Method of test for determination of fracture toughness in metallic materials using single edge notched tension (SENT) specimens

2014 ◽  
2009 ◽  
Vol 409 ◽  
pp. 308-312
Author(s):  
Jana Špaková ◽  
Ján Dusza

Study compare R-curve behaviour of silicon nitride obtained using Vickers indented beam specimens and single edge V-notched beam (SEVNB). R-curve measurement realized by Vickers indented beam was reported by Krause. Crack growth using single edge V-notched beam was observed in situ. The indentation experiments, in comparison with SEVNB method revealed higher R-curve values (KR=3.3 – 4.8 MPa.m1/2). The discrepancy in the R-curve results is attributed to inaccuracy related to the determination of indentation toughness. The indentation fracture toughness may include the aspects of crack opening behaviour, residual indentation stress intensity.