Membranes ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 731
Author(s):  
Ikhlass Marzouk Trifi ◽  
Lobna Chaabane ◽  
Lasâad Dammak ◽  
Lassaad Baklouti ◽  
Béchir Hamrouni

The removal of boron by Donnan dialysis from aqueous solutions has been studied according to response surface methodology (RSM). First, a preliminary study was performed with two membranes (AFN and ACS) in order to determine the experimental field based on different parameters, such as the pH of the feed compartment, the concentration of counter-ions in the receiver compartment, and the concentration of boron in the feed compartment. The best removal rate of boron was 75% with the AFN membrane, but only 48% with the ACS membrane. Then, a full-factor design was developed to determine the influence of these parameters and their interactions on the removal of boron by Donnan dialysis. The pH of the feed compartment was found to be the most important parameter. The RSM was applied according to the Doehlert model to determine the optimum conditions ([B] = 66 mg/L, pH = 11.6 and [Cl–] = 0.5 mol/L) leading to 88.8% of boron removal with an AFN membrane. The use of the RSM can be considered a good solution to determine the optimum condition for 13.8% compared to the traditional “one-at-a-time” method.


Author(s):  
Michael L. Branham ◽  
Edward A. Ross

Clearance of molecules by closed-circuit low-volume dialysis systems is limited by the accumulation of compounds in the dialysate and loss of the diffusion gradient. We sought to maintain dialysance of selected solutes by inducing “sink conditions” through the use of antibody-specific binding in the receiver compartment. Vitamin B12 was used as the test molecule since it is of clinically relevant size (molecular weight 1355 Da) and its clearance has been well-characterized for many dialyzer membranes. Using an in vitro haemodialysis model we perfused high-flux polymethylmethacrylate and low-flux polysulfone dialyzer membranes with known amounts of vitamin B12 through the intracapillary space. Clearances over time were calculated until equilibrium was reached within the fixed dialysate volume after 60 minutes. Anti-B12 monoclonal antibodies were then added to the receiver compartment reservoir. Under these sink conditions B12 clearance was restored, amounting to 77% and 118% of the integrated pre-equilibrium clearance for the high- and low-flux haemofilters, respectively. The magnitude of enhancement was such that the antibodies increased vitamin B12 clearance in low-flux dialyzers to levels observed in the high-flux devices. These studies demonstrate the feasibility of antibody-based sink conditions so as to promote substantial and highly selective solute clearance into small volume recirculating extracorporeal circuits.


Sign in / Sign up

Export Citation Format

Share Document