Branched, dendritic, and hyperbranched polymers in liquid biopsy device design

Author(s):  
Michael J. Poellmann ◽  
Piper Rawding ◽  
DaWon Kim ◽  
Jiyoon Bu ◽  
YoungSoo Kim ◽  
...  
2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
A Chireh ◽  
R Grankvist ◽  
M Sandell ◽  
A K Mukarram ◽  
N Jaff ◽  
...  

Abstract Introduction Endomyocardial biopsy (EMB) is the gold standard for diagnosis of several cardiac diseases, yet its use is limited by low diagnostic yield and significant complication risks. The size of the current devices allows only limited steering to different parts of the ventricle walls. In transplant monitoring, repeated biopsies with the current devices can cause scarring that makes it increasingly difficult to obtain adequate samples. We hypothesised that several of the shortcomings of EMB can be avoided with a smaller and more steerable device. Further, we hypothesised that the novel sampling procedure could be coupled to a low-input molecular analysis method, such as RNA-sequencing (RNA-seq), to provide molecular characterisation of the tissue without the need of large biopsy samples. Purpose To develop an EMB device with significantly smaller dimensions, for future use in diagnostics and research investigations. Specific aims were to test feasibility and safety of the procedure, as well as the quality of the generated molecular data. Methods 65 “micro biopsy” (micro-EMB) device prototypes were designed and evaluated in-house. The prototypes were evaluated either in an ex-vivo simulator or in acute non-survival pig experiments (n=23). Once the final device design was reached, an in vivo trial was set up using six naive Yorkshire farm pigs. Micro-EMB, conventional EMB, skeletal muscle and blood samples were collected for RNA-seq characterisation and comparison. In half of the animals (n=3), micro-EMB was the only intervention in order to prioritise safety evaluations. The animals were monitored for one week. Results The final device design has an outer diameter (OD) of 0.4 mm, compared to a conventional 11 mm device (in the opened position), Fig 1A. The device can be directed to different parts of the myocardium in both ventricles. In the in vivo evaluation in swine, 81% of the biopsy attempts (n=157) were successful. High quality RNA-seq data was generated from 91% of the sequenced heart micro-biopsy samples (n=32). The gene expression signatures of samples taken with the novel device were comparable with samples taken with a conventional device, Fig 1B. No major complications were detected either during periprocedural monitoring or during the follow-up. The tissue mark after micro-biopsy was markedly smaller than after conventional endomyocardial biopsy. A) Bioptome dimensions. B) RNA-seq data. Conclusions Our preliminary data suggest that the novel submillimeter biopsy device, coupled with RNA-seq, provides a feasible method to obtain molecular data from the myocardium. The method is less traumatic and has a higher flexibility compared to conventional methods, enabling safer and more specific sampling from different parts of the myocardium. In the long term, the procedure could open unprecedented diagnostic and research possibilities. Future studies should be directed to establish the capabilities of the novel method in a relevant disease model. Acknowledgement/Funding Family Erling Persson Foundation. The Söderberg foundations. KID (Karolinska Institutet). The 4D project. Stockholm county council. Astra Zeneca.


2017 ◽  
Author(s):  
Jiyeon Ryu ◽  
Do Hyung Kim ◽  
Gyeong-Mi Kim ◽  
Jin Soo Kim ◽  
Youngkee Shin ◽  
...  

2019 ◽  
Vol 10 (05) ◽  
pp. 216-216
Author(s):  
Susanne Krome

EGFR-Tyrosinkinase-Inhibitoren (EGFR-TKI) haben zu einem Paradigmenwechsel in der Behandlungsstrategie für nicht-kleinzellige Bronchialkarzinome (NSCLC) geführt und gehören inzwischen zum Standard. Dabei ist es auch wichtig, primäre und erworbene Resistenzen zu überwinden. Eine aktuelle Studie mit 116 Patienten ergab unterschiedliche Resistenz-Mechanismen für TKI der 1./2. und der 3. Generation. Die Liquid Biopsy ist nach Ansicht der Autoren eine Option für ein nicht-invasives Monitoring der molekularen Veränderungen unter der EGFR-Therapie. Ein Review beschäftigte sich mit den Resistenzmechanismen und der Liquid Biopsy als Instrument für die Therapieplanung und -monitoring.


Pneumologie ◽  
2018 ◽  
Vol 72 (S 01) ◽  
pp. S36-S36
Author(s):  
B Schmidt ◽  
B Wollschläger ◽  
I Reindl ◽  
N Lambrecht ◽  
S Eisenmann ◽  
...  
Keyword(s):  

2018 ◽  
Vol 595 ◽  
pp. 149-156 ◽  
Author(s):  
JG Smith ◽  
D Malone ◽  
DS Baetscher ◽  
MH Carr

2018 ◽  
Author(s):  
Anna Malczewska ◽  
Beata Kos-Kudla ◽  
Pier-Luigi Filosso ◽  
Harry Aslanian ◽  
Anna Lewczuk ◽  
...  

2017 ◽  
Author(s):  
Irvin M Modlin ◽  
Mark Kidd ◽  
Ignat Drozdov ◽  
Harry Aslanian ◽  
Lisa Bodei ◽  
...  
Keyword(s):  

Sign in / Sign up