Faculty Opinions recommendation of Intravascular complications of central venous catheterization by insertion site.

Author(s):  
Mark Nunnally
2015 ◽  
Vol 373 (13) ◽  
pp. 1220-1229 ◽  
Author(s):  
Jean-Jacques Parienti ◽  
Nicolas Mongardon ◽  
Bruno Mégarbane ◽  
Jean-Paul Mira ◽  
Pierre Kalfon ◽  
...  

PLoS ONE ◽  
2022 ◽  
Vol 17 (1) ◽  
pp. e0261636
Author(s):  
Yasuhiro Otaki ◽  
Naofumi Fujishiro ◽  
Yasuaki Oyama ◽  
Naoko Hata ◽  
Daisuke Kato ◽  
...  

Background To prevent recurrence of medical accidents, the Medical Accident Investigating System was implemented in October 2015 by the Japan Medical Safety Research Organization (Medsafe Japan) to target deaths from medical care that were unforeseen by the administrator. Medsafe Japan analyzed the 10 cases of central venous catheterization-related deaths reported in the system and published recommendations in March 2017. However, the particular emphasis for the prevention of central venous catheterization-related deaths is unclear. Methods This study aimed to identify the recommendation points that should be emphasized to prevent recurrence of central venous catheterization-related deaths. We assessed central venous catheterization in 8530 closed-claim cases between January 2002 and December 2016 covered by the medical insurer Sompo-Japan. Moreover, we compared central venous catheterization-related death in closed-claim cases with death in reported cases. Results The background, error type, anatomic insertion site, and fatal complication data were evaluated for 37 closed-claim cases, of which 12 (32.4%) were death cases. Of the 12 closed-claim cases and 10 reported cases, 9 (75.0%) closed-claim cases and 9 (90.0%) reported cases were related to vascular access. Among these, 5 closed-claim cases (41.7%) and 7 reported cases (77.8%) were related to internal jugular vein catheterization (p = 0.28). Coagulopathy was observed in 3 (60.0%) of 5 closed-claim cases and 6 (85.7%) of 7 reported cases. Conclusions The risk of internal jugular catheterization in patients with coagulopathy must be carefully considered.


Author(s):  
Jessica M. Gonzalez-Vargas ◽  
Dailen C. Brown ◽  
Jason Z. Moore ◽  
David C. Han ◽  
Elizabeth H. Sinz ◽  
...  

The Dynamic Haptic Robotic Trainer (DHRT) was developed to minimize the up to 39% of adverse effects experienced by patients during Central Venous Catheterization (CVC) by standardizing CVC training, and provide automated assessments of performance. Specifically, this system was developed to replace manikin trainers that only simulate one patient anatomy and require a trained preceptor to evaluate the trainees’ performance. While the DHRT system provides automated feedback, the utility of this system with real-world scenarios and expertise has yet to be thoroughly investigated. Thus, the current study was developed to determine the validity of the current objective assessment metrics incorporated in the DHRT system through expert interviews. The main findings from this study are that experts do agree on perceptions of patient case difficulty, and that characterizations of patient case difficulty is based on anatomical characteristics, multiple needle insertions, and prior catheterization.


2015 ◽  
Vol 20 (4) ◽  
pp. 1061-1071 ◽  
Author(s):  
Angela Chan ◽  
Sunita Singh ◽  
Adam Dubrowski ◽  
Daniel D. Pratt ◽  
Nadia Zalunardo ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document