Research on Fault Diagnosis Technology of AC Medium Voltage Vacuum Circuit Breaker Based on Wavelet Packet

Author(s):  
Aijun Yang ◽  
Jiajun Guo ◽  
Sheng Xiong ◽  
Jiaming Tan ◽  
Yijun Ye ◽  
...  
2020 ◽  
Vol 187 ◽  
pp. 106502
Author(s):  
Alain Xemard ◽  
Bruno Jurisic ◽  
Michel Rioual ◽  
Arthur Olivier ◽  
Eric Sellin

2013 ◽  
Vol 321-324 ◽  
pp. 739-742
Author(s):  
Yu Huang Zheng

Vacuum circuit breaker becomes more and more complicated, integrated, high-speed and intellectualized. To insure vacuum circuit breaker in its good conditions, the function of fault diagnosis gets more important than before in the process of repairing. This paper is addressed a model-based fault detection methodology for vacuum circuit breaker. At first, the dynamic model of vacuum circuit breaker is built. Secondly, DTW algorithm is introduced to compute the similarity value between the test data and the theoretical data. At last, the value comparison between the similarity and the threshold concludes whether a fault has occurred or the vacuum circuit breaker has potential hazardous effects. The experimental results show that this method is effective.


2017 ◽  
Vol 95 ◽  
pp. 15007
Author(s):  
Xianliang Ding ◽  
Zhiming Wang ◽  
Qinlin Yin ◽  
Pengwei Chen ◽  
Shijin Zhou ◽  
...  

2019 ◽  
Vol 6 (1) ◽  
pp. 103-106
Author(s):  
B. Kühn ◽  
B. Weber ◽  
D. Gentsch ◽  
M. Kurrat

The behavior of high current arcs in vacuum circuit breaker (VCB) is interesting for research and industrial development purpose which lead to further products. To improve the interruption capability of VCB, two approaches to control the arc have been proven successful. Applying transversal magnetic fields (TMF) on the arc is use for industrial VCB in medium voltage ranges. For greater gap distances the behavior of the arc is less thoroughly investigated. <br /> In this paper, the appearance of metal vapor arcs drawn by common TMF contacts in a vacuum-test-interrupter is investigated. An adapted drive mechanism enables to interrupt a fixed current with varying gaps from 5 to 25 mm and a constant opening time. Breaking operations with a 50 Hz current are observed with a high speed camera. With increasing gap distance a changed arc appearance can be observed. The goals of this work are to be understood as a feasibility study for optical evaluation methods for vacuum arcs under TMF.


2012 ◽  
Vol 229-231 ◽  
pp. 1158-1161
Author(s):  
Yu Huang Zheng

Vacuum circuit breaker becomes more and more complicated, integrated, high-speed and intellectualized. To insure vacuum circuit breaker in its good conditions, the function of fault diagnosis gets more important than before in the process of repairing. This paper designed and developed a network fault diagnosis system based on PROFINET and B/S (Browser/Server) frame through the analysis of the need of fault diagnosis. Taking good use of testing information and diagnosis rules, the system realized open and distributed diagnosing process, and provided a flat of sharing information, which is the technique basis of combining testing and diagnosing. During design, we use Kingview as developing software. It is proved in LAN that the system can utilize present diagnosis rules in database to diagnose fault distributed.


Sign in / Sign up

Export Citation Format

Share Document