological studies of the tissue.


Although much is known about the structural organization and connexions of the various lobes of the octopus brain from light microscopy, this is the first attempt at a detailed analysis of one of the lobes— the vertical lobe, with the electron microscope. The vertical lobe consists of five lobules. The median superior frontal (MSF) axons enter each lobule from the MSF lobe. The MSF axons contain both microtubules and neurofilaments. The varicosities of the MSF axons contain both agranular and dense-cored vesicles and synapse with trunks of the amacrine cells. These trunks run together in bundles termed amacrine tracts into the centres of the lobules. The amacrine trunks contain microtubules but no neurofilaments. The trunks contain large and small agranular synaptic vesicles and synapse with what are in all probability branches of the trunks of the large cells. These trunks contain microtubules but no neurofilaments. They run out through the bases of the lobules probably without forming synaptic contacts within the lobule. Fibres signalling ‘pain’ (nocifensor) enter the lobules from below. They can be recognized by their content of neurofilaments. Their terminals contain numerous very small synaptic vesicles and a few larger and dense-cored ones. These ‘pain’ fibres appear to synapse mostly with processes of the large cells. J. Z. Young has shown that the vertical lobe is especially concerned with the integrative action of the visual system, linked with the chemo-tactile system. Electron microscopy supports Young’s suggestion that the superior frontal and interconnected vertical lobe systems constitute a loop which could sustain a positive feed-back mechanism (MSF —> amacrine -> large cell -> lateral superior frontal -> MSF) while the ‘pain’ (nocifensor) input could exert a suppressor (inhibitory) effect on the loop by its action on the large cells.


1992 ◽  
Vol 62 (7) ◽  
pp. 423-431 ◽  
Author(s):  
F.-J. Wortmann ◽  
G. Wortmann

Labeling textile blends requires identification and quantification of their fibrous components. Blends of specialty animal fibers with sheep's wool are of special, practical importance; for these the light microscope is the traditional tool of analysis. To investigate the actual applicability of light microscopy for analyzing such blends as an alternative to the scanning electron microscope (SEM), we analyzed in detail the results of round trials conducted in the seventies. The results confirm that light microscopy, in general, is neither an objective nor a reproducible method for analyzing wool/specialty fiber blends. Though there was substantial progress with subsequent round trials, the data suggest that there is a fundamental statistical limit to the pass/fail rate, i.e., the ratio of correct versus incorrect analyses in a round trial that can be achieved by light microscopy. Even allowing for generous error limits, this effect leaves an intolerable element of chance for the correctness of analysis. Such performance is in pronounced contrast to that of the SEM method, where round trials have shown that laboratories that perform well reach analysis errors for specialty fiber/wool blends that are within or close to the natural error limits of microscopic analyses.


1981 ◽  
Vol 64 (1) ◽  
pp. 199-224
Author(s):  
John E Kvenberg

Abstract Larval stored product beetle mandibles were studied by comparing images made by scanning electron microscopy with those made by conventional light microscopy. Discussion of morphological characteristics is based on illustrations of 25 species


Author(s):  
Mark E. Gettner ◽  
Myron C. Ledbetter ◽  
Philip S. Woods

Our objective is to take advantage of the resolving power of the scanning electron microscope (SEM) to study details of karyotype morphology for which the light microscope is limited. To the best of our knowledge the SEM has not been used to study karyotypes. To demonstrate the feasibility of this, we chose initially to examine a standard method used in light microscopy, namely the Carnoy-fixed peripheral lymphocyte chromosome technique that has found such universal favor (1), and to modify it for SEM observation. Methods were devised to permit observation and indexing by light microscopy prior to SEM observation. We report here our preliminary results using cells smeared on subbed slides then osmium ligated, and cells smeared on aluminum coated glass without metal staining. Both types of preparations were Giemsa stained and were observed uncoated.


Development ◽  
1958 ◽  
Vol 6 (1) ◽  
pp. 149-161
Author(s):  
Ruth Bellairs

In almost all embryos yolk becomes converted into cytoplasm. It has not previously been possible to describe in any detail the morphological changes involved in this process; indeed, when the yolk drops contained within embryonic cells are examined by light microscopy they seem to remain in much the same condition until they are suddenly used up. For this reason they have frequently been considered to be nothing but ‘inert, inactive’ stores of food. By using an electron microscope, however, it has been possible to trace some of the morphological changes which take place in the chick when intra-cellular yolk drops are converted into cytoplasm, and to show that these are not confined to a single stage of embryonic development. Moreover, the discovery of mitochondria within the yolk drops suggests that the yolk drops are not ‘inert’. The following stages have been examined: medium and long primitive streak (as defined by Waddington, 1932, and Abercrombie, 1950), head process, head fold, and 10–16 pairs of somites.


1994 ◽  
Vol 27 (5) ◽  
pp. 762-766 ◽  
Author(s):  
Q. Liu

With aid of a transmission-electron-microscope (TEM) double-tilt holder, a method for determining the normals to planar structures and their traces in a TEM is developed. This method is considered to be simple and convenient when compared with other methods. The accuracy of the method for the determination of both the normals to planar structures and their traces is within 2°.


Sign in / Sign up

Export Citation Format

Share Document