scholarly journals Clinical Management of DMD-Associated Cardiomyopathy

2021 ◽  
Author(s):  
Theo Lee-Gannon ◽  
Hannah Lehrenbaum ◽  
Rahul Sheth ◽  
Pradeep P.A. Mammen

Over the past decade, cardiomyopathy has become the leading cause of mortality among patients with Duchenne muscular dystrophy (DMD). The majority of DMD patients over the age of 18 experience some degree of cardiac involvement. The primary cardiac manifestations of DMD include progressive left ventricular (LV) wall stress leading to LV dilatation and wall thinning, and the development of cardiac fibrosis, all of which culminate in decreased LV contractility and reduced cardiac output. Mortality in these patients is predominantly related to pump failure and fatal arrhythmias leading to sudden cardiac death. While basic guidelines for the management of cardiomyopathy in DMD patients exist, these recommendations are by no means comprehensive, and this chapter aims to provide further insight into appropriate clinical diagnosis and management of DMD-associated cardiomyopathy. Notably, earlier and more frequent cardiac assessment and care can allow for better outcomes for these patients. Pharmacological treatments typically include an angiotensin-converting enzyme inhibitor or angiotensin II receptor blocker, beta-adrenergic receptor blockers, mineralocorticoid receptor antagonists, and corticosteroids. Non-pharmacological therapies include automated implantable cardioverter defibrillators and left ventricular assist devices, as well as in rare cases cardiac transplantation. Additionally, many emerging therapies show great promise for improving standards of care. These novel therapies, based primarily on applied gene therapy and genome editing, have great potential to significantly alter the DMD care landscape in the near future.

2019 ◽  
Vol 3 (2) ◽  
Author(s):  
María López-Gil ◽  
Adolfo Fontenla ◽  
Juan F Delgado ◽  
Daniel Rodríguez-Muñoz

Abstract Background Left ventricular assist devices (LVAD) are increasingly used in patients with advanced heart failure, many of whom have been or will be implanted with an implantable cardioverter defibrillator (ICD). Interaction between both devices is a matter of concern. Subcutaneous ICD (S-ICD) obtains its signals through subcutaneous vectors, which poses special challenges with regards to adequate performance following LVAD implantation. Case summary We describe the case of a 24-year-old man implanted with an S-ICD because of idiopathic dilated cardiomyopathy, severe biventricular dysfunction, and self-limiting sustained ventricular tachycardias. After the implantation of a HeartMate 3™ (Left Ventricular Assist System, Abbott) several months later, the S-ICD became useless because of inappropriate sensing due to electromagnetic interference and attenuation of QRS voltage. Discussion We reviewed the reported cases in PubMed about the concomitant use of S-ICD and LVAD. Seven case reports about the performance of S-ICD in patients with an LVAD were identified, with discordant results. From these articles, we analyse the potential causes for these differing results. Pump location and operating rates in LVAD, as well as changes in the subcutaneous-electrocardiogram detected by the S-ICD after LVAD implantation are related to sensing disturbances when used in the same patient.


Sign in / Sign up

Export Citation Format

Share Document