Quantitative assessment of brain iron by R2* relaxometry in patients with cervical dystonia

2015 ◽  
Vol 30 (10) ◽  
pp. 1422-1426 ◽  
Author(s):  
Zsuzsanna Aschermann ◽  
Gabor Perlaki ◽  
Gergely Orsi ◽  
Szilvia Anett Nagy ◽  
Andrea Horvath ◽  
...  
2009 ◽  
Vol 15 (9) ◽  
pp. 1048-1054 ◽  
Author(s):  
M Khalil ◽  
C Enzinger ◽  
C Langkammer ◽  
M Tscherner ◽  
M Wallner-Blazek ◽  
...  

Background Increased iron deposition has been implicated in the pathophysiology of multiple sclerosis (MS), based on visual analysis of signal reduction on T2-weighted images. R2* relaxometry allows to assess brain iron accumulation quantitatively. Objective To investigate regional brain iron deposition in patients with a clinically isolated syndrome (CIS) or relapsing–remitting MS (RRMS) and its associations with demographical, clinical, and conventional magnetic resonance imaging (MRI) parameters. Methods We studied 69 patients (CIS, n = 32; RRMS, n = 37) with 3T MRI and analyzed regional R2* relaxation rates and their correlations with age, disease duration, disability, T2 lesion load, and normalized brain volumes. Results Basal ganglia R2* relaxation rates increased in parallel with age ( r = 0.3–0.6; P < 0.01) and were significantly higher in RRMS than in CIS ( P < 0.05). Using multivariate linear regression analysis, the rate of putaminal iron deposition was independently predicted by the patients’ age, disease duration, and gray matter atrophy. Conclusions Quantitative assessment by R2* relaxometry suggests increased iron deposition in the basal ganglia of MS patients, which is associated with disease duration and brain atrophy. This technique together with long-term follow-up thus appears suited to clarify whether regional iron accumulation contributes to MS morbidity or merely reflects an epiphenomenon.


NeuroImage ◽  
2021 ◽  
pp. 118752
Author(s):  
Lena H.P. Vroegindeweij ◽  
Piotr A. Wielopolski ◽  
Agnita J.W. Boon ◽  
J.H. Paul Wilson ◽  
Rob M. Verdijk ◽  
...  

2010 ◽  
Vol 63 (3) ◽  
pp. 136-143 ◽  
Author(s):  
A. Burgetova ◽  
Z. Seidl ◽  
J. Krasensky ◽  
D. Horakova ◽  
M. Vaneckova

2020 ◽  
Author(s):  
José‐Carlos Delgado‐González ◽  
Carlos‐de‐la Rosa Prieto ◽  
Nuria Vallejo‐Calcerrada ◽  
Diana‐Lucía Tarruela‐Hernández ◽  
Sandra Cebada‐Sánchez ◽  
...  

VASA ◽  
2017 ◽  
Vol 46 (5) ◽  
pp. 383-388 ◽  
Author(s):  
Henrik Christian Rieß ◽  
Anna Duprée ◽  
Christian-Alexander Behrendt ◽  
Tilo Kölbel ◽  
Eike Sebastian Debus ◽  
...  

Abstract. Background: Perioperative evaluation in peripheral artery disease (PAD) by common vascular diagnostic tools is limited by open wounds, medial calcinosis or an altered collateral supply of the foot. Indocyanine green fluorescent imaging (ICG-FI) has recently been introduced as an alternative tool, but so far a standardized quantitative assessment of tissue perfusion in vascular surgery has not been performed for this purpose. The aim of this feasibility study was to investigate a new software for quantitative assessment of tissue perfusion in patients with PAD using indocyanine green fluorescent imaging (ICG-FI) before and after peripheral bypass grafting. Patients and methods: Indocyanine green fluorescent imaging was performed in seven patients using the SPY Elite system before and after peripheral bypass grafting for PAD (Rutherford III-VI). Visual and quantitative evaluation of tissue perfusion was assessed in an area of low perfusion (ALP) and high perfusion (AHP), each by three independent investigators. Data assessment was performed offline using a specially customized software package (Institute for Laser Technology, University Ulm, GmbH). Slope of fluorescent intensity (SFI) was measured as time-intensity curves. Values were compared to ankle-brachial index (ABI), slope of oscillation (SOO), and time to peak (TTP) obtained from photoplethysmography (PPG). Results: All measurements before and after surgery were successfully performed, showing that ABI, TTP, and SOO increased significantly compared to preoperative values, all being statistically significant (P < 0.05), except for TTP (p = 0.061). Further, SFI increased significantly in both ALP and AHP (P < 0.05) and correlated considerably with ABI, TTP, and SOO (P < 0.05). Conclusions: In addition to ABI and slope of oscillation (SOO), the ICG-FI technique allows visual assessment in combination with quantitative assessment of tissue perfusion in patients with PAD. Ratios related to different perfusion patterns and SFI seem to be useful tools to reduce factors disturbing ICG-FI measurements.


Sign in / Sign up

Export Citation Format

Share Document