scholarly journals Aortic Root Replacement 42 Years after Aortic Valve Replacement with the Björk-Shiley Spherical Valve in a Patient with an Aortic Root Aneurysm

2021 ◽  
Vol 50 (3) ◽  
pp. 170-173
Author(s):  
Hidenobu Takaki ◽  
Kenichi Hashizume ◽  
Mitsuharu Mori ◽  
Masatoshi Ohno ◽  
Tomohiko Nakagawa ◽  
...  
2013 ◽  
Vol 22 (6) ◽  
pp. 734-736
Author(s):  
Tamaki Takano ◽  
Yuko Wada ◽  
Tatsuichiro Seto ◽  
Takamitsu Terasaki ◽  
Daisuke Fukui ◽  
...  

Author(s):  
Miroslav M. Furman ◽  
Sergey V. Varbanets ◽  
Oleksandr M. Dovgan

Aortic valve replacement is a gold standard in the treatment of patients with severe aortic stenosis or combined aortic pathology. However, aortic valve pathology is often associated with a narrow aortic orifice, particularly in patients with severe aortic stenosis. In 1978, Rahimtoola first described the term of prosthesis-patient mismatch. He noted that effective orifice area of the prosthesis is smaller than that of the native valve. To minimize this complication, there are several surgical strategies: aortic root enlargement (ARE), implantation of a frameless biological prosthesis in the native position, neocuspidalization procedure, Ross procedure, aortic root replacement with xenograft or homograft. ARE is an excellent option, however, some authors outline additional perioperative risks. The aim. To analyze immediate results of ARE during isolated aortic valve replacement and in cases when it is combined with other heart pathologies. Materials and methods. Our study included 63 patients who underwent ARE. Isolated aortic valve replacement was performed in the majority of cases, but often aortic root replacement procedure was combined with coronary artery bypass grafting. Results and discussion. One of 63 patients died (hospital mortality 1.6%) at an early hospital stage (30 postoperative days). Measurement of the aortic valve ring was performed by two methods, through preoperative echocardiography and perioperative measurement using a valve sizer. However, perioperative dimension was chosen as the basis for the calculations. In 62 patients, the perioperative diameter of the aortic valve ring ranged from 19 to 23 mm, only one patient had a diameter of 24 mm. According to our findings, ARE enabled to achieve an average aortic ring size increase of 2.68 cm2 (from 1.5 to 3.4 cm2) and to prevent prosthesis-patient mismatch in 42 (66.7%) cases. Conclusions. Prosthesis-patient mismatch is considered a serious complication in the postoperative period. Narrow aortic root is a common pathology that should be considered during surgery. ARE is a safe procedure and is not associated with an increased risk of mortality and complications.


2013 ◽  
Vol 16 (1) ◽  
pp. 24 ◽  
Author(s):  
ChengNan Li ◽  
YongMin Liu ◽  
RuiDong Qi ◽  
Jun Zheng ◽  
JunMing Zhu ◽  
...  

<p><b>Background:</b> Prosthetic valve detachment after aortic valve replacement and pseudoaneurysm formation are the most important postoperative complications in patients with Takayasu arteritis with aortic regurgitation. We reviewed our experience of surgical treatment of aortic regurgitation in patients with Takayasu disease.</p><p>Methods: Between November 1997 and September 2011, 11 patients (4 women and 7 men) with Takayasu arteritis with aortic regurgitation underwent surgical treatment. The age of the patients ranged from 26 to 56 years (mean, 40 � 9 years). Primary isolated aortic valve replacement was performed in 1 patient, David procedure in 1 patient, Wheat procedure in 1 patient, Bentall procedure in 2 patients, and Cabrol procedure in 6 patients (including 2 patients who underwent primary aortic valve replacement in other hospitals before being admitted to our surgical team).</p><p><b>Results:</b> There was no in-hospital death. All patients had an uneventful recovery during the postoperative course and were discharged. Prosthetic valve detachment, pseudoaneurysm formation at the suture line, and dilatation of the ascending aorta were not found in patients with composite aortic root replacement during a mean follow-up of 98 � 45 months. One patient died during follow-up.</p><p><b>Conclusion:</b> Valve detachment after composite aortic root replacement was not observed in patients with Takayasu disease with aortic regurgitation. Satisfactory surgical outcomes were obtained using composite aortic root replacement. However, close follow-up was needed to assess the effectiveness of the Cabrol procedure in patients with Takayasu disease with aortic regurgitation.</p>


Author(s):  
Christine U. Lee ◽  
James F. Glockner

72-year-old man with aortic dissection who underwent aortic root replacement and prosthetic aortic valve replacement 14 years ago; the patient has had worsening periprosthetic regurgitation and cardiac failure and has required multiple transfusions Two axial GRE images from a BOLD acquisition (Figure 7.27.1...


2008 ◽  
Vol 24 (12) ◽  
pp. S109
Author(s):  
Toshiya Okajima ◽  
Tadashi Wada ◽  
Koichi Akutsu ◽  
Tsuyoshi Yoshimuta ◽  
Shingo Sakamoto ◽  
...  

Aorta ◽  
2016 ◽  
Vol 4 ◽  
Author(s):  
Andres Enriquez Puga ◽  
Sara Castaño Rodriguez ◽  
Blanca Mateos Pañero ◽  
Beatriz Castaño Moreira ◽  
Luis F. Lopez Almodovar

Sign in / Sign up

Export Citation Format

Share Document