scholarly journals The relationship between central corneal thickness and corneal curvature in adult Nigerians

2011 ◽  
Vol 70 (1) ◽  
Author(s):  
E. Iyamu ◽  
N. M. Eze

Purpose: The aim of this study was to provide average values for central corneal thickness (CCT) and corneal curvature (CC) and also to determine a regression model for the relationship between CCT and CC in adult Nigerians without glaucoma.Methods: A total of 95 subjects consisting of 56 males and 39 females aged between 20 and 69 years with mean age of 47.1 ± 14.1 years were recruited for the study. Central corneal thickness was measured by ultrasound pachymetry (SW-1000P ultrasound pachymeter, Tianjin Suowei Electronic Technology, China) and corneal curvature was measured by keratometry (Bausch & Lomb keratometer H-135A, USA).Results: The average values of 550.1 ± 33.1µm and 43.0 ± 1.1 D were obtained for CCT and CC respectively. CCT significantly correlated with age (p=0.01), and the regression model predicts a decrease of 6.0 µm in CCT per decade. No significant association was found between CC and age (p=0.56). Also, no significant association was found between CCT and CC (p=0.07). Female subjects had significantly steeper corneas than their male counterparts.Conclusion: Central corneal thickness decreases with increasing age. Neither CCT nor age appear to be significantly correlated with corneal curvature. (S Afr Optom 2011 70(1) 44-50)

SciVee ◽  
2012 ◽  
Author(s):  
Pouya Alaghband ◽  
Evgenia Kanonidou ◽  
Laura Beltran-Agullo ◽  
Darryl R. Overby ◽  
K Sheng Lim

2019 ◽  
Vol 104 (4) ◽  
pp. 563-568 ◽  
Author(s):  
Masato Matsuura ◽  
Hiroshi Murata ◽  
Yuri Fujino ◽  
Mieko Yanagisawa ◽  
Yoshitaka Nakao ◽  
...  

AimsCorvis ST (CST) yields biomechanical corrected IOP (bIOP) which is purported to be less dependent on biomechanical properties. In our accompanied paper, it was suggested that the repeatability of bIOP is high. The purpose of the current study was to assess the relationship between intraocular pressure (IOP) measured with CST and central corneal thickness (CCT) and corneal hysteresis (CH), in comparison with IOP measured with Goldmann applanation tonometry (GAT) and the ocular response analyzer (ORA).MethodsA total of 141 eyes from 141 subjects (35 healthy eyes and 106 glaucomatous eyes) underwent IOP measurements with GAT, CST and ORA. The relationships between IOP measurements (ORA-IOPg, ORA-IOPcc, CST-bIOP and GAT IOP) and biomechanical properties (CCT, CH and corneal resistance factor (CRF)) were analysed using the linear regression analysis.ResultsIOPg, IOPcc and GAT IOP were significantly associated with CCT (p<0.001), whereas bIOP was not significantly associated with CCT (p=0.19). IOPg, bIOP and GAT IOP were significantly associated with CH (IOPg: p<0.001; bIOP: p<0.001; GAT IOP: p=0.0054), whereas IOPcc was not significantly associated with CH (p=0.18). All of IOP records were associated with CRF (p<0.001).ConclusionThe bIOP measurement from CST is independent from CCT, but dependent on CH and CRF.


Sign in / Sign up

Export Citation Format

Share Document