Experimentally and analytically study on eccentrically braced frame with vertical shear links

2019 ◽  
Vol 28 (5) ◽  
pp. e1587 ◽  
Author(s):  
Mohamad G. Vetr ◽  
Ali Ghamari
2020 ◽  
Vol 35 ◽  
pp. 55-68
Author(s):  
Sara Ansari ◽  
Javad Tashakori ◽  
Javad Razzaghi

The push-over nonlinear evaluation of four eccentrically braced frame performance was conducted to assess the plastic deformation and location of plastic hinges in buildings with six, nine, twelve and fifteen stories. The excessive plastification of out-of-beam members is revealed in the majority of these buildings while the AISC design provision allows the moderate plastification in these members. Therefore, the beams out of link might be in danger of fracture of web and flange. Likewise, this was controversial evidence in Chrischurch earthquakes. In order to modify this problem either using fixed connection of braced members or using the very short shear links which have less end moment force than out-of-link beams moment strength are recommended. By this modification, the response modification coefficients are calculated for these buildings which are almost equal to the provision value. The maximum plastic rotation of shear links recommended by provisions (0.08 radian) is the upper ultimate limit to prevent emerging of out-of-link member`s instability.


2018 ◽  
Vol 2 (01) ◽  
pp. 13
Author(s):  
Reza Kurniawan ◽  
Dwi Nurtanto ◽  
Gati Annisa Hayu

Eccentrically Braced Frame (EBF) is one of several types of braces that can be used in steel building. EBF has a good stiffness and ductility to withstand earthquake load. In EBF itself there are 3 types of links, namely: Long Link, Intermediate Link, and Short Link. Meanwhile, MRF of Moment resisting Frame is a structural system where the beams and columns are connected rigidly. MRF has a good ductility in accepting load even it has no lateral braces installed. In this research the Dafam Lotus Jember hotel consisting of 10 floors with total height of 33,6 m is modeled as a MRF system structure and steel structure equipped with EBF short link. The objective of this research is to compare the effectiveness of EBF and MRF in terms of displacement, axial force, shear force, and moment occurring in buildings. The modeling results show that EBF with short link has smaller displacement value compared to MRF. The difference between the two is 86,99%. In terms of axial force, shear force, and moment, EBF has smaller values than MRF. The differences are 79,76%, 53,91%, and 10,48% respectively. These results indicate that EBF has better capacity compared to MRF. Indonesia merupakan negara yang memiliki tingkat intensitas kegempaan yang tinggi. Ini menjadikan Indonesia tidak terhindarkan dari dampak negatif yang akan ditimbulkan oleh gempa bumi, yaitu menyebabkan kerusakan insfrastruktur fisik. Peraturan gempa SNI 03-1726-2012 membahas mengenai bresing sebagai salah satu alternatif yang dapat digunakan untuk menangani masalah gempa. Eccentrically Braced Frame (EBF) adalah salah satu jenis bresing yang memiliki kekakuan dan daktilitas yang baik jika dibandingkan dengan Concentrically Braced Frame (CBF) yang hanya memiliki kekakuan yang baik. Selain itu terdapat pula Moment Resisting Frame (MRF) yaitu salah satu sistem struktur yang memiliki sifat daktail. Melihat permasalahan yang ada, maka pembahasan ini bertujuan untuk membandingkan efektivitas dari EBF menggunakan short link dengan MRF apabila diaplikasikan pada bangunan Hotel Dafam Lotus Jember 10 lantai yang memiliki tinggi 33,6 m. Adapun efektivitas yang dibadingkan disini adalah nilai story displacement dan gaya dalam (momen, gaya geser, dan gaya aksial) yang terjadi. Hasil analisa dengan bantuan program analisa struktur menunjukkan bahwa EBF menggunakan short link memiliki nilai yang lebih kecil dibandingkan dengan MRF dalam menerima beban yang bekerja. Dari segi story displacement, selisih prosentasenya adalah 86,99% sedangkan untuk gaya dalam yang meliputi momen, gaya geser, dan gaya aksial, selisihnya secara berturut-urut adalah 79,76%, 53,91% dan 10,48%. Hal ini menunjukkan bahwa EBF menggunakan short link lebih efektif jika dibandingkan dengan MRF.


2018 ◽  
Vol 2 (3) ◽  
pp. 1-13
Author(s):  
B. Rezayibana ◽  
S. Norozikalehsar ◽  
B. Nourollahi ◽  
◽  
◽  
...  

Sign in / Sign up

Export Citation Format

Share Document