scholarly journals Diagnostic Performance of 18F-FDG PET or PET/CT for Detection of Post-Transplant Lymphoproliferative Disorder: A Systematic Review and a Bivariate Meta-Analysis

Diagnostics ◽  
2020 ◽  
Vol 10 (2) ◽  
pp. 101
Author(s):  
Veronika Ballova ◽  
Barbara Muoio ◽  
Domenico Albano ◽  
Francesco Bertagna ◽  
Luca Canziani ◽  
...  

Background: Some studies evaluated the diagnostic performance of fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography or positron emission tomography/computed tomography (PET or PET/CT) for the detection of post-transplant lymphoproliferative disorder (PTLD). As there is no clear consensus about the diagnostic accuracy of these imaging methods, we performed a meta-analysis on this topic. Methods: A comprehensive computer literature search of PubMed, Embase, and Cochrane library databases through December 2019 was performed. Pooled sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR−), and diagnostic odds ratio (DOR) of 18F-FDG PET or PET/CT for detection of PTLD were calculated. Results: Five studies reporting data on the diagnostic performance of 18F-FDG PET or PET/CT in 336 transplant recipients were included in the systematic review and bivariate meta-analysis. Pooled sensitivity and specificity for detection of PTLD were 89.7% (95% confidence interval (95%CI): 84.6–93.2%) and 90.9% (95%CI: 85.9–94.3%), respectively. Pooled LR+, LR−, and DOR were 8.9 (95%CI: 5.7–14), 0.13 (95%CI: 0.08–0.2), and 70.4 (95%CI: 35.4–140), respectively. A significant heterogeneity among studies was not detected. Conclusions: Despite limited literature data, 18F-FDG PET or PET/CT demonstrated good diagnostic performance for the detection of PTLD, but large prospective studies are needed to strengthen these findings.

2020 ◽  
Vol 13 (11) ◽  
pp. 377
Author(s):  
Salvatore Annunziata ◽  
Roberto C. Delgado Bolton ◽  
Christel-Hermann Kamani ◽  
John O. Prior ◽  
Domenico Albano ◽  
...  

Some recent studies evaluated the role of fluorine-18 fluorodeoxyglucose (2-[18F]FDG) as a radiopharmaceutical for positron emission tomography/computed tomography (PET/CT) imaging in patients with Coronavirus Disease (COVID-19). This article aims to perform a systematic review in this setting. A comprehensive computer literature search in PubMed/MEDLINE and Cochrane library databases regarding the role of 2-[18F]FDG PET/CT in patients with COVID-19 was carried out. This combination of key words was used: (A) “PET” OR “positron emission tomography” AND (B) “COVID” OR “SARS”. Only pertinent original articles were selected; case reports and very small case series were excluded. We have selected 11 original studies of 2-[18F]FDG PET/CT in patients with COVID-19. Evidence-based data showed first preliminary applications of this diagnostic tool in this clinical setting, with particular regard to the incidental detection of interstitial pneumonia suspected for COVID-19. To date, according to evidence-based data, 2-[18F]FDG PET/CT cannot substitute or integrate high-resolution CT to diagnose suspicious COVID-19 or for disease monitoring, but it can only be useful to incidentally detect suspicious COVID-19 lesions in patients performing this imaging method for standard oncological and non-oncological indications. Published data about the possible role of 2-[18F]FDG PET/CT in patients with COVID-19 are increasing, but larger studies are warranted.


Author(s):  
Ishith Seth ◽  
Nimish Seth ◽  
Gabriella Bulloch ◽  
Adrian Siu ◽  
Allen Guo ◽  
...  

Purpose: The aim of this study was to evaluate the diagnostic accuracy of 18-fluorodeoxyglucose-positron emission tomography (18F-FDG-PET) and positron emission tomography/computed tomography (PET/CT) in imaging primary and metastatic lesions in Ewing sarcoma (ES). Methods: PubMed, Cochrane, Scopus, and Web of Science were searched for relevant studies. Data concerning 18F-FDG-PET/CT diagnostic accuracy were extracted and then analysed using Open Meta-analyst software. Reported diagnostic accuracy outcomes included sensitivity, specificity, negative likelihood ratio (NLR), positive likelihood ratio (PLR), and diagnostic odds ratio. Results: 31 studies with a total of 735 patients were included in this meta-analysis. The sensitivity and specificity of 18F-FDG PET/CT were: 92.6% and 74.1% for total ES lesions, 96.7% and 68.3% for ES primary lesions, 76.1% and 92.4% for lung metastasis, 83.9% and 93.2% for bone metastasis and 89.9% and 92.6% for ES recurrence respectively. Conclusion: 18F-FDG PET/CT is sensitive and accurate in diagnosing, staging, and detecting the recurrence of ES compared to non-PET imaging. It has high specificity for diagnosing recurrence of ES as well as lung and bone metastases.


2021 ◽  
Vol 5 (1) ◽  
pp. 1151-1160
Author(s):  
A.S. Lukashevich ◽  

Purpose. The purpose of the article is to evaluate the diagnostic significance of positron emission tomography / computed tomography with 18F -fluorodeoxyglucose (18F -FDG PET/CT) for the diagnosis of prosthetic endocarditis. Methods of research. The study included 82 patients with suspected prosthetic endocarditis in accordance with the criteria proposed by Duke University [1-5]. The patients received hospital treatment at the State Institution RSPC "Cardiology" from January 2016 to March 2021. The study was of a prospective, non-randomized, single-center cohort design. The duration of the monitor period was 12 months from the moment of patients’ inclusion in the study. Whole-body positron emission tomography / computed tomography (PET/CT) examinations were performed in 82 patients. 27 patients were selected for surgical treatment. Conservative treatment group included 16 patients. 27 patients were selected into the observation group, they were suspected to have prosthetic heart valve infection in the primary referral and underwent PET/CT scanning, according to which the diagnosis of prosthetic endocarditis was excluded. The event under the study did not develop in this group during the year of observation. Results and conclusion. The history of infective endocarditis was not statistically significant and did not increase the risk of developing prosthetic endocarditis in the sample presented. The Duke criteria are less reliable in establishing the diagnosis of prosthetic endocarditis. The median number of days from the date of the first prosthesis implantation to the onset of prosthetic endocarditis was about 4 years. This study revealed that the development of the infectious process in the area of the prosthesis was noted in a more distant postoperative period compared to literature data. Histological confirmation of infection was noted in 100% (27 patients) of cases in reoperated patients. The presence of a more formidable complication such as valve ring abscess located mainly in the projection of the aortic valve ring was quite common in both groups. Presepsin and Interleukin-6 have a statistically significant (U = 394,50 p = 0,01 and U = 94,50 p = 0.004) value in the prognosis of prosthetic endocarditis. Considering the data obtained from ROC analysis, it can be said that the cut-off point at which it is possible to diagnose prosthetic endocarditis based on PETCT is 2.85. The presented methods for the interpretation of whole-body FDG-PET/CT images of patients with suspected infectious complications after cardiac surgery, as well as with the presence of prosthetic endocarditis, show high sensitivity and specificity.


Diagnostics ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. 1042
Author(s):  
Annachiara Arnone ◽  
Riccardo Laudicella ◽  
Federico Caobelli ◽  
Priscilla Guglielmo ◽  
Marianna Spallino ◽  
...  

In this review, the performance of fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) in the diagnostic workup of pancreatic ductal adenocarcinoma (PDAC) is evaluated. A comprehensive literature search up to September 2020 was performed, selecting studies with the presence of: sample size ≥10 patients and index test (i.e., “FDG” or “18F-FDG” AND “pancreatic adenocarcinoma” or “pancreas cancer” AND “PET” or “positron emission tomography”). The methodological quality was evaluated using the revised quality assessment of diagnostic accuracy studies (QUADAS-2) tool and presented according to the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines. Basic data (authors, year of publication, country and study design), patients’ characteristics (number of enrolled subjects and age), disease phase, type of treatment and grading were retrieved. Forty-six articles met the adopted research criteria. The articles were divided according to the considered clinical context. Namely, besides conventional anatomical imaging, such as computed tomography (CT) and magnetic resonance imaging (MRI), molecular imaging with FDG PET/CT is an important tool in PDAC, for all disease stages. Further prospective studies will be necessary to confirm the cost-effectiveness of such imaging techniques by testing its real potential improvement in the clinical management of PDAC.


Medicina ◽  
2021 ◽  
Vol 57 (12) ◽  
pp. 1289
Author(s):  
Mio Mori ◽  
Kazunori Kubota ◽  
Tomoyuki Fujioka ◽  
Leona Katsuta ◽  
Yuka Yashima ◽  
...  

We used virtual navigator real-time ultrasound (US) fusion imaging with 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) to identify a lesion that could not be detected on the US alone in a preoperative breast cancer patient. Of the patient’s two lesions of breast cancer, the calcified lesion could not be identified by US alone. By fusing US with 18F-FDG PET/CT, which had been performed in advance, the location of the lesion could be estimated and marked, which benefited planning an appropriate surgery. The fusion of US and 18F-FDG PET/CT was a simple and noninvasive method for identifying the lesions detected by 18F-FDG PET/CT.


2019 ◽  
Vol 47 (5) ◽  
pp. 1287-1301 ◽  
Author(s):  
Giorgio Treglia ◽  
Mariarosa Pascale ◽  
Elena Lazzeri ◽  
Wouter van der Bruggen ◽  
Roberto C. Delgado Bolton ◽  
...  

2014 ◽  
Vol 2014 ◽  
pp. 1-11 ◽  
Author(s):  
Carmelo Caldarella ◽  
Salvatore Annunziata ◽  
Giorgio Treglia ◽  
Ramin Sadeghi ◽  
Narjes Ayati ◽  
...  

Purpose. The diagnostic performance of positron emission tomography using18F-fluorodeoxyglucose (FDG-PET) in detecting nodal involvement in patients with anal canal cancer (ACC) has been investigated by several studies with conflicting results. The aim of our study is to systematically review and meta-analyze published data about this topic.Methods. A comprehensive computer literature search of PubMed/MEDLINE, Scopus, and Embase databases was carried out on July 10 to find relevant articles concerning the diagnostic performance of FDG-PET in detecting locoregional nodal involvement in patients with ACC. No language restriction was used. Pooled diagnostic performance on a lesion-based analysis was calculated.Results. Seven retrospective and five prospective studies have been reviewed. Six studies allowed assessing pooled sensitivity; five studies allowed assessing pooled specificity. Sensitivity and specificity values of FDG-PET/CT on a lesion-based analysis ranged from 31 to 100% and from 53 to 98%, with pooled estimates of 56% (95% CI: 45–67%) and 90% (95% CI: 86–93%), respectively.Conclusions. Our meta-analysis demonstrates that FDG-PET is a specific diagnostic tool in detecting locoregional lymph node involvement in patients with ACC. Low sensitivity is a major concern; however, higher sensitivity could be reached combining FDG-PET with MR scan.


Sign in / Sign up

Export Citation Format

Share Document