Cementless Total Hip Arthroplasty Using Dual Offset Titanium Tapered Stem: At Least 7-Year Follow-Up

2017 ◽  
Vol 52 (5) ◽  
pp. 419
Author(s):  
Kyung-Hoon Lee ◽  
Kee-Haeng Lee ◽  
Jongho Noh ◽  
Seong-Jun Kho
2015 ◽  
Vol 30 (6) ◽  
pp. 1014-1018 ◽  
Author(s):  
Tsutomu Kato ◽  
Takuya Otani ◽  
Hajime Sugiyama ◽  
Tetsuo Hayama ◽  
Souichi Katsumata ◽  
...  

2011 ◽  
Vol 19 (2) ◽  
pp. 169-173 ◽  
Author(s):  
Javier Sanz-Reig ◽  
Alejandro Lizaur-Utrilla ◽  
Isabel Llamas-Merino ◽  
Fernando Lopez-Prats

2010 ◽  
Vol 22 (1) ◽  
pp. 45 ◽  
Author(s):  
Ju Hyung Yoo ◽  
Sung-Guk Kim ◽  
Chang-Dong Han ◽  
Hyun Chul Oh ◽  
Han Kook Yoon

2020 ◽  
Author(s):  
Kai Zheng ◽  
Ning Li ◽  
Weicheng Zhang ◽  
Jun Zhou ◽  
Yaozeng Xu ◽  
...  

Abstract Background: Revision total hip arthroplasty is frequently accompanied by bone loss. The purpose of this study is to evaluate mid- to long-term results of revision total hip arthroplasty for massive femoral bone loss using cementless modular, fluted, tapered stems.Methods: During the period of 2007 to 2015 at a single hospital, 34 hips (33 patients) underwent primary revision surgery with cementless modular, fluted, tapered stems due to massive bone loss, and patients with prosthetic joint infection (PJI) or tumours were excluded. The hips were revised with the LINK MP (Waldemar Link, Hamburg, Germany) prosthesis. Bone loss was categorized by the Paprosky classification for prosthesis loosening and Vancouver classification for peri-prosthetic fracture. All revision bearing surfaces were ceramic-on-ceramic (CoC). Clinical outcomes, radiographic outcomes and survivorship were evaluated.Results: The mean follow-up was 9.1±2.5 years (range, 5-13 years). The Harris hip score was 43.6±11.5 preoperatively and maintained at 86.5±6.6 at the time of latest follow-up (p<0. 05). The X-ray showed bone ingrowth fixation in 30 hips (88%), fibrous stable fixation in 3 hips (9%) and instability in 1 hip (3%). The average stem subsidence was 3.9±2.2 mm (range, 1 to 10 mm). The survivorship of prostheses with re-revision for any reason was 95% (95% CI, 12.0 to 13.0) at the 10-year follow-up. Three (9%) re-revisions were needed, including 1 for aseptic loosening, 1 for dislocation and 1 for infection.Conclusions: The mid- to long-term results of revision total hip arthroplasty with the cementless modular, fluted, tapered stem (LINK MP stem) are encouraging for massive femoral bone loss.


2019 ◽  
Vol 2019 ◽  
pp. 1-6
Author(s):  
Tsan-Wen Huang ◽  
Chih-Hsiang Chang ◽  
Fu-Chun Chang ◽  
Chun-Chieh Chen ◽  
Kuo-Chin Huang ◽  
...  

Austin-Moore hemiarthroplasty (HA) had been selectively used for elderly patients with femoral neck fractures. With increasing life span and activity, the sequela of Austin-Moore HA make the implant no longer favorable. The treatment of failed Austin-Moore HA with advanced acetabular erosion is challenging; however, little has been published regarding this topic. The aim of this study was to evaluate the mid-term results of using cementless total hip arthroplasty (THA) in octogenarians. Between 2008 and 2011, 47 patients (32 women and 15 men) with an average age of 86 years (range 83-89 years) were enrolled in this retrospective study. After an average follow-up period of 6.2 years (range 5.0-7.8 years), no migration or loosening of the cup or femoral stem was found. Harris hip scores improved from 36 (range 15-42) preoperatively to 87 (range 80-90). There were no complications directly associated with the procedure except for superficial infections in two patients. Our results suggest that using cementless THA can result in favorable radiographic and clinical outcomes in octogenarian patients.


Sign in / Sign up

Export Citation Format

Share Document