constant magnet
Recently Published Documents


TOTAL DOCUMENTS

3
(FIVE YEARS 2)

H-INDEX

0
(FIVE YEARS 0)

Author(s):  
I. B. Petuhov

To improve the quality of ultrasonic wire and ribbon bonding, the author propose a methodology for stabilizing the bonding force by compensating the rigidity of ultrasonic transducer (UST) mount in the ultrasonic / thermosonic bonding cycle. The author analyze the construction of ultrasonic technological systems and factors affecting the stability of the bonding process. The bonding force is controlled by an electromagnetic unit based on a coil in the field of a constant magnet, the force being directly proportional to the flowing current in the coil. The rigidity of ultrasonic transducer mount was compensated by the data obtained during the preliminary calibration of the change in the mount force over the entire UST overrun range. The calibration in this case is performed with no current flowing through the coil. The force value can be picked up from a digital force sensor. The force values are simultaneously compared with the digitized signal of the deformation sensor. The obtained data is stored in the memory of the wire bonder. In the bonding cycle, after the moment of contact is determined, the drive unit moves the bonding head vertically by the value of a predetermined distance of approximately one diameter of the bonding wire. This causes the movable part of the UST mount to rise and the force to increase. This increase is compensated by the automatic reduction of the current in the electromagnetic coil, which allows maintaining the preset force at the specified level. The bonding force during bonding is compensated in the same way, with the difference that the vector of force compensation changes – the force should increase with an increase in the deformation of the bonding wire. The implementation of the proposed algorithm made it possible to improve the bonding force stabilization to 20% when bonding thick wire, as well as to improve bonding quality. The proposed solution is also applicable in other technological ultrasound bonding systems, including bonding wire with the diameter of <100 microns.


2015 ◽  
Vol 2015 (1) ◽  
pp. 41-45
Author(s):  
Леонид Потапов ◽  
Leonid Potapov ◽  
Татьяна Сморудова ◽  
Tatyana Smorudova

Offered design of the bi-directional transaction motion generator with self-excitation without constant magnet. By means of COMSOL Multiphysics software is organized research of the distribution by magnetic flap under different positions rolling magnetic core, is brought model of the offered generator in program Electronics Workbench with determination of the voltages and current in load and winding of the generator.


Sign in / Sign up

Export Citation Format

Share Document