beam technique
Recently Published Documents


TOTAL DOCUMENTS

651
(FIVE YEARS 30)

H-INDEX

44
(FIVE YEARS 2)

Nanomaterials ◽  
2022 ◽  
Vol 12 (2) ◽  
pp. 202
Author(s):  
Miranda Martinez ◽  
Anil R. Chourasia

The Ti/SnO2 interface has been investigated in situ via the technique of x-ray photoelectron spectroscopy. Thin films (in the range from 0.3 to 1.1 nm) of titanium were deposited on SnO2 substrates via the e-beam technique. The deposition was carried out at two different substrate temperatures, namely room temperature and 200 °C. The photoelectron spectra of tin and titanium in the samples were found to exhibit significant differences upon comparison with the corresponding elemental and the oxide spectra. These changes result from chemical interaction between SnO2 and the titanium overlayer at the interface. The SnO2 was observed to be reduced to elemental tin while the titanium overlayer was observed to become oxidized. Complete reduction of SnO2 to elemental tin did not occur even for the lowest thickness of the titanium overlayer. The interfaces in both the types of the samples were observed to consist of elemental Sn, SnO2, elemental titanium, TiO2, and Ti-suboxide. The relative percentages of the constituents at the interface have been estimated by curve fitting the spectral data with the corresponding elemental and the oxide spectra. In the 200 °C samples, thermal diffusion of the titanium overlayer was observed. This resulted in the complete oxidation of the titanium overlayer to TiO2 upto a thickness of 0.9 nm of the overlayer. Elemental titanium resulting from the unreacted overlayer was observed to be more in the room temperature samples. The room temperature samples showed variation around 20% for the Ti-suboxide while an increasing trend was observed in the 200 °C samples.


Author(s):  
Michael Schöpe ◽  
Jacob Sahlmann ◽  
Kathleen Lorenz ◽  
Anne Findeisen ◽  
Thomas Barthel ◽  
...  

Materials ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 5863
Author(s):  
Katarzyna Jurek ◽  
Robert Szczesny ◽  
Marek Trzcinski ◽  
Arkadiusz Ciesielski ◽  
Jolanta Borysiuk ◽  
...  

Titanium dioxide films, about 200 nm in thickness, were deposited using the e-BEAM technique at room temperature and at 227 °C (500K) and then annealed in UHV conditions (as well as in the presence of oxygen (at 850 °C). The fabricated dielectric films were examined using X-ray powder diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, atomic force microscopy, scanning electron microscopy, transmission electron microscopy, and spectroscopic ellipsometry. The applied experimental techniques allowed us to characterize the phase composition and the phase transformation of the fabricated TiO2 coatings. The films produced at room temperature are amorphous but after annealing consist of anatase crystallites. The layers fabricated at 227 °C contain both anatase and rutile phases. In this case the anatase crystallites are accumulated near the substrate interface whilst the rutile crystallites were formed closer to the surface of the TiO2 film. It should be emphasized that these two phases of TiO2 are distinctly separated from each other.


2021 ◽  
Vol 11 ◽  
Author(s):  
Hyunsoo Jang ◽  
Jiyeon Park ◽  
Mark Artz ◽  
Yawei Zhang ◽  
Jacob C. Ricci ◽  
...  

BackgroundAlthough there are some controversies regarding whole pelvic radiation therapy (WPRT) due to its gastrointestinal and hematologic toxicities, it is considered for patients with gynecological, rectal, and prostate cancer. To effectively spare organs-at-risk (OAR) doses using multi-leaf collimator (MLC)’s optimal segments, potential dosimetric benefits in volumetric modulated arc therapy (VMAT) using a half-beam technique (HF) were investigated for WPRT.MethodsWhile the size of a fully opened field (FF) was decided to entirely include a planning target volume in all beam’s eye view across arc angles, the HF was designed to use half the FF from the isocenter for dose optimization. The left or the right half of the FF was alternatively opened in VMAT-HF using a pair of arcs rotating clockwise and counterclockwise. Dosimetric benefits of VMAT-HF, presented with dose conformity, homogeneity, and dose–volume parameters in terms of modulation complex score, were compared to VMAT optimized using the FF (VMAT-FF). Consequent normal tissue complication probability (NTCP) by reducing the irradiated volumes was evaluated as well as dose–volume parameters with statistical analysis for OAR. Moreover, beam-on time and MLC position precision were analyzed with log files to assess plan deliverability and clinical applicability of VMAT-HF as compared to VMAT-FF.ResultsWhile VMAT-HF used 60%–70% less intensity modulation complexity than VMAT-FF, it showed superior dose conformity. The small intestine and colon in VMAT-HF showed a noticeable reduction in the irradiated volumes of up to 35% and 15%, respectively, at an intermediate dose of 20–45 Gy. The small intestine showed statistically significant dose sparing at the volumes that received a dose from 15 to 45 Gy. Such a dose reduction for the small intestine and colon in VMAT-HF presented a significant NTCP reduction from that in VMAT-FF. Without sacrificing the beam delivery efficiency, VMAT-HF achieved effective OAR dose reduction in dose–volume histograms.ConclusionsVMAT-HF led to deliver conformal doses with effective gastrointestinal-OAR dose sparing despite using less modulation complexity. The dose of VMAT-HF was delivered with the same beam-on time with VMAT-FF but precise MLC leaf motions. The VMAT-HF potentially can play a valuable role in reducing OAR toxicities associated with WPRT.


2021 ◽  
Vol 130 ◽  
pp. 105810
Author(s):  
S.H. Moustafa ◽  
Gharieb A. Ali ◽  
M.I. Amer ◽  
E.R. Shaaban ◽  
M. Emam-Ismail ◽  
...  
Keyword(s):  

2021 ◽  
Vol 8 (1) ◽  
pp. 50-61
Author(s):  
Karla Leach ◽  
Shikui Tang ◽  
Jared Sturgeon ◽  
Andrew K. Lee ◽  
Ryan Grover ◽  
...  

Abstract Purpose A multi-field optimization (MFO) technique that uses beam-specific spot placement volumes (SPVs) and spot avoidance volumes (SAVs) is introduced for bilateral head and neck (H&N) cancers. These beam-specific volumes are used to guide the optimizer to consistently achieve optimal organ-at-risk (OAR) sparing with target coverage and plan robustness. Materials and Methods Implementation of this technique using a 4-beam, 5-beam, and variant 5-beam arrangement is discussed. The generation of beam-specific SPVs and SAVs derived from target and OARs are shown. The SPVs for select fields are further partitioned into optimization volumes for uniform dose distributions that resemble those of single-field optimization (SFO). A conventional MFO plan that does not use beam-specific spot placement guidance (MFOcon) and an MFO plan that uses only beam-specific SPV (MFOspv) are compared with current technique (MFOspv/sav), using both simulated scenarios and forward-calculated plans on weekly verification computed tomography (VFCT) scans. Results Dose distribution characteristics of the 4-beam, 5-beam, and variant 5-beam technique are demonstrated with discussion on OAR sparing. When comparing the MFOcon, MFOspv, and MFOspv/sav, the MFOspv/sav is shown to have superior OAR sparing in 9 of the 14 OARs examined. It also shows clinical plan robustness when evaluated by using both simulated uncertainty scenarios and forward-calculated weekly VFCTs throughout the 7-week treatment course. Conclusion The MFOspv/sav technique is a systematic approach using SPVs and SAVs to guide the optimizer to consistently reach desired OAR dose values and plan robustness.


2021 ◽  
pp. 030089162110116
Author(s):  
Raffaella Cambria ◽  
Delia Ciardo ◽  
Alessia Bazani ◽  
Floriana Pansini ◽  
Elena Rondi ◽  
...  

Objective: To compare different stereotactic body techniques—intensity-modulated radiotherapy with photons and protons, applied to radiotherapy of prostatic cancer—with simultaneous integrated boost (SIB) on the dominant intraprostatic lesion (DIL). Methods: Ten patients were selected for this planning study. Dosimetric results were compared between volumetric modulated arc therapy, intensity-modulated radiation therapy (IMRT), and intensity-modulated proton therapy both with two (IMPT 2F) and five fields (IMPT 5F) planning while applying the prescription schemes of 7.25 Gy/fraction to the prostate gland and 7.5 Gy/fraction to the DIL in 5 fractions. Results: Comparison of the coverages of the planning target volumes showed that small differences exist. The IMPT-2F-5F techniques allowed higher doses in the targets; conformal indexes resulted similar; homogeneity was better in the photon techniques (2%–5%). Regarding the organs at risk, all the techniques were able to maintain the dose well below the prescribed constraints: in the rectum, the IMPT-2F-5F and IMRT were more efficient in lowering the intermediate doses; in the bladder, the median dose was significantly better in the case of IMPT (2F–5F). In the urethra, the best sparing was achieved only by IMPT-5F. Conclusions: Stereotactic radiotherapy with SIB for localized prostate cancer is feasible with all the investigated techniques. Concerning IMPT, the two-beam technique does not seem to have a greater advantage compared to the standard techniques; the 5-beam technique seems more promising also accounting for the range uncertainty.


Author(s):  
Roberta Condò ◽  
Gianluca Mampieri ◽  
Guido Pasquantonio ◽  
Aldo Giancotti ◽  
Paola Pirelli ◽  
...  

Bacterial adhesion to the surface of the adhesive material is an important step in the formation of plaque and enamel demineralization. In order to correlate the material composition to the specific surface roughness of the resin and to the probable more favourable adhesion of bacteria, scanning electron microscopy, combined with focus ion bean micromachining, together with stylus profilometry analysis have been in vitro performed to reveal the structural nature of three orthodontic adhesive resins used for bracket bonding and, above all, to understand how compositional factors can influence specific pivotal properties such as material’s surface roughness and robustness. In particular, we speculated about the morphological features that determine an increase in the bacterial adhesion and we proposed focused ion beam technique as a valuable tool to compare the internal structures of the polymers and to determine the peculiar mechanical properties of the examined adhesive resins.


2020 ◽  
Vol 42 (12) ◽  
pp. 1659-1665
Author(s):  
O. I. Nakonechna ◽  
◽  
M. G. Dusheiko ◽  
N. N. Belyavina ◽  
A. M. Kuryliuk ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document