scholarly journals Comparison of the Meibomian Gland Openings by Optical Coherence Tomography in Obstructive Meibomian Gland Dysfunction and Normal Patients

2020 ◽  
Vol 9 (10) ◽  
pp. 3181
Author(s):  
Xinhan Cui ◽  
Qingfan Wu ◽  
Zimeng Zhai ◽  
Yujing Yang ◽  
Anji Wei ◽  
...  

Purpose: The aim of this study was to use swept-source anterior segment optical coherence tomography (OCT) to explore imaging the meibomian gland openings and to identify their in vivo characteristics in patients with obstructive meibomian gland dysfunction (MGD) and healthy participants. Methods: We enrolled 49 patients with MGD and 54 health controls in this case-control study. Each participant underwent slit-lamp examination, meibography, and OCT scanning. Sixteen patients with MGD underwent a repeat OCT examination after eyelid massage. The outcome measures included determinations of meibomian gland openings (orifices and terminal ducts) from OCT images and comparisons of the meibomian openings between patients with MGD and normal controls before and after meibomian gland massage. Results: Using the same OCT scanning model, the number of visible orifices of the meibomian glands was similar between eyes with MGD and normal eyes (9.2 ± 2.3 vs. 9.7 ± 2.4). The mean diameter of the terminal ducts in patients with MGD was larger (120.22 ± 27.92 µm vs. 100.96 ± 20.30 µm) than in the normal controls, and had a larger coefficient of variation. Significant differences were observed in the mean diameter of the terminal ducts of patients with MGD before and after meibum gland massage (133.73 ± 27.81 μm vs. 102.26 ± 24.30 μm, p < 0.001). Conclusions: Patients with MGD have more diversified orifices and larger meibomian gland terminal duct diameters than normal subjects. In addition, meibomian gland terminal duct diameters seem to decrease in patients with MGD after meibum gland massage.

Author(s):  
Alireza Khodabande ◽  
Massood Mohammadi ◽  
Hamid Riazi-Esfahani ◽  
Shahab Karami ◽  
Massood Mirghorbani ◽  
...  

Abstract Background To evaluate changes in anterior segment morphology on anterior segment optical coherence tomography (AS-OCT) following pars plana vitrectomy (PPV) without tamponade. Methods Patients who underwent PPV without tamponade for epiretinal membrane were evaluated. Eligible patients underwent intraocular pressure (IOP) measurement and AS-OCT preoperatively as well as 1 month and 6 months post-operatively. Anterior chamber width (ACW), anterior chamber depth (ACD), trabecular iris angle (TIA), angle opening distance at 500 and 750 µm (AOD), and trabecular iris space area at 500 and 750 µm (TISA) at four quadrants were recorded and analyzed. Additionally, the mean values of TIA (MTIA), AOD (MAOD), and TISA (MTISA) for each eye (mean of four quadrants) were analyzed. Results 23 patients completed the study. The mean age of participants was 56.4 ± 3.6 years of age and 13/23 (56%) were female. Mean IOP of patients was 18.1 ± 1.1, 18.3 ± 1.1, and 18.1 ± 1.2 preoperatively,1 month post-operatively, and 6 months post-operatively, respectively. (p = 0.83). No difference was detected post-operatively in measurements of ACW, ACD, MTIA, MAOD500, MAOD750, MTISA500, and MTISA750. Conclusion Pars plana vitrectomy without tamponade was not associated with changes in anterior chamber morphology.


Cornea ◽  
2018 ◽  
Vol 37 (6) ◽  
pp. 785-788
Author(s):  
Aleksandra Petrovic ◽  
Kattayoon Hashemi ◽  
Frank Blaser ◽  
Wolfgang Wild ◽  
George Kymionis

2016 ◽  
Vol 100 (12) ◽  
pp. 1668-1675 ◽  
Author(s):  
Rodolfo Mastropasqua ◽  
Luca Agnifili ◽  
Vincenzo Fasanella ◽  
Lisa Toto ◽  
Lorenza Brescia ◽  
...  

Author(s):  
Sagili Chandrasekhara Reddy ◽  
Mohd Mansor Shariff ◽  
Aina Malindri Dasrilsyah

Purpose: To determine the central corneal thickness in myopic adult patients scheduled for laser corneal refractive surgery and to explore its correlation with degree of refractive error. Materials and Methods: The case records of 130 myopic patients who underwent laser corneal refractive surgery in a military hospital over a period of two years were reviewed to determine the central corneal thickness. All patients had 6/6 vision with best correction, and did not have any other anterior segment or fundus diseases in both eyes. The central corneal thickness was measured with Visante Carl Zeiss anterior segment optical coherence tomography instrument.                                                                                                                        Results: Out of 130 patients, males were more (73, 56.2%); mean age of patients was 33.8 years (range 18-60 years) and majority were Malays (110, 84.6%).  The spherical power of myopia ranged from – 0.5 to – 10.00 D, and the cylindrical power ranged from – 0.25 to – 3.25 D. The mean central corneal thickness of both eyes was 528.2 µm (range 331- 615 µm); in the mild degree of myopia (- 0.50 to - 2.00 D) 527.9 µm, moderate degree (- 2.25 to -5.00 D) 529.4 µm, and high degree (-5.25 to -11.00 D) 523.9 µm. Conclusion: The anterior segment optical coherence tomography provides noncontact, rapid, pachymetry mapping of the corneal thickness. In Malaysian patients, the mean central corneal thickness of both eyes in myopia was 528.1 µm (range 331- 615 µm). There was no correlation between the mean central corneal thickness and degree of myopia, different genders, age groups, ethnic groups and two eyes.


2017 ◽  
Vol 15 (4) ◽  
pp. 759-769 ◽  
Author(s):  
Anna Voskresenskaya ◽  
Nadezhda Pozdeyeva ◽  
Tatyana Vasilyeva ◽  
Yevgeniy Batkov ◽  
Aleksandr Shipunov ◽  
...  

2020 ◽  
Vol 245 (18) ◽  
pp. 1629-1636
Author(s):  
Ruiming Kong ◽  
Wenjuan Wu ◽  
Rui Qiu ◽  
Lei Gao ◽  
Fengxian Du ◽  
...  

Optical coherence tomography has become an indispensable diagnostic tool in ophthalmology for imaging the retina and the anterior segment of the eye. However, the imaging depth of optical coherence tomography is limited by light attenuation in tissues due to optical scattering and absorption. In this study of rabbit eye both ex vivo and in vivo, optical coherence tomography imaging depth of the anterior and posterior segments of the eye was extended by using optical clearing agents to reduce multiple scattering. The sclera, the iris, and the ciliary body were clearly visualized by direct application of glycerol at an incision on the conjunctiva, and the posterior boundary of sclera and even the deeper tissues were detected by submerging the posterior segment of eye in glycerol solution ex vivo or by retro-bulbar injection of glycerol in vivo. The ex vivo rabbit eyes recovered to their original state in 60 s after saline-wash treatment, and normal optical coherence tomography images of the posterior segment of the sample eyes proved the self-recovery of in vivo performance. Signal intensities of optical coherence tomography images obtained before and after glycerol treatment were compared to analysis of the effect of optical clearing. To the best of our knowledge, this is the first study for imaging depth extension of optical coherence tomography in both the anterior and posterior segments of eye by using optical clearing agents.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Anita Csorba ◽  
Erika Maka ◽  
Otto Alexander Maneschg ◽  
Attila Szabó ◽  
Nóra Szentmáry ◽  
...  

Abstract Background Presence of corneal cystine crystals is the main ocular manifestation of cystinosis, although controversial findings concerning the corneal layer with the highest density have been reported. The aim of this study was the analysis of the characteristics of crystal arrangement in different corneal layers and the assessment of corneal morphological changes with age. Methods A cross sectional study was carried out in three children and three adults who had nephropathic cystinosis and corneal cystine depositions. All patients underwent a comprehensive ophthalmological examination including best corrected distance visual acuity, slit-lamp examination, in vivo confocal microscopy and anterior segment optical coherence tomography. An evaluation of the depth of crystal deposits and crystal density in different corneal layers was also performed. Due to the low number of subjects no statistical comparison was performed. Results Anterior segment optical coherence tomography images revealed deposition of hyperreflective crystals from limbus to limbus in each patient. Crystals appeared as randomly oriented hyperreflective, elongated structures on in vivo confocal microscopy images in all corneal layers except the endothelium. In children the deposits occurred predominantly in the anterior stroma, while in adults, the crystals were mostly localized in the posterior corneal stroma with the depth of crystal deposition showing an increasing tendency with age (mean depth of crystal density was 353.17 ± 49.23 μm in children and it was 555.75 ± 25.27 μm in adults). Mean crystal density of the epithelium was 1.47 ± 1.17 (median: 1.5; interquartile range: 0.3–2.4). Mean crystal density of the anterior and posterior stroma of children and adults was 3.37 ± 0.34 (median: 3.4; interquartile range: 3.25–3.55) vs. 1.23 ± 0.23 (median: 1.2; interquartile range: 1.05–1.35) and 0.76 ± 0.49 (median: 0.7; interquartile range: 0.4–1.15) vs. 3.63 ± 0.29 (median: 3.7; interquartile range: 3.45–3.8), respectively. Endothelium had intact structure in all cases. Some hexagonal crystals were observed in two subjects. Conclusions In vivo confocal microscopy and anterior segment optical coherence tomography confirmed an age-related pattern of crystal deposition. In children, crystals tend to locate anteriorly, while in adults, deposits are found posteriorly in corneal stroma.


2018 ◽  
Vol 10 (2) ◽  
pp. 184-187
Author(s):  
Kevin Gillmann ◽  
Giorgio Enrico Bravetti ◽  
Kaweh Mansouri ◽  
André Mermoud

Introduction: The iStent inject® (Glaukos Corporation, CA, USA) is a relatively new device designed to be implanted ab-interno through the trabecular meshwork. This is, to the best of our knowledge, the first in-vivo description of a trabecular bypass device visualised with anterior segment optical coherence tomography (AS-OCT), and report of its structural effect on Schlemm’s canal. Case Report: A 74 year-old female patient suffering from long-standing primary open-angle glaucoma and nuclear sclerosis underwent cataract surgery combined with the implantation of two iStent injects®. Surgery was uncomplicated and achieved intraocular pressure (-1 mmHg) and medication (-2 molecules) reduction at 6 months. Under AS-OCT (Spectralis OCT, Heidelberg Engineering AG, Germany) the stent appears as a 300 μm long hyper reflective hollow device within the trabecular meshwork. Approximately a third of it protruded into the anterior chamber. Profound OCT signal loss was notable within the shadow of the device. A second AS-OCT section 500 μm beside the microstent shows a markedly dilated Schlemm’s canal, with a major diameter of 390 μm. Discussions: This report confirms that AS-OCT is a suitable technique to assess microstent positioning, and provides a first report on the in-vivo appearance of a functioning stent. It also indicates that iStent injects® could have a tangible effect on adjacent portions of Schlemm’s canal with, in this case, a 220% increase in canal diameter compared to the observed average (122 μm). This suggests the IOP-lowering effect of trabecular bypass devices could rely on a  dual mechanism involving Schlemm’s canal dilatation.