anterior chamber depth
Recently Published Documents


TOTAL DOCUMENTS

754
(FIVE YEARS 321)

H-INDEX

39
(FIVE YEARS 4)

2022 ◽  
Vol 15 (1) ◽  
pp. 65-70
Author(s):  
Qi-Wei Wang ◽  
◽  
Xiao-Shan Lin ◽  
Wan Chen ◽  
Qiao-Lin Zhu ◽  
...  

AIM: To assess the effectiveness of core vitrectomy-phacoemulsification-intraocular lens (IOL) implantation-capsulo-hyaloidotomy in treating phakic eye at least 1mo after the onset of malignant glaucoma. METHODS: A retrospective analysis were performed on malignant glaucoma patients treated in Zhongshan Ophthalmic Center between 2016 and 2018. Demographic and clinical data were described. The preoperative and postoperative visual acuity (VA), intraocular pressure (IOP), number of IOP-lowering medications used, and anterior chamber depth (ACD) of the case series were compared by Wilcoxon signed-rank test. RESULTS: Thirteen phakic eyes with long time intervals between onset and surgery were identified in this case series. Core vitrectomy-phacoemulsification-IOL implantation-capsulo-hyaloidotomy reduced the IOP (P=0.046) and the number of IOP-lowering medications used (P=0.004), deepened the ACD (P=0.005). Complete success was achieved in 38.5% of the eyes, and anatomical success was achieved in 100% of the eyes without any recurrence. The only postoperative complication observed is corneal endothelial decompensation. It occurred in two cases. CONCLUSION: Core vitrectomy-phacoemulsification-IOL implantation-capsulo-hyaloidotomy is safe and effective for treatment of long onset phakic malignant glaucoma.


2022 ◽  
Vol 15 (1) ◽  
pp. 52-58
Author(s):  
Rafael Vidal Merola ◽  
◽  
Artur William Veloso ◽  
Alberto Diniz-Filho ◽  
◽  
...  

AIM: To assess intraocular pressure (IOP) during the daily curve of intraocular pressure (DCPo) in keratoconic eyes and compare Goldmann applanation tonometer (GAT), without and with astigmatism correction (nGAT and cGAT) and Tono-Pen AVIA (TPA) assessment methods. METHODS: Thirty-nine keratoconic eyes of 24 patients were assessed. DCPo was evaluated with five IOP measurements; four were performed with a GAT (nGAT and cGAT), and a Tono-Pen AVIA (TPA) at various times throughout the day. RESULTS: Mean IOP DCPo values (mm Hg) were: nGAT, 9.9±2.6; cGAT, 11.3±2.6; TPA 12.3±3.1. Mean IOP DCPo differences (mm Hg) and Spearman's correlation coefficients were as follows: cGATc-nGAT, 1.32±1.31, rs=0.879 (P<0.01); cGAT-TPA, -1.02±2.08, rs=0.723 (P<0.01); and nGAT-TPA, -2.35±2.23, rs=0.730 (P<0.01). Bland-Altman analysis for agreement between cGAT-TPA and nGAT-TPA mean IOP DCPo measurements revealed a mean difference of 1.02 (95%CI, 0.35-1.70) and 2.35 (95%CI, 1.62-3.07) mm Hg, respectively. Regression analysis yielded the following equation: TPA IOP=5.49+0.775×cGAT-0.015×ACD-0.299×corneal astig matism, which allowed us to infer TPA IOP values from other parameters. CONCLUSION: In keratoconic eyes, IOP peaks of DCPo measurements are identified at 6 a.m., independent of the tonometer. The mean DCPo values are: TPA>cGAT>nGAT. IOP TPA measures are predictive of cGAT values, adjusted according to anterior chamber depth and corneal astigmatism.


2022 ◽  
Vol 19 (1) ◽  
pp. 64-68
Author(s):  
Bikram Bahadur Thapa ◽  
Basu Prasad Adhikari ◽  
Nanda Kumari Gurung ◽  
Jitendra Kumar Verma

Introduction: Proper preoperative biometry in cataract surgery provides expected postoperative uncorrected visual outcome. Astigmatism is one of the major problems to achieve best postoperative unaided visual acuity. Aims: To determine the distribution of biometric parameter and unaided visual outcome in the cataract patients operated at Nepalgunj medical college, Banke, Nepal. Methods: The patients who underwent cataract surgery between January 2019 and December 2020 at Nepalgunj medical college were studied. Patient’s demographic parameter, keratometric value, anterior chamber depth, lens thickness and axial length data, type of surgery, preoperative and post-operative visual acuity and other clinical details were collected and analyzed. Results: This study enrolled 261 eyes of 261 patients who had undergone cataract surgery. The mean age of patients was 60.8 ± 14.62 years. The mean corneal astigmatism was 1.30±1.43 D. Corneal astigmatism was higher than 1.00 D in almost 40% of cases. With-therule astigmatism was the most common type (46.4%) of astigmatism observed in this study. The mean average keratometry was 44.83±2.05 D. The mean preoperative LogMAR VA of 1.52±0.83 improved to 0.48 ± 0.48 postoperatively without statistically significant differences between manual small incision cataract surgery and phacoemulsification technique (p=0.496). Conclusion: The biometric data helps to improve surgical procedure and select most appropriate intraocular lens to attain maximal postoperative uncorrected visual acuity following cataract surgery. This study found superior convention incision is better for cataract surgery with equivalent visual outcome following manual small incision cataract surgery and phacoemulsification.


2022 ◽  
Vol 8 ◽  
Author(s):  
Qinghe Jing ◽  
Tianhui Chen ◽  
Zexu Chen ◽  
Lina Lan ◽  
Chen Zhao ◽  
...  

Purpose:To evaluate the clinical characteristics and ocular features of patients with acute secondary angle closure, associated with lens subluxation (ASAC-LS).Methods:We performed a retrospective study at the EENT Hospital of Fudan University, Shanghai, China. A total of 41 affected eyes from 41 patients were enrolled in this study. Furthermore, 20 affected eyes were part of the ASAC-LS cohort and 21 affected eyes were included in the acute primary angle closure (APAC) cohort. The best-corrected visual acuity (BCVA), intraocular pressure (IOP), axial length (AL), minimum corneal curvature (K1), maximum corneal curvature (K2), and anterior chamber depth (ACD) were measured and compared between the 2 cohorts. In addition, inter-eye (intraindividual) comparison was performed.Results:The ASAC-LS cohort exhibited younger ages, more frequent trauma history (35%), lower IOP (27.43 ± 13.86 mmHg vs. 41.27 ± 10.36 mmHg), longer AL (23.96 ± 2.60 vs. 22.49 ± 0.77 mm), shallower ACD (1.28 ± 0.38 vs. 1.58 ± 0.23 mm), and bigger ACD differences (0.99 ± 0.52 vs. 0.15 ± 0.19 mm), as compared with the APAC cohort (all p < 0.05). Moreover, eyes from the lens subluxation cohort experienced worse BCVA, higher IOP, and shallower ACD than their matched unaffected eyes (all p < 0.05). Although longer AL, shallower ACD, and bigger ACD differences were strongly correlated with lens subluxation in a univariate logistic regression analysis, only the ACD difference remained significant in the multivariate model (p = 0.004, OR = 1,510.50). Additionally, according to the receiver operating characteristic (ROC) curve analysis, both ACD and ACD differences had greater value in the differential diagnosis of ASAC-LS and APAC, with a cut-off value of 1.4 and 0.63 mm, respectively.Conclusions:Shallower ACD and larger ACD differences provide the promising diagnostic potential for patients with ASAC-LS.


2022 ◽  
Author(s):  
Mahmoud Ekram ◽  
Ahmed Mohamed Kamal Elshafei ◽  
Asmaa Anwar Mohamed ◽  
Mohamed Farouk Sayed Othman Abdelkader

Abstract Purpose: To evaluate the anatomical effects of implantable phakic contact lens (IPCL) (Care Group, India) on anterior segment and its visual outcomes .Patients and methods: In a prospective interventional case series study, 60 highly myopic eyes of 32 patients were subjected to IPCL implantation in the Ophthalmology Department of Minia University Hospital, Egypt from January 2019 to June 2021. All patients had complete ophthalmic examination and were followed up for 1 year. Pentacam was used for preoperative and postoperative estimation of anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV) and IPCL vault in the 1st, 3rd, and 12th months. Assessment of corneal endothelium was done using specular microscope preoperatively and after 12 months. Preoperative and postoperative refraction and visual acuity were measured. Results: There was a statistically significant decrease in ACD, ACA, and ACV. There was no significant difference between preoperative and postoperative mean intraocular pressure (IOP) by the 12th month (P=0.163). The mean preoperative endothelial cell count (ECD) was significantly reduced from 2929.3±248 cells/mm2 to 2737.9±303 cells/mm2 at the 12th month (P<0.001). with a statistically highly significant improvement of mean Log Mar uncorrected visual acuity (UCVA) from 1.48±0.19 preoperatively to 0.46±0.11 by the end of follow up (P<0.001) with insignificant difference between preoperative best corrected visual acuity (BCVA) and postoperative UCVA (P=0.209). In the 12th month, the mean vault was 240±540 μm. No sight threatening complications occurred.Conclusion: Although IPCL induced anatomical changes, it was safe and effective for correction of high myopia.


Animals ◽  
2022 ◽  
Vol 12 (2) ◽  
pp. 132
Author(s):  
Ahmed Abdelbaset-Ismail ◽  
Mohamed Aref ◽  
Shimaa Ezzeldein ◽  
Eslam Eisa ◽  
Mudasir Bashir Gugjoo ◽  
...  

The study investigated normal macromorphological and ultrasonographic features of the eye and lacrimal gland, as well as normal dacryocystorhinography of the donkey (Equus asinus) in Egypt. A total of 36 donkeys of different ages, weights, and sexes were included in the study: 21 live animals for ultrasonography and dacryocystorhinography, and 15 cadaver skulls for morphological anatomy of the lacrimal apparatus. The ultrasound biometric values of the eye were 33.7 ± 1.7 mm for axial globe length (AGL), 39.8 ± 2.1 mm for globe diameter (GD), 10.8 ± 0.7 mm for lens thickness (LT), 3.2 ± 0.7 mm for anterior chamber depth (ACD), and 19.3 ± 1.6 mm for vitreous chamber depth (VCD). The lacrimal gland was recognized as a hypoechogenic structure with an anechoic core, located at the dorsolateral aspect of the orbit, and ovoid in shape. The mean NLD length was 193.0 ± 9.8 mm by radiography and 206.0 ± 20.4 mm by gross assessment. One NL orifice (NLO) was noticed on each side, with a diameter of 3.0 ± 0.1 mm and located 12.1 ± 2.1 mm from the dorsal commissure of the nostril. These results may act as the baseline for proper management of conditions of the eye and lacrimal apparatus in the donkey in the future.


2022 ◽  
Vol 8 ◽  
Author(s):  
Weifen Gong ◽  
Haoyu Chen ◽  
Fan Yang ◽  
Shibin Lin ◽  
Chao Li ◽  
...  

Purpose: To evaluate the ocular biometric parameters in patients with constant and intermittent exotropia by the measurement of swept-source optical coherence tomography (SS-OCT) optical biometer OA-2000 and comparing it with the normal control subjects.Design: Cross-sectional case-control study.Participants: Fifty-five constant and 24 intermittent patients with exotropia with central fixation and 77 orthotropic normal control participants aged 4–18 years old.Methods: Non-contact and high-resolution optical biometric OA-2000 measurements were conducted under uniform ambient light conditions. The statistical analysis included intraclass correlation coefficient (ICC), Bland-Altman plot, and independent t-tests.Main Outcome Measures: Spherical equivalent (SE), ocular biological parameters such as pupil diameter (PD), anterior chamber depth (ACD), lens thickness (LT), and axial lengths (AL). The absolute values of inter-eye differences for SE, PD, ACD, LT, and AL were recorded as AnisoSE, AnisoPD, AnisoACD, AnisoLT, and AnisoAL, respectively.Results: AnisoSE (0.878 vs. 0.577, P = 0.019), AnisoAL (0.395 vs. 0.208, P = 0.001), AnisoACD (0.060 vs. 0.032, P &lt; 0.001), AnisoLT (0.060 vs. 0.031, P = 0.002), and AnisoPD (0.557 vs. 0.340, P = 0.002) were significantly larger in concomitant patients with exotropia. The SE, AL, ACD, LT, and PD showed excellent binocular correlation with ICC values that ranged from 0.943 to 0.987 in control participants and from 0.767 to 0.955 in concomitant exotropia patients. Bland-Altman plots showed the wider range of agreement in patients with concomitant exotropia than the control participants (SE: 5.0288 vs. 3.3258; AL: 2.2146 vs. 1.3172; ACD:0.3243 vs. 0.1682; PD: 2.4691 vs. 1.9241; and LT:0.3723 vs 0.1858).Conclusion: Patients with concomitant exotropia showed larger inter-eye differences in SE, ACD, LT, PD, and AL. Advice should be given to suspicious children to avoid or delay the development of concomitant exotropia.


2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Nian Guan ◽  
Xiao-Nong Zhang ◽  
Wan-Jun Zhang

Abstract Background Implantable Collamer lens (ICL) vaulting is one of the most important parameters for the safety, aqueous humor circulation, and lens transparency after ICL implantation. This study aimed to investigate the factors associated with the actual vaulting after refractive EVO-ICL surgery. Methods This retrospective study included patients who underwent EVO-ICL surgery at a tertiary eye hospital between October and December 2019. A RESCAN 700 was used for the intraoperative and CIRRUS HD-OCT was used for postoperative observation of vaulting. Subjective and objective refractions, anterior ocular segment, corneal morphology, intraocular pressure (IOP), anterior chamber volume (ACV), crystalline lens rise (CLR), white-to-white distance (WTW), anterior chamber depth (ACD), axial length, corneal endothelial cell density (ECD), and fundoscopy were examined. A multivariable analysis was performed to determine the factors independently associated with 1-month postoperative vaulting. Results Fifty-one patients (102 eyes) were included. Compared with the eyes with normal vaulting, those with high vaulting had higher preoperative diopter values (P = 0.039), lower preoperative corrected visual acuity (P = 0.006), lower preoperative IOP (P = 0.029), higher preoperative ACD (P = 0.004), lower preoperative CLR (P = 0.046), higher ICL spherical equivalent (P = 0.030), higher intraoperative vaulting (P < 0.001), and lower IOP at 1 month (P = 0.045). The multivariable analysis showed that the only factor independently associated with high vaulting at 1 month after surgery was the intraoperative vaulting value (odds ratio = 1.005, 95% confidence interval: 1.002–1.007, P < 0.001). The intraoperative and 1-month postoperative vaulting values were positively correlated (R2 = 0.562). Conclusions The RESCAN700 system can be used to perform intraoperative optical coherence tomography to predict the vaulting value of ICL at 1 month.


2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Mi Tian ◽  
Weijun Jian ◽  
Xiaoyu Zhang ◽  
Ling Sun ◽  
Yang Shen ◽  
...  

Abstract Background This study aimed to evaluate the clinical outcomes and assess preoperative characteristics that may predict outcomes in keratoconus 1 year after accelerated transepithelial corneal cross-linking (ATE-CXL). Methods This prospective study included 93 eyes of 84 consecutive keratoconus patients with 1-year follow-up after ATE-CXL. Preoperative characteristics included corneal astigmatism, anterior chamber depth, anterior chamber volume, radius of curvature, posterior elevation, central corneal thickness (CCT), thinnest corneal thickness, steepest meridian keratometry, flattest meridian keratometry, and the maximum keratometry (Kmax). Data were obtained preoperatively and at 1, 3, 6, and 12 months postoperatively. The patient eyes were grouped into 3 subgroups according to CCT and Kmax values to observe the changes of keratoconus progression. Results All patients were successfully operated without complications at any follow-up time point. Mean changes of Kmax from baseline at 6 and 12 months were − 0.60 ± 2.21 D (P = 0.011) and − 0.36 ± 1.58 D (P = 0.030), respectively. Eyes with a thinner CCT and higher Kmax values exhibited a tendency for topographic flattening of ≥1.0 D (P = 0.003; P = 0.003). In the subgroup comparison, the Kmax values decreased significantly at 6 and 12 months after ATE-CXL in the group with CCT ≤ 450 μm (P = 0.018 and P = 0.045); the Kmax values of the group with Kmax > 65.0 D decreased significantly at 6 months postoperatively (P = 0.025). Conclusion ATE-CXL is a safe and effective treatment for keratoconus patients. Patients with thinner CCT and higher Kmax values are more likely to benefit from ATE-CXL.


Sign in / Sign up

Export Citation Format

Share Document