scholarly journals Small Left Atrial Size Complicating Percutaneous Transcatheter Device Closure of Secundum Atrial Septal Defect with Conventional Approach

2015 ◽  
Vol 45 (3) ◽  
pp. 216
Author(s):  
Hong Ki Ko ◽  
So Yeon Kang ◽  
Jeong Jin Yu ◽  
Jae-Kon Ko ◽  
Young-Hwue Kim
2021 ◽  
Author(s):  
Xuning Lu ◽  
Ping Wen ◽  
Yuhang Liu ◽  
Quanwei Zhu

Abstract BACKGROUND Transcatheter device closure of secundum atrial septal defect (ASD) with valvular pulmonary stenosis (PS) under fluoroscopy and/or transesophageal echocardiography (TEE) guidance is a mature technology. However, little study has focused on whether the technology can be guided totally by transthoracic echocardiography (TTE), even in children.METHODS Thirteen children with ASD combined with PS underwent transcatheter device closure totally guided by TTE at our cardiac center from March 2 016 to August 2 019. Percutaneous transcatheter pulmonary valvuloplasty was performed first and then transcatheter closure of the ASD uneventfully.RESULTS All cases were successfully treated with transcatheter balloon pulmonary valvuloplasty and closure of ASD respectively via femoral vein approach solely under TTE guidance. The mean defect size was 8.1±1.4 mm (range: 5.5-10 mm), the preoperative mean pressure gradient across pulmonary valve was 61.2±5.5 mmHg (range: 51-71 mmHg). The mean device size used was 11.1±1.9 mm (range: 8- 14 mm), the mean procedure time was 55.1±8.0 min (range: 45-71 min). There were no serious cardiovascular related complications. During the follow-up period (10 mon to 47mon), no arrhythmias device, thrombosis, residual fistulas or device frame fractures were detected. PS gradient had significant difference before and after procedure during the follow up (t=28.9, P =0.000).CONCLUSION Simultaneous transcatheter treatment for ASD complicated by PS in children under TTE guidance is an safe and effective therapeutic option.


1978 ◽  
Vol 41 (2) ◽  
pp. 445
Author(s):  
Leslie E. Oliver ◽  
Dean T. Mason ◽  
Hugo Bogren ◽  
Lily George ◽  
Anthony N. DeMaria

Author(s):  
Harmeet Singh Arora ◽  
Prashant Bharadwaj ◽  
Davinder Singh Chadha ◽  
Susheel Malani ◽  
Arijit Kumar Ghosh ◽  
...  

Background: Transcatheter device closure of ostium secundum atrial septal defect is a safe & effective intervention in older children, & is usually done under transesophageal echocardiography guidance. However, the procedure under transthoracic echocardiography guidance, especially in smaller children, is done only at few centers, the data of which is scarce. Methods: A prospective study was undertaken to assess the mid-term efficacy and outcome of transcatheter device closure of ostium secundum atrial septal defect  under transthoracic echocardiographic guidance, in children <15 Kg. Results: Eighty three children with ostium secundum atrial septal defect  were included in the study. Median age of the study population was 3.5 years (1.9-5.6 years), and median weight of 11.6 Kg (7.6 - 14.9 Kg). The primary and secondary procedural success rates were 94% and 96.4% respectively. Post procedure patients were followed up for 12-30 months. Device related major complications were encountered in 4 (4.8%) cases. The total occlusion rates of the defect at 24 hours, 1 month and 3 months post procedure were 94%, 98.8% and 100% respectively. Conclusion: The transcatheter device closure of ostium secundum atrial septal defect  under transthoracic echocardiography guidance, in children <15 Kg, has a high short and mid-term safety and efficacy.


2020 ◽  
pp. 1-3
Author(s):  
Christopher Herron ◽  
Daisuke Kobayashi

Abstract Transcatheter device closure of an atrial septal defect (ASD) may require an additional supportive technique in challenging cases. We report a 15-year-old male with moderate-sized ASD and severe scoliosis. In spite of adequate positioning of the Gore Cardioform ASD occluder, the device was pulled into the right atrium by a retrieval cord due to the acute release of strong tension between the delivery catheter and its device upon locking. This phenomenon was prevented by the use of Mullins sheath, resulting in a successful release of the device. The use of a Mullins sheath may be considered to deliver a Gore Cardioform ASD device in selected cases.


2019 ◽  
Vol 41 (1) ◽  
pp. 54-61
Author(s):  
Michel Cabrera Ortega ◽  
Dunia Bárbara Benítez Ramos ◽  
Juan Carlos Ramiro Novoa ◽  
Francisco Javier Ozores Suarez ◽  
Francisco Díaz Ramírez ◽  
...  

2021 ◽  
Vol 5 (7) ◽  
Author(s):  
Rachel Hazaert ◽  
Nigel Wilson ◽  
Kathryn Rice

Abstract Background A single right coronary artery (RCA) with the left anterior descending (LAD) and circumflex coronary arteries located in the usual anatomic position and supplied by collaterals is the rarest variant of single RCA. Case summary We report a paediatric patient with an incidental finding of single RCA Lipton type RI pattern during assessment for transcatheter device closure of an ostium secundum atrial septal defect (secASD). Transthoracic echocardiography (TTE) revealed a dilated RCA, abnormal flow in the LAD, and no identifiable left main coronary artery. Diagnosis of a single RCA was confirmed with angiography. Dobutamine stress echocardiography revealed no inducible ischaemia. Transcatheter device closure of the secASD was subsequently successfully performed. Discussion TTE in paediatric patients can raise suspicion of coronary artery origin anomalies. Additional modalities, such as computed tomography and angiography, are required to comprehensively determine coronary artery anatomy. Functional assessment of ventricular function is also indicated. Coronary artery anatomy is important to delineate prior to transcatheter device closure of a secASD and should be part of the pre-procedure assessment.


Sign in / Sign up

Export Citation Format

Share Document