Effect of Design on the Performance of a Dry Powder Inhaler Using Computational Fluid Dynamics. Part 1: Grid Structure and Mouthpiece Length

2004 ◽  
Vol 93 (11) ◽  
pp. 2863-2876 ◽  
Author(s):  
Matthew S. Coates ◽  
David F. Fletcher ◽  
Hak-Kim Chan ◽  
Judy A. Raper
2006 ◽  
Vol 95 (6) ◽  
pp. 1382-1392 ◽  
Author(s):  
Matthew S. Coates ◽  
Hak-Kim Chan ◽  
David F. Fletcher ◽  
Judy A. Raper

2017 ◽  
Vol 12 (3) ◽  
pp. 249-259 ◽  
Author(s):  
Kazunori Kadota ◽  
Takuro Nishimura ◽  
Yugo Nakatsuka ◽  
Kenji Kubo ◽  
Yuichi Tozuka

Author(s):  
David F Fletcher ◽  
Vishal Chaugule ◽  
Larissa Gomes dos Reis ◽  
Paul M Young ◽  
Daniela Traini ◽  
...  

2017 ◽  
Vol 158 (3) ◽  
pp. 511-519 ◽  
Author(s):  
Elizabeth L. Perkins ◽  
Saikat Basu ◽  
Guilherme J. M. Garcia ◽  
Robert A. Buckmire ◽  
Rupali N. Shah ◽  
...  

Objectives Vocal fold granulomas are benign lesions of the larynx commonly caused by gastroesophageal reflux, intubation, and phonotrauma. Current medical therapy includes inhaled corticosteroids to target inflammation that leads to granuloma formation. Particle sizes of commonly prescribed inhalers range over 1 to 4 µm. The study objective was to use computational fluid dynamics to investigate deposition patterns over a range of particle sizes of inhaled corticosteroids targeting the larynx and vocal fold granulomas. Study Design Retrospective, case-specific computational study. Setting Tertiary academic center. Subjects/Methods A 3-dimensional anatomically realistic computational model of a normal adult airway from mouth to trachea was constructed from 3 computed tomography scans. Virtual granulomas of varying sizes and positions along the vocal fold were incorporated into the base model. Assuming steady-state, inspiratory, turbulent airflow at 30 L/min, computational fluid dynamics was used to simulate respiratory transport and deposition of inhaled corticosteroid particles ranging over 1 to 20 µm. Results Laryngeal deposition in the base model peaked for particle sizes 8 to 10 µm (2.8%-3.5%). Ideal sizes ranged over 6 to 10, 7 to 13, and 7 to 14 µm for small, medium, and large granuloma sizes, respectively. Glottic deposition was maximal at 10.8% for 9-µm-sized particles for the large posterior granuloma, 3 times the normal model (3.5%). Conclusion As the virtual granuloma size increased and the location became more posterior, glottic deposition and ideal particle size generally increased. This preliminary study suggests that inhalers with larger particle sizes, such as fluticasone propionate dry-powder inhaler, may improve laryngeal drug deposition. Most commercially available inhalers have smaller particles than suggested here.


Sign in / Sign up

Export Citation Format

Share Document