Fracture of small Mitroflow® aortic bioprosthesis following valve‐in‐valve transcatheter aortic valve replacement with ACURATE neo valve—From bench testing to clinical practice

Author(s):  
Ignacio J. Amat‐Santos ◽  
Hipólito Gutiérrez ◽  
Janarthanan Sathananthan ◽  
John G Webb
2021 ◽  
Vol 14 (2) ◽  
pp. 211-220 ◽  
Author(s):  
Michel Pompeu B.O. Sá ◽  
Jef Van den Eynde ◽  
Matheus Simonato ◽  
Luiz Rafael P. Cavalcanti ◽  
Ilias P. Doulamis ◽  
...  

2021 ◽  
Vol 5 (5) ◽  
Author(s):  
Klaus-Dieter Hönemann ◽  
Steffen Hofmann ◽  
Frank Ritter ◽  
Gerold Mönnig

Abstract Background A rare, but serious, complication following transcatheter aortic valve replacement (TAVR) is the occurrence of an iatrogenic ventricular septal defect (VSD). Case summary We describe a case of an 80-year-old female who was referred with severe aortic stenosis for TAVR. Following thorough evaluation, the heart team consensus was to proceed with implantation via a transapical approach of an ACURATE neo M 25 mm valve (Boston Scientific, Natick, MA, USA). The valve was deployed harnessing transoesophageal echocardiographic (TOE) guidance under rapid pacing with post-dilation. Directly afterwards a very high VSD close to the aortic annulus was detected. As the patient was haemodynamically stable, the procedure was ended. The next day another TOE revealed a shunt volume (left-to-right ventricle) between 50% and 60%. Because the defect was partly located between the stent struts of the ACURATE valve decision was made to fix this leakage with implantation of a further valve and we chose an EVOLUT Pro 29 mm (Medtronic Inc., Minneapolis, MN, USA). The valve-in-valve was implanted 2–3 mm below the lower edge of the first valve, more towards the left ventricular outflow tract (LVOT) with excellent result: VSD was reduced to a very small residual shunt without any hemodynamic relevance. Discussion We suggest that an iatrogenic VSD located near the annulus may be treated percutaneously in a bail-out situation with implantation of a second valve that should be implanted slightly more into the LVOT to cover the VSD.


Author(s):  
Tom C. Nguyen ◽  
Alexander P. Nissen ◽  
Pranav Loyalka ◽  
Eyal E. Porat

Reoperative aortic valve replacement is associated with increased morbidity. Valve-in-valve transcatheter aortic valve replacement offers a less invasive alternative to traditional reoperation. However, cases of valve failure after valve-in-valve transcatheter aortic valve replacement represent a complex surgical challenge. We present a case requiring a complex reoperative aortic valve replacement due to structural valve deterioration after multiple previous valve-in-valve transcatheter aortic valve replacements. We performed removal of 3 previous valve-in-valve transcatheter aortic valves, bioprosthetic leaflet excision, and intentional bioprosthetic fracture under direct vision for annular enlargement. This facilitated direct insertion of a new transcatheter aortic valve for expedient and successful management of recurrent aortic stenosis in a very high-risk patient. Creative use of leaflet excision, intentional bioprosthetic fracture, and insertion of a new transcatheter aortic valve under direct vision, proved efficient and successful in a high-risk patient with few surgical options.