parathyroid surgery
Recently Published Documents


TOTAL DOCUMENTS

653
(FIVE YEARS 139)

H-INDEX

45
(FIVE YEARS 4)

Author(s):  
A Subinsha ◽  
Ripu Daman Arora
Keyword(s):  

2021 ◽  
pp. 297-304
Author(s):  
Sunnel Mattoo ◽  
Shreyamsa M ◽  
Roma Pradhan ◽  
Amit Agarwal

2021 ◽  
pp. 221-221
Author(s):  
Poongkodi Karunakaran

2021 ◽  
pp. 315-319
Author(s):  
Reetu Verma ◽  
Yogita Dwivedi
Keyword(s):  

2021 ◽  
pp. 290-296
Author(s):  
Hyeong Won Yu ◽  
June Young Choi

2021 ◽  
Vol 12 ◽  
Author(s):  
Che-Wei Wu ◽  
Tzu-Yen Huang ◽  
Gregory W. Randolph ◽  
Marcin Barczyński ◽  
Rick Schneider ◽  
...  

In the past decade, the use of intraoperative neural monitoring (IONM) in thyroid and parathyroid surgery has been widely accepted by surgeons as a useful technology for improving laryngeal nerve identification and voice outcomes, facilitating neurophysiological research, educating and training surgeons, and reducing surgical complications and malpractice litigation. Informing patients about IONM is not only good practice and helpful in promoting the efficient use of IONM resources but is indispensable for effective shared decision making between the patient and surgeon. The International Neural Monitoring Study Group (INMSG) feels complete discussion of IONM in the preoperative planning and patient consent process is important in all patients undergoing thyroid and parathyroid surgery. The purpose of this publication is to evaluate the impact of IONM on the informed consent process before thyroid and parathyroid surgery and to review the current INMSG consensus on evidence-based consent. The objective of this consensus statement, which outlines general and specific considerations as well as recommended criteria for informed consent for the use of IONM, is to assist surgeons and patients in the processes of informed consent and shared decision making before thyroid and parathyroid surgery.


2021 ◽  
pp. 000313482110611
Author(s):  
Ruhul Munshi ◽  
Nicholas Mankowski ◽  
Spenser Souza ◽  
Hosam Shalaby ◽  
Ahmed Elnahla ◽  
...  

Background Intraoperative neuromonitoring (IONM) has been accepted as a routine adjunct among surgeons who perform thyroid and parathyroid surgeries. Thyroid and parathyroid surgeries use various patient positioning strategies that have poorly understood effects on IONM. The aim of this study was to compare IONM signals between the transaxillary and transcervical approaches. Methods In this retrospective cohort study, we evaluated 463 adult patients who underwent a total of 502 procedures. The procedures performed included total thyroidectomy, right or left hemithyroidectomy, and parathyroidectomy. Vagus nerve and recurrent laryngeal nerve (RLN) latency and amplitude measurements were analyzed intra-operatively. The distances between the vagus nerve and the trachea were measured via ultrasound during transaxillary procedures. Results Compared to the transcervical approach, the right vagus nerve latency was significantly decreased in the transaxillary approach. Transaxillary surgery was not associated with increased latency or decreased amplitude on IONM. The distance between the vagus nerve and trachea was significantly decreased post-positioning during transaxillary approaches. Discussion Despite differences in patient positioning, a transaxillary approach was not associated with increased stress on the vagus nerve or RLN, according to IONM data. The decreased right vagus nerve latency associated with a transaxillary approach highlights the importance of considering patient positioning and laterality while interpreting IONM data.


2021 ◽  
Vol 10 (22) ◽  
pp. 5393
Author(s):  
Agastya Patel ◽  
Piotr Spychalski ◽  
Aleksander Aszkiełowicz ◽  
Bogusław Mikaszewski ◽  
Jarek Kobiela

Recurrent laryngeal nerve injury is an important complication following thyroid and parathyroid surgery. Recently, Transcutaneous laryngeal ultrasound (TLUSG) has emerged as a non-invasive alternative to laryngoscopic examination for vocal cord (VC) assessment. The aim of the systematic review and meta-analysis was to determine its diagnostic accuracy in reference to laryngoscopy. It was conducted in accordance with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. MEDLINE, Scopus, Cochrane library and Web of Science databases were searched to identify relevant articles. Sixteen studies were included in the review. Pooled diagnostic accuracy was calculated based on weighted arithmetic mean and plotting forest plot. The pooled visualization rate was 86.28% and 94.13% preoperatively and postoperatively, respectively. The respective pooled sensitivity and specificity was 78.48% and 98.28%, and 83.96% (CI 95%: 77.24–88.50%) and 96.15% (CI 95%: 95.24–96.88%). The diagnostic accuracy improved if transverse and lateral approaches, and valsalva maneuver were utilized. Male gender and older age were the most crucial risk factors for VC non-visualization. TLUSG is an efficacious screening tool for vocal cord palsy due to its high sensitivity. It is likely to prevent unnecessary laryngoscopic examination in around 80% of patients, with the potential for becoming a gold standard for specific (female/young) patient cohort through assimilative modifications use, increasing expertise and development of objective measurements in the future.