scholarly journals Value of Sentinel Lymph Node Biopsy in Breast Cancer Surgery with Simple Pathology Facilities -An Iranian Local Experience with a Review of Potential Causes of False Negative Results

2012 ◽  
Vol 13 (11) ◽  
pp. 5385-5389 ◽  
Author(s):  
Mahasti Amoui ◽  
Mohammad Esmail Akbari ◽  
Araam Tajeddini ◽  
Nahid Nafisi ◽  
Ghasem Raziei ◽  
...  
2021 ◽  
Vol 20 (3) ◽  
Author(s):  
Loh Soon Khang ◽  
Suraya Baharudin ◽  
Juliana Abdul Latiff ◽  
Siti Aishah Mahamad Dom ◽  
Shahrun Niza Suhaimi

INTRODUCTION: Introduction: Sentinel lymph node biopsy (SLNB) is now recognized as the standard of care for early breast cancer patients with negative axillary lymph nodes. Various approaches for Sentinel Lymph Node (SLN) identification using either the blue dye method or scintigraphy alone or their combination have been proposed. However, this method is costly and may not be applicable in certain developing countries. SLNB involving the use of indocyanine green (ICG) offers several advantages, and it is valid and safe when in direct comparison with the blue dye method and scintigraphy. Hence, we performed SLNB using this method in early breast cancer as the first center that involves the use of ICG in Malaysia. We performed validation study on this method with the aims to determine its sensitivity and safety profile. MATERIALS AND METHODS: This is a validation and non-randomised prospective observational study involving 20 patients underwent SLNB wherein ICG is used for localisation. The patients were recruited according to the recommendations stipulated in the Malaysia Clinical Practice Guideline. RESULT: The average number of SLNs removed per patient was 4.0 (range, 3–6) with sentinel lymph nodes detection rate at 98.75% (79/80). The false negative rate is at 5%. No adverse events were observed in all cases. CONCLUSION: The ICG fluorescence method is simple, reliable and safe. Moreover, it demonstrates a high SLN detection rate with a low false-negative rate, and it does not require a special instrument for radioisotope use.


2007 ◽  
Vol 14 (5) ◽  
pp. 1653-1661 ◽  
Author(s):  
Roberta H. Baron ◽  
Jane V. Fey ◽  
Patrick I. Borgen ◽  
Michelle M. Stempel ◽  
Kathleen R. Hardick ◽  
...  

2021 ◽  
Vol 17 (1) ◽  
pp. 23-30
Author(s):  
Ran Song ◽  
Seong Uk Kwon ◽  
Dae Sung Yoon ◽  
In Eui Bae ◽  
In Seok Choi ◽  
...  

Purpose: Sentinel lymph node biopsy (SLNB) using both a radioactive isotope (RI) and blue dye is considered highly effective; however, there were limitations with the use of both agents in some hospitals, and blue dye has been shown to have some adverse effects. Additionally, preoperative prediction of sentinel lymph node (SLN) status using the maximum standardized uptake value (SUVmax) on positron emission tomography-computed tomography (PET-CT) can help avoid unnecessary axillary dissection or SLNB. Thus, we evaluated the efficacy and oncologic safety of SLNB using an RI alone in terms of long-term outcomes and determined the association between SLN metastasis and SUVmax of the primary tumor.Methods: This retrospective study was conducted at Konyang University Hospital between March 2011 and May 2018. Overall, 142 patients with breast cancer who underwent SLNB using an RI alone were enrolled. Data on identification and false-negative rates were collected. The SUVmax of primary tumors on PET-CT were analyzed for their association with SLN metastasis.Results: The identification and false-negative rates were 98.6% and 0%, respectively. There was no axillary local recurrence in patients with negative SLN findings. The correlation between the SUVmax of the primary tumor and SLN status was significant (r=0.249, P=0.005); the cutoff value for negative SLN metastasis was <2.15.Conclusion: The single agent method using an RI is not inferior to other methods and serves as a feasible option for SLNB. And the number of excised SLNs could be minimized when the SUVmax of primary tumor is extremely low.


Sign in / Sign up

Export Citation Format

Share Document