Optimal Optical Coherence Tomography–Based Measures in the Diagnosis of Clinically Significant Macular Edema

2007 ◽  
Vol 125 (5) ◽  
pp. 619 ◽  
Author(s):  
Robert J. Campbell
2015 ◽  
Vol 234 (3) ◽  
pp. 167-171 ◽  
Author(s):  
Tito Fiore ◽  
Marco Lupidi ◽  
Sofia Androudi ◽  
Fabrizio Giansanti ◽  
Daniela Fruttini ◽  
...  

Objective: To determine the repeatability of Spectralis optical coherence tomography (OCT) retinal thickness measurements in diabetic patients with clinically significant macular edema (CSME) using two different scanning protocols. Methods: Seventy-one eyes of 71 diabetic patients with CSME were included in the study. Coefficients of repeatability and intrasession variation coefficients were tested with 20 × 15 degree raster scans consisting of 19 or 37 high-resolution line scans (15 or 8 frames per scan, respectively) that were repeated 2 times by 1 experienced examiner. The first scan was set as the reference scan; the second scan was the follow-up scan and was performed with the use of the follow-up mode. Results: The mean and standard deviation for the central foveal subfield (CSF) using the first scanning method was 404 ± 88 μm, while it was 399 ± 86 μm using the second protocol, which was not statistically significantly different (p = 0.35, paired test). Particularly examining the CSF, the coefficient of repeatability was 1.48 (6.00 µm) and 1.49 (5.95 µm) for the 19- and the 37-B-scan acquisition, respectively, showing a nonstatistically significant difference (p < 0.001). Conclusions: Retinal thickness measurements in diabetic patients with CSME are repeatable using both scanning protocols (19 or 37 B-scans) with Spectralis OCT. The repeatability of the retinal thickness measurement does not improve by increasing the number of B-scans from 19 to 37.


Ophthalmology ◽  
2006 ◽  
Vol 113 (7) ◽  
pp. 1187.e1-1187.e12 ◽  
Author(s):  
Srinivas R. Sadda ◽  
Ou Tan ◽  
Alexander C. Walsh ◽  
Joel S. Schuman ◽  
Rohit Varma ◽  
...  

2015 ◽  
Vol 233 (3-4) ◽  
pp. 186-191 ◽  
Author(s):  
Tito Fiore ◽  
Marco Lupidi ◽  
Sofia Androudi ◽  
Fabrizio Giansanti ◽  
Daniela Fruttini ◽  
...  

Background: It was the aim of this study to compare the repeatability of Spectralis optical coherence tomography (OCT) retinal thickness measurements in healthy subjects and diabetic patients with clinically significant macular edema (CSME) with or without the use of the follow-up system. Methods: Thirty-eight eyes of 38 healthy subjects (control group) and 68 eyes of 68 diabetic patients with CSME were included in the study. The coefficient of repeatability (CR) and intrasession coefficients of variation were tested with 20 × 15 degree raster scans consisting of 19 high-resolution line scans (15 frames per scan) that were repeated 3 times by 1 experienced examiner. The first scan was set as the reference scan, whereas the second and third scans were the follow-up scans and were performed with and without the use of the follow-up mode, respectively. Results: The means and standard deviations for the central foveal subfield (CSF) in healthy subjects and diabetic patients were 289 ± 21 and 402 ± 105 μm, respectively. Particularly in diabetic patients, examining the CSF, CR was 2.67% (10.73 µm) and 6.73% (27.01 µm) with and without using the follow-up mode, respectively, and the difference was statistically significant (p < 0.05). Conclusion: These results support the hypothesis that the follow-up system improves the repeatability either in healthy subjects or in diabetic patients with poor fixation. The wider improvement in repeatability in diabetic patients in the follow-up system group compared to the no follow-up system group are probably related to poor patient fixation or eye movement in patients with CSME.


Sign in / Sign up

Export Citation Format

Share Document