Femoral Neck Narrowing following Hip Resurfacing using Posterior and Ganz Approaches at Two Years

2011 ◽  
Vol 21 (5) ◽  
pp. 596-601
Author(s):  
Victoria M. Deans ◽  
Ki Wai K. Ho ◽  
Udai Prakash ◽  
Nick Parsons ◽  
Damian R. Griffin ◽  
...  
2008 ◽  
Vol 23 (8) ◽  
pp. 1105-1109 ◽  
Author(s):  
Simon Spencer ◽  
Robert Carter ◽  
Helen Murray ◽  
R.M. Dominic Meek

2011 ◽  
Vol 42 (2) ◽  
pp. 181-193 ◽  
Author(s):  
Karren M. Takamura ◽  
James Yoon ◽  
Edward Ebramzadeh ◽  
Patricia A. Campbell ◽  
Harlan C. Amstutz

2017 ◽  
Vol 25 (2) ◽  
pp. 103-106
Author(s):  
Chaturong Pornrattanamaneewong ◽  
Rapeepat Narkbunnam ◽  
Keerati Chareancholvanich

ABSTRACT Objective: To prove the accuracy of a customized guide developed according to our method. Methods: This customized guide was developed from a three-dimensional model of proximal femur reconstructed using computed tomography data. Based on the new technique, the position of the guide pin insertion was selected and adjusted using the reference of the anatomical femoral neck axis. The customized guide consists of a hemispheric covering designed to fit the posterior part of the femoral neck. The performance of the customized guide was tested in eight patients scheduled for total hip arthroplasty. The stability of the customized guide was assessed by orthopedic surgeons. An intraoperative image intensifier was used to assess the accuracy. Results: The customized guide was stabilized with full contact and was fixed in place in all patients. The mean angular deviations in relation to the what was planned in anteroposterior and lateral hip radiographs were 0.5º ± 1.8º in valgus and 1.0º ± 2.4º in retroversion, respectively. Conclusion: From this pilot test, the authors suggest that the proposed technique could be applied as a customized guide to the positioning device for hip resurfacing arthroplasty with acceptable accuracy and user-friendly interface. Level of Evidence IV, Cases Series.


2008 ◽  
Vol 18 (4) ◽  
pp. 321-323 ◽  
Author(s):  
C. Kabir ◽  
N. Sandiford ◽  
S.K. Muirhead-Allwood ◽  
T. Nuthall

We describe the case of a patient who developed a notch on the femoral neck following a hip resurfacing operation as a result of a displaced acetabular component. The acetabular cup displaced in the coronal plane and impinged on the femoral neck leading to a large notch in the inferior femoral neck.


2013 ◽  
Vol 28 (1) ◽  
pp. 147-153 ◽  
Author(s):  
Gulraj S. Matharu ◽  
Callum W. McBryde ◽  
Matthew P. Revell ◽  
Paul B. Pynsent

2011 ◽  
Vol 21 (2) ◽  
pp. 225-230 ◽  
Author(s):  
Graeme S. Carlile ◽  
Christopher P. Wakeling ◽  
Nichola Fuller ◽  
Darren Fern ◽  
Mark R. Norton

2007 ◽  
Vol 22 (7) ◽  
pp. 66-71 ◽  
Author(s):  
David R. Marker ◽  
Thorsten M. Seyler ◽  
Riyaz H. Jinnah ◽  
Ronald E. Delanois ◽  
Slif D. Ulrich ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document