scholarly journals Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: International standards guideline statement

2010 ◽  
Vol 121 (S1) ◽  
pp. S1-S16 ◽  
Author(s):  
Gregory W. Randolph ◽  
Henning Dralle ◽  
Hisham Abdullah ◽  
Marcin Barczynski ◽  
Rocco Bellantone ◽  
...  
2018 ◽  
Vol 128 (12) ◽  
pp. 2910-2915 ◽  
Author(s):  
Whitney Liddy ◽  
Bradley R. Lawson ◽  
Samuel R. Barber ◽  
Dipti Kamani ◽  
Mohamed Shama ◽  
...  

2017 ◽  
Vol 9 (1) ◽  
pp. 1-6
Author(s):  
Rajeev Parameswaran ◽  
Gilbert Soh ◽  
James Wai Kit Lee ◽  
Oh Han Boon ◽  
Tan Wee Boon ◽  
...  

ABSTRACT Introduction Injury to the recurrent laryngeal nerve (RLN) remains a significant morbidity during thyroid and parathyroid surgery. The aim of this study is to elucidate normative RLN electromyographic (EMG) parameters. Materials and methods This is a retrospective cohort study of patients who underwent Intraoperative neuromonitoring during thyroid and parathyroid surgery from February 2014 to March 2015. The inomed C2 NerveMonitor was used. We recorded the stimulation current, amplitude, and latency of the RLN before and after nerve dissection. We also observed the number of patients who had hoarse voice after surgery. Results A total of 46 patients (14 male, 32 female) averaging 51 years old in age (20-77 years) were analyzed. The most commonly performed surgical procedure was total thyroidectomy (53.2%). The median stimulation current for both the right and left RLN was 0.500 mA. The median amplitude for the left RLN was 1.060 mV and greater than that for the right RLN (0.930 mV) (p = 0.30). The median latency for the right RLN and left RLN was 2.40 ms with no difference between the sides. (p = 0.58). Post dissection, the right RLN amplitude remained identical whereasthe left RLN amplitude decreased. Latencies of both RLNs decreased although the difference was not significant. Nature of pathology and site of surgery did not influence RLN latency and amplitude. No patients had hoarse voice. Conclusion This study highlights the normative EMG parameters for bilateral RLN nerve stimulation in an Asian population. No significant difference was noted in both pre- and postdissection RLN EMG parameters. How to cite this article Soh G, Lee JWK, Boon OH, Boon TW, Parameswaran R, Yuan NK. Experience of Intraoperative Recurrent Laryngeal Nerve monitoring in a Single Centernormative Recurrent Laryngeal Nerve Electromyographic Data. World J Endoc Surg 2017;9(1):1-6.


Author(s):  
Che-Wei Wu ◽  
Feng-Yu Chiang ◽  
Amanda Silver Karcioglu ◽  
Ayaka J. Iwata ◽  
Amr H. Abdelhamid Ahmed ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document